[{“name”:”Type”,”normalizedValue”:”switching, 1 NC, NPN, PNP transistor, Relay signal [input safe-side valve component], intrinsically safe circuit, digital, output = input, direct or inverse”,”value”:”Relay, 1 NC (voltage-free), NPN, PNP transistor, switching signal [input safe-side valve component], intrinsically safe circuit, digital, output = input, direct or inverse (configurable)”},{“name”:”Height (inches)”,”normalizedValue”:”4.693 in”,”value”:”4.693 inch”},{“name”:”Device type”,”normalizedValue”:”B”,”value”:”B”},{“name”:”Storage temperature, min.”,”normalizedValue”:”-20 deg C”,”value”:”-20 °C”},{“name”:”Step response time”,”normalizedValue”:”10 ms”,”value”:”10 ms”},{“name”:”Clamping range, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”IEC Ex certificate”,”normalizedValue”:”IECEx certification”,”value”:”IECEx certification”},{“name”:”Certificate No. (ATEX)”,”normalizedValue”:”KEMA10ATEX0019X”,”value”:”KEMA10ATEX0019X”},{“name”:”Total failure rate for dangerous detected failures (λ”,”normalizedValue”:”61 FIT”,”value”:”61 FIT”},{“name”:”Residual ripple (current loop)”,”normalizedValue”:”< 40 mVeff","value":"< 40 mVeff"},{"name":"Operating Temperature","normalizedValue":"-20°C...60°C","value":"-20°C...60°C"},{"name":"Width (inches)","normalizedValue":"0.886 in","value":"0.886 inch"},{"name":"Input voltage","normalizedValue":"≤28 V DC, Trigger level low: ≤2.0 V DC (NPN), ≤8.0 V DC (PNP), Trigger level high: ≥4.0 V DC (NPN), ≥10.0 V DC (PNP)","value":"≤28 V DC, Trigger level low: ≤2.0 V DC (NPN), ≤8.0 V DC (PNP), Trigger level high: ≥4.0 V DC (NPN), ≥10.0 V DC (PNP)"},{"name":"Clamping range, rated connection","normalizedValue":"2.5 mm²","value":"2.5 mm²"},{"name":"Total failure rate for safe detected failures (λ","normalizedValue":"0 FIT","value":"0 FIT"},{"name":"Current I","normalizedValue":"≤135 mA","value":"≤135 mA"},{"name":"Insulation voltage","normalizedValue":"2.6 kV (input / output)","value":"2.6 kV (input / output)"},{"name":"Voltage U","normalizedValue":"28 V DC","value":"28 V DC"},{"name":"Demand mode","normalizedValue":"High","value":"High"},{"name":"Nominal switching voltage","normalizedValue":"≤125 V AC / 110 V DC (safe area)≤32 V AC / 32 V DC (zone 2)","value":"≤125 V AC / 110 V DC (safe area)≤32 V AC / 32 V DC (zone 2)"},{"name":"Operating temperature, min.","normalizedValue":"-20 deg C","value":"-20 °C"},{"name":"Demand rate","normalizedValue":"1,000 s","value":"1,000 s"},{"name":"Average Probability of Failure on Demand (PFD","normalizedValue":"2.92 x 10-4 (Tproof = 1 year), 4.84 x 10-4 (Tproof = 2 year), 1.06 x 10-4 (Tproof = 5 year)","value":"2.92 x 10-4 (Tproof = 1 year), 4.84 x 10-4 (Tproof = 2 year), 1.06 x 10-4 (Tproof = 5 year)"},{"name":"Tightening torque, max.","normalizedValue":"0.6 N-m","value":"0.6 Nm"},{"name":"Depth (inches)","normalizedValue":"4.472 in","value":"4.472 inch"},{"name":"Mean Time To Repair (MTTR)","normalizedValue":"24 h","value":"24 h"},{"name":"SIL in compliance with IEC 61508","normalizedValue":"2","value":"2"},{"name":"Safe Failure Fraction (SFF)","normalizedValue":"91 %","value":"91 %"},{"name":"Tightening torque, min.","normalizedValue":"0.4 N-m","value":"0.4 Nm"},{"name":"Total failure rate for dangerous undetected failures (λ","normalizedValue":"46 FIT","value":"46 FIT"},{"name":"Output values","normalizedValue":"depending on terminal assignment: 9 V @ 60 mA / 11.5 V @ 50 mA / 10 V @ 60 mA / 12.5 V @ 50 mA / 11 V @ 60 mA / 13.5 V @ 50 mA","value":"depending on terminal assignment: 9 V @ 60 mA / 11.5 V @ 50 mA / 10 V @ 60 mA / 12.5 V @ 50 mA / 11 V @ 60 mA / 13.5 V @ 50 mA"},{"name":"Voltage supply","normalizedValue":"19.2to31.2 V DC","value":"19.2to31.2 V DC"},{"name":"Diagnostic test interval","normalizedValue":"10 s","value":"10 s"},{"name":"SIL PAPER","normalizedValue":"SIL certificate","value":"SIL certificate"},{"name":"Marking","normalizedValue":"II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I","value":"II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I"},{"name":"Product information","normalizedValue":"Weidmüller provides an extended guarantee period of 36 months for this device.","value":"Weidmüller provides an extended guarantee period of 36 months for this device."},{"name":"Configuration","normalizedValue":"With FDT/DTM software","value":"With FDT/DTM software"},{"name":"Alarm function","normalizedValue":"No supply voltage, Device error","value":"No supply voltage, Device error"},{"name":"Certificate No. (IECEX)","normalizedValue":"IECEXKEM09.0071X","value":"IECEXKEM09.0071X"},{"name":"Description of the \"safe state\"","normalizedValue":"de-energized (relay output)","value":"de-energized (relay output)"},{"name":"UL File Number Search","normalizedValue":"E337701","value":"E337701"},{"name":"Power P","normalizedValue":"≤0.77 W","value":"≤0.77 W"},{"name":"Rated voltage","normalizedValue":"300 V","value":"300 V"},{"name":"EMC standards","normalizedValue":"DIN EN 61326, NE 21","value":"DIN EN 61326, NE 21"},{"name":"Number of inputs","normalizedValue":"1","value":"1"},{"name":"Wire connection cross section AWG, max.","normalizedValue":"AWG 12","value":"AWG 12"},{"name":"Output current","normalizedValue":"max. 60 mA","value":"max. 60 mA"},{"name":"Storage temperature","normalizedValue":"-20 deg C","value":"-20°C...85°C"},{"name":"Certificate no. (cULus)","normalizedValue":"E337701","value":"E337701"},{"name":"Type of connection","normalizedValue":"Screw connection","value":"Screw connection"},{"name":"Power rating","normalizedValue":"≤62.5 VA / 32 W (safe area)≤16 VA / 32 W (Zone 2)","value":"≤62.5 VA / 32 W (safe area)≤16 VA / 32 W (Zone 2)"},{"name":"Hardware fault tolerance (HFT)","normalizedValue":"0","value":"0"},{"name":"Probability of outage PFH","normalizedValue":"4.6 x 10-8 h-1","value":"4.6 x 10-8 h-1"},{"name":"Storage temperature, max.","normalizedValue":"85 deg C","value":"85 °C"},{"name":"Total failure rate for safe undetected failures (λ","normalizedValue":"480 FIT","value":"480 FIT"},{"name":"Safety category","normalizedValue":"SIL 2","value":"SIL 2"},{"name":"Protection degree","normalizedValue":"IP20","value":"IP20"},{"name":"Input resistance, voltage","normalizedValue":"3.5 kΩ","value":"3.5 kΩ"},{"name":"Humidity","normalizedValue":"0...95 % (no condensation)","value":"0...95 % (no condensation)"},{"name":"Demand response time","normalizedValue":"< 10 ms (opto output)","value":"< 10 ms (opto output)"},{"name":"Installation location","normalizedValue":"Device installed in safe area, zone 2","value":"Device installed in safe area, zone 2"},{"name":"Power consumption","normalizedValue":"≤2.5 W","value":"≤2.5 W"},{"name":"Continuous current","normalizedValue":"≤0.5 A AC / 0.3 A DC (safe zone), ≤0,5 A AC / 1 A DC (zone 2)","value":"≤0.5 A AC / 0.3 A DC (safe zone), ≤0,5 A AC / 1 A DC (zone 2)"},{"name":"Operating temperature, max.","normalizedValue":"60 deg C","value":"60 °C"},{"name":"SFF","normalizedValue":"91 %","value":"91 %"},{"name":"Wire connection cross section AWG, min.","normalizedValue":"AWG 26","value":"AWG 26"},{"name":"Clamping range, min.","normalizedValue":"0.25 sq mm","value":"0.25 mm²"},{"name":"Country of Origin (subject to change)","normalizedValue":"Denmark","value":"Denmark"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews

There are no reviews yet.

Be the first to review “Terminal Block Interface Modules Act20X-Sdi-Hdo-H-S”