Description
[{“name”:”Coil Volts”,”normalizedValue”:”600 V”,”rank”:2,”value”:”600V”},{“name”:”Item”,”normalizedValue”:”Relay 600V 10Amp Tesys + Options”,”value”:”Relay 600V 10Amp Tesys + Options”},{“name”:”Standards”,”normalizedValue”:”EN/IEC 60947-5-1, GB/T 14048.5, UL 60947-5-1, CSA C22.2 No 60947-5-1, JIS C8201-5-1″,”value”:”EN/IEC 60947-5-1, GB/T 14048.5, UL 60947-5-1, CSA C22.2 No 60947-5-1, JIS C8201-5-1″},{“name”:”Device Short Name”,”normalizedValue”:”CAD”,”value”:”CAD”},{“name”:”Time Constant”,”normalizedValue”:”28 msec”,”value”:”28 ms”},{“name”:”Range”,”normalizedValue”:”TeSys, Deca”,”value”:”TeSys, TeSys Deca”},{“name”:”Operating Altitude”,”normalizedValue”:”0…9842.52 ft (0…3000 m)”,”value”:”0…9842.52 ft (0…3000 m)”},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA”,”value”:”5 mA”},{“name”:”Maximum Operating Rate”,”normalizedValue”:”180 cyc/mn”,”value”:”180 cyc/mn”},{“name”:”Insulation Resistance”,”normalizedValue”:”\u003e 10 MOhm”,”value”:”\u003e 10 MOhm”},{“name”:”Contactor Application”,”normalizedValue”:”control circuit”,”value”:”control circuit”},{“name”:”Height”,”normalizedValue”:”77 mm”,”value”:”77 mm”},{“name”:”Non-Overlap Time”,”normalizedValue”:”1.5 ms on energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact”,”value”:”1.5 ms on energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact”},{“name”:”Tightening Torque”,”normalizedValue”:”1.2 N.m screw clamp terminals Philips No 2, 1.2 N.m screw clamp terminals flat Ø 6 mm, 1.2 N.m screw clamp terminals pozidriv No 2″,”value”:”1.2 N.m screw clamp terminals Philips No 2, 1.2 N.m screw clamp terminals flat Ø 6 mm, 1.2 N.m screw clamp terminals pozidriv No 2″},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminals 1 1-4 mm²flexible without cable end, screw clamp terminals 2 1-4 mm²flexible without cable end, screw clamp terminals 1 1-4 mm²flexible with cable end, screw clamp terminals 2 1-2.5 mm²flexible with cable end, screw clamp terminals 1 1-4 mm²solid without cable end, screw clamp terminals 2 1-4 mm²solid without cable end”,”value”:”screw clamp terminals 1 1-4 mm²flexible without cable end, screw clamp terminals 2 1-4 mm²flexible without cable end, screw clamp terminals 1 1-4 mm²flexible with cable end, screw clamp terminals 2 1-2.5 mm²flexible with cable end, screw clamp terminals 1 1-4 mm²solid without cable end, screw clamp terminals 2 1-4 mm²solid without cable end”},{“name”:”Depth”,”normalizedValue”:”93 mm”,”value”:”93 mm”},{“name”:”Utilisation Category”,”normalizedValue”:”DC-13, AC-14, AC-15″,”value”:”DC-13, AC-14, AC-15″},{“name”:”Operating Time”,”normalizedValue”:”53…72 ms coil energisation and NO closing, 16…24 ms coil de-energisation and NO opening, 47…63 ms coil energisation and NC opening, 15…25 ms coil de-energisation and NC closing”,”value”:”53…72 ms coil energisation and NO closing, 16…24 ms coil de-energisation and NO opening, 47…63 ms coil energisation and NC opening, 15…25 ms coil de-energisation and NC closing”},{“name”:”Hold-In Power Consumption In W”,”normalizedValue”:”5.4-5.4 W 20°C”,”value”:”5.4-5.4 W 20°C”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”0.1…0.25 Uc -40-70°C drop-out DC, 0.7…1.25 Uc -40-60°C operational DC, 1…1.25 Uc 60-70°C operational DC”,”value”:”0.1…0.25 Uc -40-70°C drop-out DC, 0.7…1.25 Uc -40-60°C operational DC, 1…1.25 Uc 60-70°C operational DC”},{“name”:”Inrush Power In W”,”normalizedValue”:”5.4-5.4 W 20°C)”,”value”:”5.4-5.4 W 20°C)”},{“name”:”[Ith] Conventional Free Air Thermal Current”,”normalizedValue”:”10 A”,”value”:”10 A (at 60°C)”},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG conforming to IEC 60947-5-1″,”value”:”10 A gG conforming to IEC 60947-5-1″},{“name”:”Ip Degree of Protection”,”normalizedValue”:”IP2X front face VDE 0106″,”value”:”IP2X front face VDE 0106″},{“name”:”Mechanical Durability”,”normalizedValue”:”30 Mcycles”,”value”:”30 Mcycles”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-40-60°C, 60-70°C with derating”,”value”:”-40-60°C, 60-70°C with derating”},{“name”:”Product Name”,”normalizedValue”:”TeSys CAD”,”value”:”TeSys CAD”},{“name”:”[Icw] Rated Short-Time Withstand Current”,”normalizedValue”:”100 A to 1 sec, 120 A to 500 msec, 140 A to 100 msec”,”value”:”100 A – 1 s, 120 A – 500 ms, 140 A – 100 ms”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV IEC 60947″,”value”:”6 kV IEC 60947″},{“name”:”Mounting Support”,”normalizedValue”:”plate, rail”,”value”:”plate, rail”},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”48 V DC”,”value”:”48 V DC”},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”\u003c= 690 V AC 25…400 Hz”,”value”:”\u003c= 690 V AC 25…400 Hz”},{“name”:”Mechanical Robustness”,”normalizedValue”:”shocks control relay open10 Gn for 11 ms IEC 60068-2-27, shocks control relay closed15 Gn for 11 ms IEC 60068-2-27, vibrations control relay open2 Gn, 5…300 Hz IEC 60068-2-6, vibrations control relay closed4 Gn, 5…300 Hz IEC 60068-2-6″,”value”:”shocks control relay open10 Gn for 11 ms IEC 60068-2-27, shocks control relay closed15 Gn for 11 ms IEC 60068-2-27, vibrations control relay open2 Gn, 5…300 Hz IEC 60068-2-6, vibrations control relay closed4 Gn, 5…300 Hz IEC 60068-2-6″},{“name”:”Protective Treatment”,”normalizedValue”:”TH IEC 60068″,”value”:”TH IEC 60068″},{“name”:”Width”,”normalizedValue”:”45 mm”,”value”:”45 mm”},{“name”:”Irms Rated Making Capacity”,”normalizedValue”:”140 A AC IEC 60947-5-1, 250 A DC IEC 60947-5-1″,”value”:”140 A AC IEC 60947-5-1, 250 A DC IEC 60947-5-1″},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V”,”value”:”17 V”},{“name”:”Pole Contact Composition”,”normalizedValue”:”3 NO + 2 NC”,”value”:”3 NO + 2 NC”},{“name”:”Control Circuit Type”,”normalizedValue”:”DC standard”,”value”:”DC standard”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-60-80°C”,”value”:”-60-80°C”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”600 V UL, 600 V CSA, 690 V IEC 60947-5-1″,”value”:”600 V UL, 600 V CSA, 690 V IEC 60947-5-1″},{“name”:”Product or Component Type”,”normalizedValue”:”control relay”,”value”:”control relay”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP2X front face VDE 0106″,”value”:”IP2X front face VDE 0106″},{“name”:”Product Or Component Type”,”normalizedValue”:”control relay”,”value”:”control relay”},{“name”:”Conventional Free Air Thermal Current”,”normalizedValue”:”10 A (at 140°F (60°C))”,”value”:”10 A (at 140°F (60°C))”},{“name”:”Product Certifications”,”normalizedValue”:”CB Scheme || CCC || UL || CSA || EAC || CE || UKCA”,”value”:”CB Scheme || CCC || UL || CSA || EAC || CE || UKCA”},{“name”:”Rated Short Time Withstand Current”,”normalizedValue”:”100 A – 1 s; 120 A – 500 ms; 140 A – 100 ms”,”value”:”100 A – 1 s; 120 A – 500 ms; 140 A – 100 ms”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”Less than or Equal to 690 V AC 25 to 400 Hz”,”value”:”Less than or Equal to 690 V AC 25 to 400 Hz”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”600 V UL; 600 V CSA; 690 V IEC 60947-5-1″,”value”:”600 V UL; 600 V CSA; 690 V IEC 60947-5-1″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Indonesia”,”value”:”Indonesia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.