Description
[{“name”:”Type”,”normalizedValue”:”MAK 2.5″,”value”:”MAK 2.5″},{“name”:”Standards”,”normalizedValue”:”IEC 60947-7-1 (-7-2)”,”value”:”IEC 60947-7-1 (-7-2)”},{“name”:”Material”,”normalizedValue”:”PA 66″,”value”:”PA 66″},{“name”:”Wire connection cross section, finely stranded with wire-end ferrules DIN 46228/1, 2 clampable wires, max.”,”normalizedValue”:”0.75 sq mm”,”value”:”0.75 mm²”},{“name”:”Width (inches)”,”normalizedValue”:”0.244 in”,”value”:”0.244 inch”},{“name”:”Wire cross section max. (CSA)”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Voltage size D (UR)”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Number of connections”,”normalizedValue”:”7″,”value”:”7″},{“name”:”Voltage size D (CSA)”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Number of potentials”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Wire connection cross section, solid core, min. rated connection”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules and plastic collars DIN 46228/4, rated connection, max.”,”normalizedValue”:”2.5 mm²”,”value”:”2.5 mm²”},{“name”:”No. of clamping points per level”,”normalizedValue”:”2″,”value”:”2″},{“name”:”End cover plate required”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Clamping range, rated connection, min.”,”normalizedValue”:”0.13 mm²”,”value”:”0.13 mm²”},{“name”:”Rated current”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Wire connection cross section, solid core max. rated connection”,”normalizedValue”:”4 mm²”,”value”:”4 mm²”},{“name”:”Conductor size Factory wiring min. (UR)”,”normalizedValue”:”26 AWG”,”value”:”26 AWG”},{“name”:”Conductor size Factory wiring max. (UR)”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Clamping screw”,”normalizedValue”:”M 2.5″,”value”:”M 2.5″},{“name”:”Clamping range, rated connection, max.”,”normalizedValue”:”4 mm²”,”value”:”4 mm²”},{“name”:”Pollution severity”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Depth (inches)”,”normalizedValue”:”2.48 in”,”value”:”2.48 inch”},{“name”:”Conductor size Field wiring max. (UR)”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Height (inches)”,”normalizedValue”:”3.465 in”,”value”:”3.465 inch”},{“name”:”Voltage size C (CSA)”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Version”,”normalizedValue”:”Screw connection, With PE connection, One end without connector”,”value”:”Screw connection, With PE connection, One end without connector”},{“name”:”Gauge to IEC 60947-1″,”normalizedValue”:”A3″,”value”:”A3″},{“name”:”Rated voltage”,”normalizedValue”:”500 V”,”value”:”500 V”},{“name”:”Certificate No. (UR)”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Conductor size Field wiring min. (UR)”,”normalizedValue”:”22 AWG”,”value”:”22 AWG”},{“name”:”Open sides”,”normalizedValue”:”right”,”value”:”right”},{“name”:”Depth including DIN rail”,”normalizedValue”:”64 mm”,”value”:”64 mm”},{“name”:”Stripping length”,”normalizedValue”:”8 mm”,”value”:”8 mm”},{“name”:”Installation advice”,”normalizedValue”:”Direct mounting”,”value”:”Direct mounting”},{“name”:”Current size B (CSA)”,”normalizedValue”:”10 A”,”value”:”10A”},{“name”:”Mounting rail”,”normalizedValue”:”TS 35″,”value”:”TS 35″},{“name”:”Wire cross section min. (CSA)”,”normalizedValue”:”26 AWG”,”value”:”26 AWG”},{“name”:”Current at maximum wires”,”normalizedValue”:”31 A”,”value”:”31 A”},{“name”:”Wire connection cross section, finely stranded, max.”,”normalizedValue”:”4 sq mm”,”value”:”4 mm²”},{“name”:”Surge voltage category”,”normalizedValue”:”III”,”value”:”III”},{“name”:”Current size D (CSA)”,”normalizedValue”:”10 A”,”value”:”10A”},{“name”:”Wire connection cross-section, finely stranded, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Type of connection”,”normalizedValue”:”Screw connection”,”value”:”Screw connection”},{“name”:”Wire connection cross section, finely stranded with wire-end ferrules DIN 46228/1, 2 clampable wires, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Current size D (UR)”,”normalizedValue”:”10A”,”value”:”10A”},{“name”:”Type of mounting”,”normalizedValue”:”Snap-on”,”value”:”Snap-on”},{“name”:”PE function”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Wire connection cross section, stranded, rated connection, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Connection direction”,”normalizedValue”:”on side”,”value”:”on side”},{“name”:”Wire cross-section, finely stranded, two clampable wires, max.”,”normalizedValue”:”1 sq mm”,”value”:”1 mm²”},{“name”:”Blade Size”,”normalizedValue”:”0.6 mm x 3.5 mm”,”value”:”0.6 x 3.5 mm”},{“name”:”Wire connection cross section, finely stranded with wire-end ferrules DIN 46228/1, rated connection, max.”,”normalizedValue”:”2.5 mm²”,”value”:”2.5 mm²”},{“name”:”Volume resistance according to IEC 60947-7-x”,”normalizedValue”:”3.99 milliohm”,”value”:”3.99 mΩ”},{“name”:”Wire connection cross section, stranded, rated connection, max.”,”normalizedValue”:”4 mm²”,”value”:”4 mm²”},{“name”:”Rated impulse withstand voltage”,”normalizedValue”:”6 kV”,”value”:”6 kV”},{“name”:”Current size C (CSA)”,”normalizedValue”:”10 A”,”value”:”10A”},{“name”:”Wire connection cross section, finely stranded with wire-end ferrules DIN 46228/1, rated connection, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Tightening torque, min.”,”normalizedValue”:”0.4 N-m”,”value”:”0.4 Nm”},{“name”:”Rated cross-section”,”normalizedValue”:”2.5 mm²”,”value”:”2.5 mm²”},{“name”:”Colour”,”normalizedValue”:”beige, yellow”,”value”:”beige / yellow”},{“name”:”UL File Number Search”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Tightening torque, max.”,”normalizedValue”:”0.6 N-m”,”value”:”0.6 Nm”},{“name”:”UL 94 flammability rating”,”normalizedValue”:”V-2″,”value”:”V-2″},{“name”:”Number of Levels”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Continuous operating temp., max.”,”normalizedValue”:”100 deg C”,”value”:”100 °C”},{“name”:”Continuous operating temp., min.”,”normalizedValue”:”-50 deg C”,”value”:”-50 °C”},{“name”:”Number of potentials per tier”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Wire connection cross section, finely stranded, two clampable wires, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Cross-section for connected conductor, finely stranded with wire-end ferrules and plastic collars DIN 46228/4, rated connection, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Certificate No. (CSA)”,”normalizedValue”:”12,400 to 320″,”value”:”12400-320″},{“name”:”Voltage size B (CSA)”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”PE connection”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Approvals”,”normalizedValue”:”UR, CSA, CE, EAC”,”value”:”UR, CSA, CE, EAC”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Unknown”,”value”:”Unknown”},{“name”:”Package Quantity”,”normalizedValue”:”50″,”value”:”50″}]

Reviews
There are no reviews yet.