TeSys Deca control relay – 3 NO + 2 NC – <= 690 V - 600 V AC standard coil

$86,95

Relay 600V 10Amp Tesys + Options

9999 in stock

SKU: GRG0847920 Category:

Description

[{“name”:”Coil Volts”,”normalizedValue”:”600 V”,”rank”:2,”value”:”600V”},{“name”:”Item”,”normalizedValue”:”Relay 600V 10Amp Tesys + Options”,”value”:”Relay 600V 10Amp Tesys + Options”},{“name”:”Height”,”normalizedValue”:”77 mm”,”value”:”77 mm”},{“name”:”Width”,”normalizedValue”:”45 mm”,”value”:”45 mm”},{“name”:”Standards”,”normalizedValue”:”EN/IEC 60947-5-1 || GB/T 14048.5 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || JIS C8201-5-1″,”value”:”EN/IEC 60947-5-1 || GB/T 14048.5 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || JIS C8201-5-1″},{“name”:”Depth”,”normalizedValue”:”84 mm”,”value”:”84 mm”},{“name”:”Contactor Application”,”normalizedValue”:”control circuit”,”value”:”control circuit”},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”\u003c= 690 V AC 25…400 Hz”,”value”:”\u003c= 690 V AC 25…400 Hz”},{“name”:”Product Certifications”,”normalizedValue”:”CB Scheme || CCC || UL || CSA || EAC || CE || UKCA”,”value”:”CB Scheme || CCC || UL || CSA || EAC || CE || UKCA”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”600 V UL || 600 V CSA || 690 V IEC 60947-5-1″,”value”:”600 V UL || 600 V CSA || 690 V IEC 60947-5-1″},{“name”:”Non-Overlap Time”,”normalizedValue”:”1.5 ms on energisation between NC and NO contact || 1.5 ms on de-energisation between NC and NO contact”,”value”:”1.5 ms on energisation between NC and NO contact || 1.5 ms on de-energisation between NC and NO contact”},{“name”:”Tightening Torque”,”normalizedValue”:”1.2 N.m screw clamp terminals Philips No 2 || 1.2 N.m screw clamp terminals flat Ø 6 mm || 1.2 N.m screw clamp terminals pozidriv No 2″,”value”:”1.2 N.m screw clamp terminals Philips No 2 || 1.2 N.m screw clamp terminals flat Ø 6 mm || 1.2 N.m screw clamp terminals pozidriv No 2″},{“name”:”Irms Rated Making Capacity”,”normalizedValue”:”140 A AC IEC 60947-5-1 || 250 A DC IEC 60947-5-1″,”value”:”140 A AC IEC 60947-5-1 || 250 A DC IEC 60947-5-1″},{“name”:”Utilisation Category”,”normalizedValue”:”AC-14 || AC-15 || DC-13″,”value”:”AC-14 || AC-15 || DC-13″},{“name”:”[Ith] Conventional Free Air Thermal Current”,”normalizedValue”:”10 A 60°C”,”value”:”10 A 60°C”},{“name”:”Device Short Name”,”normalizedValue”:”CAD”,”value”:”CAD”},{“name”:”Mounting Support”,”normalizedValue”:”rail || plate”,”value”:”rail || plate”},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”600 V AC 50/60 Hz”,”value”:”600 V AC 50/60 Hz”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-40-60°C || 60-70°C with derating”,”value”:”-40-60°C || 60-70°C with derating”},{“name”:”Protective Treatment”,”normalizedValue”:”TH IEC 60068″,”value”:”TH IEC 60068″},{“name”:”Product Or Component Type”,”normalizedValue”:”control relay”,”value”:”control relay”},{“name”:”Mechanical Durability”,”normalizedValue”:”30 Mcycles”,”value”:”30 Mcycles”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-60-80°C”,”value”:”-60-80°C”},{“name”:”[Icw] Rated Short-Time Withstand Current”,”normalizedValue”:”100 A – 1 s || 120 A – 500 ms || 140 A – 100 ms”,”value”:”100 A – 1 s || 120 A – 500 ms || 140 A – 100 ms”},{“name”:”Insulation Resistance”,”normalizedValue”:”\u003e 10 MOhm”,”value”:”\u003e 10 MOhm”},{“name”:”Product Name”,”normalizedValue”:”TeSys CAD”,”value”:”TeSys CAD”},{“name”:”Hold-In Power Consumption In Va”,”normalizedValue”:”8-8 VA 50 Hz 20°C)”,”value”:”8-8 VA 50 Hz 20°C)”},{“name”:”Control Circuit Type”,”normalizedValue”:”AC 50/60 Hz”,”value”:”AC 50/60 Hz”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”0.3…0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8…1.1 Uc -40-60°C operational AC 50 Hz || 0.85…1.1 Uc -40-60°C operational AC 60 Hz || 1…1.1 Uc 60-70°C operational AC 50/60 Hz”,”value”:”0.3…0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8…1.1 Uc -40-60°C operational AC 50 Hz || 0.85…1.1 Uc -40-60°C operational AC 60 Hz || 1…1.1 Uc 60-70°C operational AC 50/60 Hz”},{“name”:”Operating Time”,”normalizedValue”:”12…22 ms coil energisation and NO closing || 4…12 ms coil de-energisation and NO opening || 4…19 ms coil energisation and NC opening || 6…17 ms coil de-energisation and NC closing”,”value”:”12…22 ms coil energisation and NO closing || 4…12 ms coil de-energisation and NO opening || 4…19 ms coil energisation and NC opening || 6…17 ms coil de-energisation and NC closing”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP2X front face VDE 0106″,”value”:”IP2X front face VDE 0106″},{“name”:”Range”,”normalizedValue”:”TeSys || TeSys Deca”,”value”:”TeSys || TeSys Deca”},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG IEC 60947-5-1″,”value”:”10 A gG IEC 60947-5-1″},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA”,”value”:”5 mA”},{“name”:”Maximum Operating Rate”,”normalizedValue”:”180 cyc/mn”,”value”:”180 cyc/mn”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminals 1 1-4 mm²flexible without cable end || screw clamp terminals 2 1-4 mm²flexible without cable end || screw clamp terminals 1 1-4 mm²flexible with cable end || screw clamp terminals 2 1-2.5 mm²flexible with cable end || screw clamp terminals 1 1-4 mm²solid without cable end || screw clamp terminals 2 1-4 mm²solid without cable end”,”value”:”screw clamp terminals 1 1-4 mm²flexible without cable end || screw clamp terminals 2 1-4 mm²flexible without cable end || screw clamp terminals 1 1-4 mm²flexible with cable end || screw clamp terminals 2 1-2.5 mm²flexible with cable end || screw clamp terminals 1 1-4 mm²solid without cable end || screw clamp terminals 2 1-4 mm²solid without cable end”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V”,”value”:”17 V”},{“name”:”Pole Contact Composition”,”normalizedValue”:”3 NO + 2 NC”,”value”:”3 NO + 2 NC”},{“name”:”Inrush Power In Va”,”normalizedValue”:”70-70 VA 50 Hz 20°C)”,”value”:”70-70 VA 50 Hz 20°C)”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV IEC 60947″,”value”:”6 kV IEC 60947″},{“name”:”Operating Altitude”,”normalizedValue”:”0…9842.52 ft (0…3000 m)”,”value”:”0…9842.52 ft (0…3000 m)”},{“name”:”Mechanical Robustness”,”normalizedValue”:”shocks control relay open10 Gn for 11 ms IEC 60068-2-27 || shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 || vibrations control relay open2 Gn, 5…300 Hz IEC 60068-2-6 || vibrations control relay closed4 Gn, 5…300 Hz IEC 60068-2-6″,”value”:”shocks control relay open10 Gn for 11 ms IEC 60068-2-27 || shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 || vibrations control relay open2 Gn, 5…300 Hz IEC 60068-2-6 || vibrations control relay closed4 Gn, 5…300 Hz IEC 60068-2-6″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “TeSys Deca control relay – 3 NO + 2 NC – <= 690 V - 600 V AC standard coil”