TESYS motor starter kit, LC1D09G7 contac

$124,99

TESYS motor starter kit,LC1D09G7 contac

Out of stock

SKU: GRG4592199 Category:

Description

[{“name”:”Item”,”normalizedValue”:”TESYS motor starter kit,LC1D09G7 contac”,”rank”:1,”value”:”TESYS motor starter kit,LC1D09G7 contac”},{“name”:”Width”,”normalizedValue”:”45 mm”,”value”:”45 mm”},{“name”:”Standards”,”normalizedValue”:”NF C 63-650 || VDE 0113 || IEC 60947-1 || VDE 0660 || CSA C22.2 || IEC 60947-4-1 || NF C 63-120 || NF C 79-130 || IEC 60947-2 || EN 60204 || UL 508, CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508″,”value”:”NF C 63-650 || VDE 0113 || IEC 60947-1 || VDE 0660 || CSA C22.2 || IEC 60947-4-1 || NF C 63-120 || NF C 79-130 || IEC 60947-2 || EN 60204 || UL 508, CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508″},{“name”:”Depth”,”normalizedValue”:”86 mm, 97 mm”,”value”:”86 mm, 97 mm”},{“name”:”Height”,”normalizedValue”:”77 mm, 89 mm”,”value”:”77 mm, 89 mm”},{“name”:”Magnetic Tripping Current”,”normalizedValue”:”13 to 13 A”,”value”:”13-13 A”},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG signalling circuit IEC 60947-5-1 || 25 A gG \u003c= 690 V type 1 power circuit || 20 A gG \u003c= 690 V type 2 power circuit”,”value”:”10 A gG signalling circuit IEC 60947-5-1 || 25 A gG \u003c= 690 V type 1 power circuit || 20 A gG \u003c= 690 V type 2 power circuit”},{“name”:”Permissible Ambient Air Temperature Around The Device”,”normalizedValue”:”-40-70°C at Uc”,”value”:”-40-70°C at Uc”},{“name”:”Power Dissipation Per Pole”,”normalizedValue”:”1.56 W AC-1 || 0.2 W AC-3, 2.5 W”,”value”:”1.56 W AC-1 || 0.2 W AC-3, 2.5 W”},{“name”:”Range”,”normalizedValue”:”TeSys”,”value”:”TeSys”},{“name”:”Mechanical Durability”,”normalizedValue”:”100000 cycles, 15 Mcycles”,”value”:”100000 cycles, 15 Mcycles”},{“name”:”Utilisation Category”,”normalizedValue”:”AC-3 IEC 60947-4-1 ||, AC-3 || AC-1 || AC-4 category, IEC 60947-2″,”value”:”AC-3 || AC-1 || AC-4, AC-3 IEC 60947-4-1 || category A IEC 60947-2″},{“name”:”Mechanical Robustness”,”normalizedValue”:”vibrations contactor open2 Gn, 5…300 Hz || vibrations contactor closed4 Gn, 5…300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms”,”value”:”vibrations contactor open2 Gn, 5…300 Hz || vibrations contactor closed4 Gn, 5…300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms”},{“name”:”Safety Reliability Level”,”normalizedValue”:”B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1″,”value”:”B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1″},{“name”:”Line Rated Current”,”normalizedValue”:”1 A”,”value”:”1A”},{“name”:”Control Type”,”normalizedValue”:”rotary knob”,”value”:”rotary knob”},{“name”:”Overvoltage Category”,”normalizedValue”:”III”,”value”:”III”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-80°C, -60-80 C”,”value”:”-60-80°C, -40-80°C”},{“name”:”Pole Contact Composition”,”normalizedValue”:”3 NO”,”value”:”3 NO”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”drop-out 0.3…0.6 Uc AC 50/60 Hz 60°C) || operational 0.8…1.1 Uc AC 50 Hz 60°C) || operational 0.85…1.1 Uc AC 60 Hz 60°C)”,”value”:”drop-out 0.3…0.6 Uc AC 50/60 Hz 60°C) || operational 0.8…1.1 Uc AC 50 Hz 60°C) || operational 0.85…1.1 Uc AC 60 Hz 60°C)”},{“name”:”Mounting Support”,”normalizedValue”:”rail || plate”,”value”:”rail || plate”},{“name”:”Motor Power Kw”,”normalizedValue”:”2.2 kW 220…230 V AC 50/60 Hz AC-3) || 4 kW 380…400 V AC 50/60 Hz AC-3) || 4 kW 415…440 V AC 50/60 Hz AC-3) || 5.5 kW 500 V AC 50/60 Hz AC-3) || 5.5 kW 660…690 V AC 50/60 Hz AC-3) || 2.2 kW 400 V AC 50/60 Hz AC-4), 0.25-0.25 kW 400/415 V AC 50/60 Hz || 0.55-0.55 kW 690 V AC 50/60 Hz”,”value”:”2.2 kW 220…230 V AC 50/60 Hz AC-3) || 4 kW 380…400 V AC 50/60 Hz AC-3) || 4 kW 415…440 V AC 50/60 Hz AC-3) || 5.5 kW 500 V AC 50/60 Hz AC-3) || 5.5 kW 660…690 V AC 50/60 Hz AC-3) || 2.2 kW 400 V AC 50/60 Hz AC-4), 0.25-0.25 kW 400/415 V AC 50/60 Hz || 0.55-0.55 kW 690 V AC 50/60 Hz”},{“name”:”Phase Failure Sensitivity”,”normalizedValue”:”yes IEC 60947-4-1″,”value”:”yes IEC 60947-4-1″},{“name”:”Insulation Resistance”,”normalizedValue”:”\u003e 10 MOhm signalling circuit”,”value”:”\u003e 10 MOhm signalling circuit”},{“name”:”Maximum Horse Power Rating”,”normalizedValue”:”1 hp 230/240 V at AC 50/60 Hz for 1 phase || 2 hp 200/208 V at AC 50/60 Hz for 3 phase || 2 hp 230/240 V at AC 50/60 Hz for 3 phase || 5 hp 460/480 V at AC 50/60 Hz for 3 phase || 7.5 hp 575/600 V at AC 50/60 Hz for 3 phase || 0.33 hp 115 V at AC 50/60 Hz for 1 phase”,”value”:”1 hp 230/240 V at AC 50/60 Hz for 1 phase || 2 hp 200/208 V at AC 50/60 Hz for 3 phase || 2 hp 230/240 V at AC 50/60 Hz for 3 phase || 5 hp 460/480 V at AC 50/60 Hz for 3 phase || 7.5 hp 575/600 V at AC 50/60 Hz for 3 phase || 0.33 hp 115 V at AC 50/60 Hz for 1 phase”},{“name”:”[Icw] Rated Short-Time Withstand Current”,”normalizedValue”:”105 A 40°C – 10 s power circuit || 210 A 40°C – 1 s power circuit || 30 A 40°C – 10 min power circuit || 61 A 40°C – 1 min power circuit || 100 A – 1 s signalling circuit || 120 A – 500 ms signalling circuit || 140 A – 100 ms signalling circuit”,”value”:”105 A 40°C – 10 s power circuit || 210 A 40°C – 1 s power circuit || 30 A 40°C – 10 min power circuit || 61 A 40°C – 1 min power circuit || 100 A – 1 s signalling circuit || 120 A – 500 ms signalling circuit || 140 A – 100 ms signalling circuit”},{“name”:”Rated Duty”,”normalizedValue”:”continuous IEC 60947-4-1″,”value”:”continuous IEC 60947-4-1″},{“name”:”Trip Unit Technology”,”normalizedValue”:”thermal-magnetic”,”value”:”thermal-magnetic”},{“name”:”Coil Technology”,”normalizedValue”:”without built-in suppressor module”,”value”:”without built-in suppressor module”},{“name”:”Flame Retardance”,”normalizedValue”:”V1 conforming to UL 94″,”value”:”V1 conforming to UL 94″},{“name”:”Signalling Circuit Frequency”,”normalizedValue”:”25…400 Hz”,”value”:”25…400 Hz”},{“name”:”Motor Starter Type”,”normalizedValue”:”direct on-line contactor”,”value”:”direct on-line contactor”},{“name”:”Power Range”,”normalizedValue”:”0-0.5 kW 100-120 V 3 phase || 0.55-1 kW 100-120 V 3 phase || 0-0.5 kW 200-240 V 3 phase || 0.55-1 kW 200-240 V 3 phase || 1.1-2 kW 200-240 V 3 phase || 0-0.5 kW 380-440 V 3 phase || 0.55-1 kW 380-440 V 3 phase || 1.1-2 kW 380-440 V 3 phase || 2.2-3 kW 380-440 V 3 phase || 4-6 kW 380-440 V 3 phase || 0-0.5 kW 480-500 V 3 phase || 0.55-1 kW 480-500 V 3 phase || 1.1-2 kW 480-500 V 3 phase || 2.2-3 kW 480-500 V 3 phase || 4-6 kW 480-500 V 3 phase || 0-0.5 kW 525-690 V 3 phase || 0.55-1 kW 525-690 V 3 phase || 1.1-2 kW 525-690 V 3 phase || 2.2-3 kW 525-690 V 3 phase || 4-6 kW 525-690 V 3 phase”,”value”:”0-0.5 kW 100-120 V 3 phase || 0.55-1 kW 100-120 V 3 phase || 0-0.5 kW 200-240 V 3 phase || 0.55-1 kW 200-240 V 3 phase || 1.1-2 kW 200-240 V 3 phase || 0-0.5 kW 380-440 V 3 phase || 0.55-1 kW 380-440 V 3 phase || 1.1-2 kW 380-440 V 3 phase || 2.2-3 kW 380-440 V 3 phase || 4-6 kW 380-440 V 3 phase || 0-0.5 kW 480-500 V 3 phase || 0.55-1 kW 480-500 V 3 phase || 1.1-2 kW 480-500 V 3 phase || 2.2-3 kW 480-500 V 3 phase || 4-6 kW 480-500 V 3 phase || 0-0.5 kW 525-690 V 3 phase || 0.55-1 kW 525-690 V 3 phase || 1.1-2 kW 525-690 V 3 phase || 2.2-3 kW 525-690 V 3 phase || 4-6 kW 525-690 V 3 phase”},{“name”:”Fire Resistance”,”normalizedValue”:”850°C IEC 60695-2-1″,”value”:”850°C IEC 60695-2-1″},{“name”:”[Ics] Rated Service Short-Circuit Breaking Capacity”,”normalizedValue”:”100 % 690 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2″,”value”:”100 % 690 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2″},{“name”:”Protective Cover”,”normalizedValue”:”With”,”value”:”with”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL, 690 V AC 50/60 Hz IEC 60947-2″,”value”:”power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL, 690 V AC 50/60 Hz IEC 60947-2″},{“name”:”Product Certifications”,”normalizedValue”:”TSE || LROS (Lloyds register of shipping) || DNV || UL 508 type E || CSA || RINA || EZU || UL || ATEX || GL || CCC || BV || EAC, RINA || DNV || GOST || LROS (Lloyds register of shipping) || UL || GL || BV || CCC || CSA”,”value”:”TSE || LROS (Lloyds register of shipping) || DNV || UL 508 type E || CSA || RINA || EZU || UL || ATEX || GL || CCC || BV || EAC, RINA || DNV || GOST || LROS (Lloyds register of shipping) || UL || GL || BV || CCC || CSA”},{“name”:”Poles Description”,”normalizedValue”:”3P”,”value”:”3P”},{“name”:”Irms Rated Making Capacity”,”normalizedValue”:”250 A 440 V power circuit IEC 60947 || 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1″,”value”:”250 A 440 V power circuit IEC 60947 || 140 A AC signalling circuit IEC 60947-5-1 || 250 A DC signalling circuit IEC 60947-5-1″},{“name”:”Protective Treatment”,”normalizedValue”:”TH”,”value”:”TH”},{“name”:”Network Frequency”,”normalizedValue”:”50/60 Hz IEC 60947-4-1″,”value”:”50/60 Hz IEC 60947-4-1″},{“name”:”Operating Time”,”normalizedValue”:”12…22 ms closing || 4…19 ms opening”,”value”:”12…22 ms closing || 4…19 ms opening”},{“name”:”Fixing Mode”,”normalizedValue”:”35 mm symmetrical DIN rail clipped || panel screwed with 2 x M4 screws)”,”value”:”35 mm symmetrical DIN rail clipped || panel screwed with 2 x M4 screws)”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV IEC 60947, 6 kV IEC 60947-2″,”value”:”6 kV IEC 60947, 6 kV IEC 60947-2″},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”120 V AC 50/60 Hz”,”value”:”120 V AC 50/60 Hz”},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”power circuit \u003c= 690 V AC 25…400 Hz || power circuit \u003c= 300 V DC, 690 V AC 50/60 Hz IEC 60947-2″,”value”:”power circuit \u003c= 690 V AC 25…400 Hz || power circuit \u003c= 300 V DC, 690 V AC 50/60 Hz IEC 60947-2″},{“name”:”Rated Breaking Capacity”,”normalizedValue”:”250 A 440 V power circuit IEC 60947″,”value”:”250 A 440 V power circuit IEC 60947″},{“name”:”Operating Position”,”normalizedValue”:”any position”,”value”:”any position”},{“name”:”Electrical Durability”,”normalizedValue”:”0.6 Mcycles 25 A AC-1 \u003c= 440 V || 2 Mcycles 9 A AC-3 \u003c= 440 V, 100000 cycles AC-3 440 V”,”value”:”0.6 Mcycles 25 A AC-1 \u003c= 440 V || 2 Mcycles 9 A AC-3 \u003c= 440 V, 100000 cycles AC-3 440 V”},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA signalling circuit”,”value”:”5 mA signalling circuit”},{“name”:”[Ie] Rated Operational Current”,”normalizedValue”:”9 A 60°C) \u003c= 440 V AC AC-3 power circuit || 25 A 60°C) \u003c= 440 V AC AC-1 power circuit”,”value”:”9 A 60°C) \u003c= 440 V AC AC-3 power circuit || 25 A 60°C) \u003c= 440 V AC AC-1 power circuit”},{“name”:”Auxiliary Contact Composition”,”normalizedValue”:”1 NO + 1 NC”,”value”:”1 NO + 1 NC”},{“name”:”Climatic Withstand”,”normalizedValue”:”IACS E10″,”value”:”IACS E10″},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V signalling circuit”,”value”:”17 V signalling circuit”},{“name”:”Hold-In Power Consumption In Va”,”normalizedValue”:”7.5-7.5 VA 60 Hz 0.3 20°C) || 7-7 VA 50 Hz 0.3 20°C)”,”value”:”7.5-7.5 VA 60 Hz 0.3 20°C) || 7-7 VA 50 Hz 0.3 20°C)”},{“name”:”Maximum Operating Rate”,”normalizedValue”:”25 cyc/h, 3600 cyc/h 60°C”,”value”:”25 cyc/h, 3600 cyc/h 60°C”},{“name”:”Suitability For Isolation”,”normalizedValue”:”yes IEC 60947-1″,”value”:”yes IEC 60947-1″},{“name”:”Product Or Component Type”,”normalizedValue”:”motor starter”,”value”:”motor starter”},{“name”:”Control Circuit Type”,”normalizedValue”:”AC 50/60 Hz”,”value”:”AC 50/60 Hz”},{“name”:”Non-Overlap Time”,”normalizedValue”:”1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact”,”value”:”1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact”},{“name”:”Tightening Torque”,”normalizedValue”:”1.7 N.m screw clamp terminals, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2″,”value”:”1.7 N.m screw clamp terminals, power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2″},{“name”:”Contact Compatibility”,”normalizedValue”:”M2″,”value”:”M2″},{“name”:”Inrush Power In Va”,”normalizedValue”:”70-70 VA 60 Hz 0.75 20°C) || 70-70 VA 50 Hz 0.75 20°C)”,”value”:”70-70 VA 60 Hz 0.75 20°C) || 70-70 VA 50 Hz 0.75 20°C)”},{“name”:”Breaking Capacity”,”normalizedValue”:”100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2″,”value”:”100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2″},{“name”:”[Ith] Conventional Free Air Thermal Current”,”normalizedValue”:”1 A IEC 60947-4-1, 25 A 60°C power circuit || 10 A 60°C signalling circuit”,”value”:”1 A IEC 60947-4-1, 25 A 60°C power circuit || 10 A 60°C signalling circuit”},{“name”:”Heat Dissipation”,”normalizedValue”:”2-3 W 50/60 Hz”,”value”:”2-3 W 50/60 Hz”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-60°C, -5-60°C”,”value”:”-20-60°C, -5-60°C”},{“name”:”Auxiliary Contacts Type”,”normalizedValue”:”mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1″,”value”:”mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1″},{“name”:”Trip Unit Rating”,”normalizedValue”:”0.63 to 1 A”,”value”:”0.63-1 A”},{“name”:”Average Impedance”,”normalizedValue”:”2.5 mOhm – Ith 25 A 50 Hz power circuit”,”value”:”2.5 mOhm – Ith 25 A 50 Hz power circuit”},{“name”:”Pollution Degree”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Ik Degree Of Protection”,”normalizedValue”:”IK04″,”value”:”IK04″},{“name”:”Contactor Application”,”normalizedValue”:”resistive load || motor control”,”value”:”resistive load || motor control”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminals 2 1-6 mm² solid || screw clamp terminals 2 1.5-6 mm² flexible without cable end || screw clamp terminals 2 1-4 mm² flexible with cable end, power circuit screw clamp terminals 1 1-4 mm²flexible without cable end || power circuit screw clamp terminals 2 1-4 mm²flexible without cable end || power circuit screw clamp terminals 1 1-4 mm²flexible with cable end || power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || power circuit screw clamp terminals 1 1-4 mm²solid without cable end || power circuit screw clamp terminals 2 1-4 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end”,”value”:”screw clamp terminals 2 1-6 mm² solid || screw clamp terminals 2 1.5-6 mm² flexible without cable end || screw clamp terminals 2 1-4 mm² flexible with cable end, power circuit screw clamp terminals 1 1-4 mm²flexible without cable end || power circuit screw clamp terminals 2 1-4 mm²flexible without cable end || power circuit screw clamp terminals 1 1-4 mm²flexible with cable end || power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || power circuit screw clamp terminals 1 1-4 mm²solid without cable end || power circuit screw clamp terminals 2 1-4 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end”},{“name”:”Operating Altitude”,”normalizedValue”:”9842.52 ft (3000 m) without derating, 6561.68 ft (2000 m)”,”value”:”9842.52 ft (3000 m) without derating, 6561.68 ft (2000 m)”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 IEC 60529, IP20 front face IEC 60529″,”value”:”IP20 IEC 60529, IP20 front face IEC 60529″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Thailand”,”value”:”Thailand”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “TESYS motor starter kit, LC1D09G7 contac”