Description
[{“name”:”Standards”,”normalizedValue”:”DIN EN 50178″,”value”:”DIN EN 50178″},{“name”:”Clamping range, rated connection”,”normalizedValue”:”1.5 sq mm”,”value”:”1.5 mm²”},{“name”:”Pollution severity level”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Wire connection cross-section, finely stranded, min.”,”normalizedValue”:”0.14 mm²”,”value”:”0.14 mm²”},{“name”:”Output current derating (ohmic)”,”normalizedValue”:”6 A @ 60°C, 8 A @ 50°C”,”value”:”6 A @ 60°C, 8 A @ 50°C”},{“name”:”Status indicator”,”normalizedValue”:”Green LED”,”value”:”Green LED”},{“name”:”Storage temperature, min.”,”normalizedValue”:”-40 °C”,”value”:”-40 °C”},{“name”:”Pitch in mm (P)”,”normalizedValue”:”5 mm”,”value”:”5 mm”},{“name”:”Certificate No. (cURus)”,”normalizedValue”:”E223759″,”value”:”E223759″},{“name”:”Protection degree”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Conductor cross-section, flexible, AEH (DIN 46228-1), min.”,”normalizedValue”:”0.14 sq mm”,”value”:”0.14 mm²”},{“name”:”Connection cross-section AWG, min.”,”normalizedValue”:”AWG 26″,”value”:”AWG 26″},{“name”:”Width (inches)”,”normalizedValue”:”0.504 in”,”value”:”0.504 inch”},{“name”:”Clamping range, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Operating temperature, min.”,”normalizedValue”:”-40 °C”,”value”:”-40 °C”},{“name”:”Type of conductor”,”normalizedValue”:”rigid copper conductor, flexible copper conductor”,”value”:”rigid copper conductor, flexible copper conductor”},{“name”:”Dielectric strength, Input/Output”,”normalizedValue”:”1.2 kVeff / 5 s”,”value”:”1.2 kVeff / 5 s”},{“name”:”Wire connection cross section AWG, min.”,”normalizedValue”:”AWG 26″,”value”:”AWG 26″},{“name”:”Wire connection cross section, finely stranded, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Rated switching voltage”,”normalizedValue”:”250 V AC”,”value”:”250 V AC”},{“name”:”UL 94 flammability rating”,”normalizedValue”:”V-0″,”value”:”V-0″},{“name”:”UL File Number Search”,”normalizedValue”:”E223759″,”value”:”E223759″},{“name”:”Contact Type”,”normalizedValue”:”2 CO contact”,”value”:”2 CO contact”},{“name”:”Coil voltage of the replacement relay deviating from the rated control voltage”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Wire cross-section, finely stranded, max. (AWG)”,”normalizedValue”:”AWG 14″,”value”:”AWG 14″},{“name”:”Ambient temperature (operational), max.”,”normalizedValue”:”60 °C”,”value”:”60 °C”},{“name”:”Dielectric strength to mounting rail”,”normalizedValue”:”4 kVeff / 1 Min.”,”value”:”4 kVeff / 1 Min.”},{“name”:”Wire connection cross section AWG, max.”,”normalizedValue”:”AWG 14″,”value”:”AWG 14″},{“name”:”Pollution severity”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Wire cross-section, finely stranded, min. (AWG)”,”normalizedValue”:”AWG 26″,”value”:”AWG 26″},{“name”:”Connection cross-section AWG, max.”,”normalizedValue”:”AWG 14″,”value”:”AWG 14″},{“name”:”Depth (inches)”,”normalizedValue”:”3.457 in”,”value”:”3.457 inch”},{“name”:”Coil voltage of the replacement relay”,”normalizedValue”:”110 V DC”,”value”:”110 V DC”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.”,”normalizedValue”:”1.5 sq mm”,”value”:”1.5 mm²”},{“name”:”Twin wire-end ferrules, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Colour”,”normalizedValue”:”black”,”value”:”black”},{“name”:”Operating Temperature”,”normalizedValue”:”-40°C…60°C”,”value”:”-40°C…60°C”},{“name”:”RC filter”,”normalizedValue”:”94 Ω / 100 nF”,”value”:”94 Ω / 100 nF”},{“name”:”Protective circuit”,”normalizedValue”:”Rectifier, RC element”,”value”:”Rectifier, RC element”},{“name”:”Blade Size”,”normalizedValue”:”0.6 mm x 3.5 mm”,”value”:”0.6 x 3.5 mm”},{“name”:”Wire connection method”,”normalizedValue”:”connection”,”value”:”Tension-clamp connection”},{“name”:”Rated control voltage”,”normalizedValue”:”230 V AC± 10 %”,”value”:”230 V AC± 10 %”},{“name”:”Surge voltage category”,”normalizedValue”:”III”,”value”:”III”},{“name”:”Stripping length, rated connection”,”normalizedValue”:”8 mm”,”value”:”8 mm”},{“name”:”Wire cross-section, solid, max.”,”normalizedValue”:”2.5 mm²”,”value”:”2.5 mm²”},{“name”:”Operating temperature, max.”,”normalizedValue”:”60 deg C”,”value”:”60 °C”},{“name”:”Continuous current”,”normalizedValue”:”10A”,”value”:”10A”},{“name”:”Storage temperature, max.”,”normalizedValue”:”85 deg C”,”value”:”85 °C”},{“name”:”Rail”,”normalizedValue”:”TS 35″,”value”:”TS 35″},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.”,”normalizedValue”:”0.14 sq mm”,”value”:”0.14 mm²”},{“name”:”Impulse withstand voltage”,”normalizedValue”:”6 kV”,”value”:”6 kV (1.2/50µs)”},{“name”:”Twin wire-end ferrules, max.”,”normalizedValue”:”1 sq mm”,”value”:”1 mm²”},{“name”:”Height (inches)”,”normalizedValue”:”3.563 in”,”value”:”3.563 inch”},{“name”:”Creepage and clearance distance input to output”,”normalizedValue”:”≥5.5 mm”,”value”:”≥5.5 mm”},{“name”:”Gauge to IEC 60947-1″,”normalizedValue”:”A1, B1″,”value”:”A1, B1″},{“name”:”Dielectric strength of neighbouring contacts”,”normalizedValue”:”2.5 kVeff”,”value”:”2.5 kVeff”},{“name”:”Clamping range, min.”,”normalizedValue”:”0.14 sq mm”,”value”:”0.14 mm²”},{“name”:”Wire cross-section, solid, min.”,”normalizedValue”:”0.14 mm²”,”value”:”0.14 mm²”},{“name”:”Rated voltage”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Approvals”,”normalizedValue”:”CE, cURus, EAC”,”value”:”CE, cURus, EAC”},{“name”:”Storage temperature”,”normalizedValue”:”-40 deg C”,”value”:”-40°C…85°C”},{“name”:”Conductor cross-section, flexible, AEH (DIN 46228-1), max.”,”normalizedValue”:”1.5 sq mm”,”value”:”1.5 mm²”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.