Terminal Block Interface Modules Act20X-Hui-Sao-Lp-S

$518,99

Out of stock

SKU: GRG305797633 Category:

Description

[{“name”:”Type”,”normalizedValue”:”intrinsically safe circuit, Output-loop powered”,”value”:”intrinsically safe circuit, Output-loop powered”},{“name”:”Standards”,”normalizedValue”:”DIN EN 61326-1, IEC 61010-1, IEC 61010-2-030, IEC 60079-0, IEC 60079-11, IEC 60079-15, IEC 60079-26″,”value”:”DIN EN 61326-1, IEC 61010-1, IEC 61010-2-030, IEC 60079-0, IEC 60079-11, IEC 60079-15, IEC 60079-26″},{“name”:”Step response time”,”normalizedValue”:”250 msec”,”value”:”250 ms (10to90%)”},{“name”:”cUL certificate”,”normalizedValue”:”UL certification”,”value”:”UL certification”},{“name”:”Storage temperature, min.”,”normalizedValue”:”-20 °C”,”value”:”-20 °C”},{“name”:”Input resistance, voltage”,”normalizedValue”:”\u003e 10 MΩ @ 600 mV, 2 MΩ @ 28 V”,”value”:”\u003e 10 MΩ @ 600 mV, 2 MΩ @ 28 V”},{“name”:”Operating Temperature”,”normalizedValue”:”0°C…60°C”,”value”:”0°C…60°C”},{“name”:”Operating temperature, min.”,”normalizedValue”:”0 °C”,”value”:”0 °C”},{“name”:”Line resistance in measuring circuit”,”normalizedValue”:”≤50 Ω”,”value”:”≤50 Ω”},{“name”:”Power consumption”,”normalizedValue”:”≤3.5 W”,”value”:”≤3.5 W”},{“name”:”Installation location”,”normalizedValue”:”Device installed in safe area, zone 2″,”value”:”Device installed in safe area, zone 2″},{“name”:”Temperature input range”,”normalizedValue”:”Adjustable from -200…+800°C”,”value”:”Adjustable from -200…+800°C”},{“name”:”Product information”,”normalizedValue”:”Weidmüller provides an extended guarantee period of 36 months for this device.”,”value”:”Weidmüller provides an extended guarantee period of 36 months for this device.”},{“name”:”Insulation voltage”,”normalizedValue”:”3.51 kV (between input and output)”,”value”:”3.51 kV between input and output”},{“name”:”Current I”,”normalizedValue”:”88.2 mA”,”value”:”88.2 mA”},{“name”:”Rated voltage”,”normalizedValue”:”300 Veff”,”value”:”300 Veff”},{“name”:”Input resistance”,”normalizedValue”:”0to12 kΩ”,”value”:”0to12 kΩ”},{“name”:”Width (inches)”,”normalizedValue”:”0.492 in”,”value”:”0.492 inch”},{“name”:”Clamping range, min.”,”normalizedValue”:”0.25 sq mm”,”value”:”0.25 mm²”},{“name”:”Output current”,”normalizedValue”:”4 to 20 mA”,”value”:”4to20 mA (max. 23 mA)”},{“name”:”Input current”,”normalizedValue”:”configurable,± 25 mA, 0…20 mA, 4to20mA”,”value”:”configurable,± 25 mA, 0…20 mA, 4to20mA”},{“name”:”Protection degree”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Clamping range, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Cut-off frequency (-3 dB)”,”normalizedValue”:”100 Hz”,”value”:”100 Hz”},{“name”:”Accuracy”,”normalizedValue”:”\u003c 0.1 % of end value”,”value”:”\u003c 0.1 % of end value”},{“name”:”Input resistance, current”,”normalizedValue”:”70 Ω”,”value”:”70 Ω”},{“name”:”Surge voltage category”,”normalizedValue”:”III”,”value”:”III”},{“name”:”Depth (inches)”,”normalizedValue”:”4.472 in”,”value”:”4.472 inch”},{“name”:”Residual ripple (current loop)”,”normalizedValue”:”≤10 mVss”,”value”:”≤10 mVss”},{“name”:”Sensor”,”normalizedValue”:”2-/3-/4-wire, RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710, Potentiometer, Resistance: 0 – 12 kΩ”,”value”:”2-/3-/4-wire, RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710, Potentiometer, Resistance: 0 – 12 kΩ”},{“name”:”Impulse withstand voltage”,”normalizedValue”:”4 kV”,”value”:”4 kV (1.2/50µs)”},{“name”:”Marking”,”normalizedValue”:”II 3 G Ex nA IIC T4 Gc, I (M1) [Ex ia Ma] I, II (1) D [Ex ia Da] IIIC”,”value”:”II 3 G Ex nA IIC T4 Gc, I (M1) [Ex ia Ma] I, II (1) D [Ex ia Da] IIIC”},{“name”:”Power P”,”normalizedValue”:”129 mW”,”value”:”129 mW”},{“name”:”Potentiometer”,”normalizedValue”:”1.2to500 kΩ”,”value”:”1.2to500 kΩ”},{“name”:”Tightening torque, min.”,”normalizedValue”:”0.4 N-m”,”value”:”0.4 Nm”},{“name”:”Type of connection”,”normalizedValue”:”Screw connection”,”value”:”Screw connection”},{“name”:”Temperature coefficient”,”normalizedValue”:”\u003c 0.02°C of measuring range /°C”,”value”:”\u003c 0.02°C of measuring range /°C”},{“name”:”Clamping range, rated connection”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Sensor supply”,”normalizedValue”:”28to16.5 V DC / 0to20 mA”,”value”:”28to16.5 V DC / 0to20 mA”},{“name”:”Configuration”,”normalizedValue”:”With FDT/DTM software”,”value”:”With FDT/DTM software”},{“name”:”Storage temperature, max.”,”normalizedValue”:”70 deg C”,”value”:”70 °C”},{“name”:”Output signal limit”,”normalizedValue”:”3.8to20.5 mA / 0to20.5 mA (dependent on range)”,”value”:”3.8to20.5 mA / 0to20.5 mA (dependent on range)”},{“name”:”Humidity”,”normalizedValue”:”10to90 %, no condensation”,”value”:”10to90 %, no condensation”},{“name”:”Voltage supply”,”normalizedValue”:”via output current loop, 11to28 V DC (loop powered)”,”value”:”via output current loop, 11to28 V DC (loop powered)”},{“name”:”Influence of load resistance”,”normalizedValue”:”≤0.01% of span / 100 Ω”,”value”:”≤0.01% of span / 100 Ω”},{“name”:”Voltage U”,”normalizedValue”:”5.88 V DC”,”value”:”5.88 V DC”},{“name”:”Storage temperature”,”normalizedValue”:”-20 deg C”,”value”:”-20°C…70°C”},{“name”:”load impedance current”,”normalizedValue”:”≤700 Ω”,”value”:”≤700 Ω”},{“name”:”Operating temperature, max.”,”normalizedValue”:”60 deg C”,”value”:”60 °C”},{“name”:”Tightening torque, max.”,”normalizedValue”:”0.6 N-m”,”value”:”0.6 Nm”},{“name”:”Wire connection cross section AWG, min.”,”normalizedValue”:”AWG 26″,”value”:”AWG 26″},{“name”:”IEC Ex certificate”,”normalizedValue”:”IECEx certification”,”value”:”IECEx certification”},{“name”:”Height (inches)”,”normalizedValue”:”4.614 in”,”value”:”4.614 inch”},{“name”:”Wire connection cross section AWG, max.”,”normalizedValue”:”AWG 12″,”value”:”AWG 12″},{“name”:”Input voltage”,”normalizedValue”:”configurable,± 12 V DC (min. measurement range 1 V),± 28 V DC (min. measurement range 2 V),± 600 mV DC (min. measurement range 50 mV),± 150 mV DC (min. measurement range 15 mV)”,”value”:”configurable,± 12 V DC (min. measurement range 1 V),± 28 V DC (min. measurement range 2 V),± 600 mV DC (min. measurement range 50 mV),± 150 mV DC (min. measurement range 15 mV)”},{“name”:”Pollution severity”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Australia”,”value”:”Australia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Terminal Block Interface Modules Act20X-Hui-Sao-Lp-S”