Description
[{“name”:”Standards”,”normalizedValue”:”EN/IEC 60947-5-1 || UL 508 || EN/IEC 60204-32 || CSA C22.2 No 14″,”value”:”EN/IEC 60947-5-1 || UL 508 || EN/IEC 60204-32 || CSA C22.2 No 14″},{“name”:”Type Of Operator”,”normalizedValue”:”spring return”,”value”:”spring return”},{“name”:”[Ithe] Conventional Enclosed Thermal Current”,”normalizedValue”:”10A”,”value”:”10A”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Vibration Resistance”,”normalizedValue”:”15 gn 10-500 Hz)IEC 60068-2-6″,”value”:”15 gn 10-500 Hz)IEC 60068-2-6″},{“name”:”Product Compatibility”,”normalizedValue”:”XB4 || XAPS2 || XACA || XB5″,”value”:”XB4 || XAPS2 || XACA || XB5″},{“name”:”Maximum Resistance Across Terminals”,”normalizedValue”:”25 MOhm”,”value”:”25 MOhm”},{“name”:”Contact Code Designation”,”normalizedValue”:”A600 AC-15, Ue = 240 V, Ie = 3 A IEC 947-5-1 appendix A || A600 AC-15, Ue = 600 V, Ie = 1.2 A IEC 947-5-1 appendix A || Q600 DC-13, Ue = 250 V, Ie = 0.27 A IEC 947-5-1 appendix A || Q600 DC-13, Ue = 600 V, Ie = 0.1 A IEC 947-5-1 appendix A”,”value”:”A600 AC-15, Ue = 240 V, Ie = 3 A IEC 947-5-1 appendix A || A600 AC-15, Ue = 600 V, Ie = 1.2 A IEC 947-5-1 appendix A || Q600 DC-13, Ue = 250 V, Ie = 0.27 A IEC 947-5-1 appendix A || Q600 DC-13, Ue = 600 V, Ie = 0.1 A IEC 947-5-1 appendix A”},{“name”:”Product Or Component Type”,”normalizedValue”:”contact block”,”value”:”contact block”},{“name”:”Mounting Of Block”,”normalizedValue”:”front mounting”,”value”:”front mounting”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV IEC 60947-1″,”value”:”6 kV IEC 60947-1″},{“name”:”Terminals Description Iso N°1″,”normalizedValue”:”(13-14)NO”,”value”:”(13-14)NO”},{“name”:”Contact Block Application”,”normalizedValue”:”single speed”,”value”:”single speed”},{“name”:”Component Name”,”normalizedValue”:”ZB2″,”value”:”ZB2″},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25-70°C”,”value”:”-25-70°C”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”600 V 3)IEC 60947-1″,”value”:”600 V 3)IEC 60947-1″},{“name”:”Contact Operation”,”normalizedValue”:”slow-break”,”value”:”slow-break”},{“name”:”Electrical Circuit Type”,”normalizedValue”:”control circuit”,”value”:”control circuit”},{“name”:”Operating Force”,”normalizedValue”:”13-15 N”,”value”:”13-15 N”},{“name”:”Electrical Shock Protection Class”,”normalizedValue”:”class II IEC 61140″,”value”:”class II IEC 61140″},{“name”:”Rated Operational Power In W”,”normalizedValue”:”40 W DC-13 1000000 cycles 3600 cyc/h 120 V 0.5 IEC 60947-5-1 || 48 W DC-13 1000000 cycles 3600 cyc/h 48 V 0.5 IEC 60947-5-1 || 65 W DC-13 1000000 cycles 3600 cyc/h 24 V 0.5 IEC 60947-5-1″,”value”:”40 W DC-13 1000000 cycles 3600 cyc/h 120 V 0.5 IEC 60947-5-1 || 48 W DC-13 1000000 cycles 3600 cyc/h 48 V 0.5 IEC 60947-5-1 || 65 W DC-13 1000000 cycles 3600 cyc/h 24 V 0.5 IEC 60947-5-1″},{“name”:”Mechanical Durability”,”normalizedValue”:”1,000,000 cycle”,”value”:”1000000 cycles”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”1 NO”,”value”:”1 NO”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamps terminals, 1 x 2.5 mm² with or without cable end || screw clamps terminals, 2 x 1.5 mm² with or without cable end”,”value”:”screw clamps terminals, 1 x 2.5 mm² with or without cable end || screw clamps terminals, 2 x 1.5 mm² with or without cable end”},{“name”:”Contact Block Type”,”normalizedValue”:”single”,”value”:”single”},{“name”:”Short-Circuit Protection”,”normalizedValue”:”10 A fuse protection cartridge gG (gl)”,”value”:”10 A fuse protection cartridge gG (gl)”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Unknown”,”value”:”Unknown”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.