Terminal And Contact Block, 100PK

$193,99

33

Out of stock

SKU: GRG704297529 Category:

Description

[{“name”:”Material”,”normalizedValue”:”Wemid”,”value”:”Wemid”},{“name”:”Standards”,”normalizedValue”:”IEC 60947-7-1″,”value”:”IEC 60947-7-1″},{“name”:”Wire connection cross section AWG, min.”,”normalizedValue”:”AWG 28″,”value”:”AWG 28″},{“name”:”Depth (inches)”,”normalizedValue”:”1.437 in”,”value”:”1.437 inch”},{“name”:”UL 94 flammability rating”,”normalizedValue”:”V-0″,”value”:”V-0″},{“name”:”Current size B (CSA)”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”UL File Number Search”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Blade Size”,”normalizedValue”:”0.6 mm x 3.5 mm”,”value”:”0.6 x 3.5 mm”},{“name”:”Conductor size Factory wiring min. (cURus)”,”normalizedValue”:”28 AWG”,”value”:”28 AWG”},{“name”:”Colour”,”normalizedValue”:”dark beige”,”value”:”dark beige”},{“name”:”Wire connection cross-section, solid core, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Voltage size D (CSA)”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Voltage size B (CSA)”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Voltage size B (cURus)”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Conductor size Field wiring min. (cURus)”,”normalizedValue”:”28 AWG”,”value”:”28 AWG”},{“name”:”PE function”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Stripping length”,”normalizedValue”:”10 mm”,”value”:”10 mm”},{“name”:”Current size C (cURus)”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Voltage size C (CSA)”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Wire cross section max. (IECEX)”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Wire cross section max. (ATEX)”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Wire connection cross-section, solid core, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Clamping range, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Installation advice”,”normalizedValue”:”Rail”,”value”:”Rail”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Open sides”,”normalizedValue”:”right”,”value”:”right”},{“name”:”Current at maximum wires”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Max. voltage (ATEX)”,”normalizedValue”:”550 V”,”value”:”550 V”},{“name”:”Twin wire-end ferrules, max.”,”normalizedValue”:”0.75 sq mm”,”value”:”0.75 mm²”},{“name”:”Volume resistance according to IEC 60947-7-x”,”normalizedValue”:”1.33 milliohm”,”value”:”1.33 mΩ”},{“name”:”Height (inches)”,”normalizedValue”:”2.165 in”,”value”:”2.165 inch”},{“name”:”Number of potentials”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Rated voltage”,”normalizedValue”:”800 V”,”value”:”800 V”},{“name”:”Rated impulse withstand voltage”,”normalizedValue”:”8 kV”,”value”:”8 kV”},{“name”:”Wire cross section min. (CSA)”,”normalizedValue”:”28 AWG”,”value”:”28 AWG”},{“name”:”Type of connection”,”normalizedValue”:”PUSH IN”,”value”:”PUSH IN”},{“name”:”Certificate No. (CSA)”,”normalizedValue”:”200,039 to 70,089,609″,”value”:”200039-70089609″},{“name”:”Number of potentials per tier”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Continuous operating temp., max.”,”normalizedValue”:”130 deg C”,”value”:”130 °C”},{“name”:”Certificate No. (cURus)”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Max. voltage (IECEX)”,”normalizedValue”:”550 V”,”value”:”550 V”},{“name”:”Pollution severity”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Conductor size Field wiring max. (cURus)”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”PE connection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Storage temperature, min.”,”normalizedValue”:”10 deg C”,”value”:”10 °C”},{“name”:”Wire connection cross section, finely stranded, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Current (ATEX)”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Wire connection cross section AWG, max.”,”normalizedValue”:”AWG 12″,”value”:”AWG 12″},{“name”:”Number of connections”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Power loss in accordance with IEC 60947-7-x”,”normalizedValue”:”0.77 W”,”value”:”0.77 W”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Current size C (CSA)”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Current size D (cURus)”,”normalizedValue”:”5 A”,”value”:”5A”},{“name”:”Depth including DIN rail”,”normalizedValue”:”37 mm”,”value”:”37 mm”},{“name”:”Voltage size D (cURus)”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Connection direction”,”normalizedValue”:”top”,”value”:”top”},{“name”:”Clamping range, min.”,”normalizedValue”:”0.14 sq mm”,”value”:”0.14 mm²”},{“name”:”Connection cross-section, stranded, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Twin wire-end ferrules, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Wire cross section max. (CSA)”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Conductor size Factory wiring max. (cURus)”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Current (IECEX)”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Colour of operational elements”,”normalizedValue”:”orange”,”value”:”orange”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Number of Levels”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Number of clamping points per level”,”normalizedValue”:”2″,”value”:”2″},{“name”:”End cover plate required”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Rail”,”normalizedValue”:”TS 35″,”value”:”TS 35″},{“name”:”Marking EN 60079-7″,”normalizedValue”:”Ex eb II C Gb”,”value”:”Ex eb II C Gb”},{“name”:”Storage temperature, max.”,”normalizedValue”:”40 deg C”,”value”:”40 °C”},{“name”:”Rated cross-section”,”normalizedValue”:”2.5 mm²”,”value”:”2.5 mm²”},{“name”:”Continuous operating temp., min.”,”normalizedValue”:”-60 deg C”,”value”:”-60 °C”},{“name”:”Approvals”,”normalizedValue”:”BURVER, CE, CSA, cURus, DNV GL, EAC, IECEXTUR, TUEVNATEX”,”value”:”BURVER, CE, CSA, cURus, DNV GL, EAC, IECEXTUR, TUEVNATEX”},{“name”:”Connection cross-section, stranded, min.”,”normalizedValue”:”0.5 sq mm”,”value”:”0.5 mm²”},{“name”:”Width (inches)”,”normalizedValue”:”0.201 in”,”value”:”0.201 inch”},{“name”:”Wire connection cross-section, finely stranded, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Certificate No. (ATEX)”,”normalizedValue”:”TUEV16ATEX7909U”,”value”:”TUEV16ATEX7909U”},{“name”:”Type of mounting”,”normalizedValue”:”TS 35″,”value”:”TS 35″},{“name”:”Storage temperature”,”normalizedValue”:”10 deg C”,”value”:”10°C…40°C”},{“name”:”Voltage size C (cURus)”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Certificate No. (IECEX)”,”normalizedValue”:”IECEXTUR16.0036U”,”value”:”IECEXTUR16.0036U”},{“name”:”Current size B (cURus)”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Surge voltage category”,”normalizedValue”:”III”,”value”:”III”},{“name”:”Gauge to IEC 60947-1″,”normalizedValue”:”A3″,”value”:”A3″},{“name”:”Rated current”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Type of fixing”,”normalizedValue”:”Snap-on”,”value”:”Snap-on”},{“name”:”Current size D (CSA)”,”normalizedValue”:”5 A”,”value”:”5A”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Unknown”,”value”:”Unknown”},{“name”:”Package Quantity”,”normalizedValue”:”100″,”value”:”100″}]

Reviews

There are no reviews yet.

Be the first to review “Terminal And Contact Block, 100PK”