Description
[{“name”:”Item”,”normalizedValue”:”TeSys GV2 Manual Starter and Protector,”,”value”:”TeSys GV2 Manual Starter and Protector,”},{“name”:”Width”,”normalizedValue”:”45 mm”,”value”:”45 mm”},{“name”:”Standards”,”normalizedValue”:”EN/IEC 60947-2 || EN/IEC 60947-4-1″,”value”:”EN/IEC 60947-2 || EN/IEC 60947-4-1″},{“name”:”Color”,”normalizedValue”:”Dark Grey”,”value”:”dark grey”},{“name”:”Depth”,”normalizedValue”:”78.5 mm”,”value”:”78.5 mm”},{“name”:”Height”,”normalizedValue”:”101 mm”,”value”:”101 mm”},{“name”:”Operating Altitude”,”normalizedValue”:”6561.68 ft (2000 m)”,”value”:”6561.68 ft (2000 m)”},{“name”:”Ik Degree Of Protection”,”normalizedValue”:”IK04″,”value”:”IK04″},{“name”:”Mechanical Robustness”,”normalizedValue”:”shocks 30 Gn for 11 ms || vibrations 5 Gn, 5…150 Hz”,”value”:”shocks 30 Gn for 11 ms || vibrations 5 Gn, 5…150 Hz”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz IEC 60947-4-1″,”value”:”50/60 Hz IEC 60947-4-1″},{“name”:”Power Dissipation Per Pole”,”normalizedValue”:”2.5 W”,”value”:”2.5 W”},{“name”:”Rated Duty”,”normalizedValue”:”continuous IEC 60947-4-1″,”value”:”continuous IEC 60947-4-1″},{“name”:”Product Or Component Type”,”normalizedValue”:”motor circuit breaker”,”value”:”motor circuit breaker”},{“name”:”Control Type”,”normalizedValue”:”push-button”,”value”:”push-button”},{“name”:”Trip Unit Technology”,”normalizedValue”:”thermal-magnetic”,”value”:”thermal-magnetic”},{“name”:”Product Name”,”normalizedValue”:”TeSys GV2 || TeSys Deca”,”value”:”TeSys GV2 || TeSys Deca”},{“name”:”Climatic Withstand”,”normalizedValue”:”IACS E10″,”value”:”IACS E10″},{“name”:”Network Type”,”normalizedValue”:”AC”,”value”:”AC”},{“name”:”Phase Failure Sensitivity”,”normalizedValue”:”yes IEC 60947-4-1″,”value”:”yes IEC 60947-4-1″},{“name”:”Suitability For Isolation”,”normalizedValue”:”yes IEC 60947-1 § 7-1-6″,”value”:”yes IEC 60947-1 § 7-1-6″},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 IEC 60529″,”value”:”IP20 IEC 60529″},{“name”:”Motor Power Kw”,”normalizedValue”:”0.75-0.75 kW 400/415 V AC 50/60 Hz || 1.1-1.1 kW 500 V AC 50/60 Hz”,”value”:”0.75-0.75 kW 400/415 V AC 50/60 Hz || 1.1-1.1 kW 500 V AC 50/60 Hz”},{“name”:”Fire Resistance”,”normalizedValue”:”960 °C IEC 60695-2-11″,”value”:”960 °C IEC 60695-2-11″},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV IEC 60947-2″,”value”:”6 kV IEC 60947-2″},{“name”:”Mechanical Durability”,”normalizedValue”:”100000 cycles”,”value”:”100000 cycles”},{“name”:”[Ith] Conventional Free Air Thermal Current”,”normalizedValue”:”2.5 A IEC 60947-4-1″,”value”:”2.5 A IEC 60947-4-1″},{“name”:”Line Rated Current”,”normalizedValue”:”2.5 A”,”value”:”2.5 A”},{“name”:”Device Application”,”normalizedValue”:”motor protection”,”value”:”motor protection”},{“name”:”Fixing Mode”,”normalizedValue”:”35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)”,”value”:”35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)”},{“name”:”[Ics] Rated Service Short-Circuit Breaking Capacity”,”normalizedValue”:”100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 75 % 690 V AC 50/60 Hz IEC 60947-2″,”value”:”100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 75 % 690 V AC 50/60 Hz IEC 60947-2″},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-60 °C”,”value”:”-20-60 °C”},{“name”:”Product Certifications”,”normalizedValue”:”CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA”,”value”:”CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-80 °C”,”value”:”-40-80 °C”},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”690 V AC 50/60 Hz IEC 60947-2″,”value”:”690 V AC 50/60 Hz IEC 60947-2″},{“name”:”Utilisation Category”,”normalizedValue”:”category A IEC 60947-2 || AC-3 IEC 60947-4-1″,”value”:”category A IEC 60947-2 || AC-3 IEC 60947-4-1″},{“name”:”Thermal Protection Adjustment Range”,”normalizedValue”:”1.6-2.5 A IEC 60947-4-1″,”value”:”1.6-2.5 A IEC 60947-4-1″},{“name”:”Device Short Name”,”normalizedValue”:”GV2ME”,”value”:”GV2ME”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”690 V AC 50/60 Hz IEC 60947-2″,”value”:”690 V AC 50/60 Hz IEC 60947-2″},{“name”:”Magnetic Tripping Current”,”normalizedValue”:”33.5-33.5 A”,”value”:”33.5-33.5 A”},{“name”:”Range”,”normalizedValue”:”TeSys Deca”,”value”:”TeSys Deca”},{“name”:”Breaking Capacity”,”normalizedValue”:”100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2″,”value”:”100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2″},{“name”:”Poles Description”,”normalizedValue”:”3P”,”value”:”3P”},{“name”:”Electrical Durability”,”normalizedValue”:”100000 cycles AC-3 415 V In”,”value”:”100000 cycles AC-3 415 V In”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.