Description
[{“name”:”Item”,”normalizedValue”:”TeSys Vario – emergency stop switch disc”,”rank”:1,”value”:”TeSys Vario – emergency stop switch disc”},{“name”:”Standards”,”normalizedValue”:”IEC 60947-3″,”rank”:8,”value”:”IEC 60947-3″},{“name”:”Width”,”normalizedValue”:”60 mm”,”value”:”60 mm”},{“name”:”Height”,”normalizedValue”:”74 mm”,”value”:”74 mm”},{“name”:”Rated Conditional Short-Circuit Current”,”normalizedValue”:”10 kA 400 V 20 A aM || 10 kA 400 V 20 A gG”,”value”:”10 kA 400 V 20 A aM || 10 kA 400 V 20 A gG”},{“name”:”Poles Description”,”normalizedValue”:”3 P”,”value”:”3P”},{“name”:”Network Type”,”normalizedValue”:”DC || AC”,”value”:”DC || AC”},{“name”:”Product Name”,”normalizedValue”:”TeSys VARIO”,”value”:”TeSys VARIO”},{“name”:”Device Short Name”,”normalizedValue”:”VCD”,”value”:”VCD”},{“name”:”Making Capacity”,”normalizedValue”:”200 A 400 V AC-21A || 200 A 400 V AC-22A || 200 A 400 V AC-23A”,”value”:”200 A 400 V AC-21A || 200 A 400 V AC-22A || 200 A 400 V AC-23A”},{“name”:”[Icm] Rated Short-Circuit Making Capacity”,”normalizedValue”:”1 kA 400 V at Ipeak”,”value”:”1 kA 400 V at Ipeak”},{“name”:”Rotary Handle Padlocking”,”normalizedValue”:”1 to 3 padlocks 4-8 mm”,”value”:”1 to 3 padlocks 4-8 mm”},{“name”:”Rated Operational Power In W”,”normalizedValue”:”11 kW 690 V AC-23A) || 3 kW 230…240 V AC-3) || 4 kW 400…415 V AC-3) || 5.5 kW 500 V AC-3) || 7.5 kW 500 V AC-23A) || 7.5 kW 690 V AC-3) || 4 kW 230…240 V AC-23A) || 5.5 kW 400…415 V AC-23A)”,”value”:”11 kW 690 V AC-23A) || 3 kW 230…240 V AC-3) || 4 kW 400…415 V AC-3) || 5.5 kW 500 V AC-3) || 7.5 kW 500 V AC-23A) || 7.5 kW 690 V AC-3) || 4 kW 230…240 V AC-23A) || 5.5 kW 400…415 V AC-23A)”},{“name”:”[Icw] Rated Short-Time Withstand Current”,”normalizedValue”:”300 A 400 V 1 s”,”value”:”300 A 400 V 1 s”},{“name”:”Device Composition”,”normalizedValue”:”switch || handle”,”value”:”switch || handle”},{“name”:”Fixing Mode”,”normalizedValue”:”hole 22.5 mm handle”,”value”:”hole 22.5 mm handle”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 conforming to IEC 60529 || IP65″,”value”:”IP20 conforming to IEC 60529 || IP65″},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”690 V AC 50/60 Hz”,”value”:”690 V AC 50/60 Hz”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”3 NO”,”value”:”3 NO”},{“name”:”Control Type”,”normalizedValue”:”rotary handle”,”value”:”rotary handle”},{“name”:”Performance Level”,”normalizedValue”:”high performance”,”value”:”high performance”},{“name”:”[Ie] Rated Operational Current”,”normalizedValue”:”11 A AC-23 Ue: 400 V”,”value”:”11 A AC-23 Ue: 400 V”},{“name”:”Handle Front Plate Colour”,”normalizedValue”:”yellow”,”value”:”yellow”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV”,”value”:”8 kV”},{“name”:”Base Dimension”,”normalizedValue”:”60 x 60 mm”,”value”:”60 x 60 mm”},{“name”:”Rotary Handle Mounting Style”,”normalizedValue”:”direct”,”value”:”direct”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-50°C”,”value”:”-20-50°C”},{“name”:”Product Certifications”,”normalizedValue”:”GL || UL || CSA || CCC || UKCA”,”value”:”GL || UL || CSA || CCC || UKCA”},{“name”:”Mounting Support”,”normalizedValue”:”handle door || switch door”,”value”:”handle door || switch door”},{“name”:”Product Or Component Type”,”normalizedValue”:”emergency stop switch disconnector”,”value”:”emergency stop switch disconnector”},{“name”:”Protective Treatment”,”normalizedValue”:”TC”,”value”:”TC”},{“name”:”Tightening Torque”,”normalizedValue”:”power circuit 2.1-2.1 N.m screw clamp terminals”,”value”:”power circuit 2.1-2.1 N.m screw clamp terminals”},{“name”:”Mechanical Robustness”,”normalizedValue”:”vibrations 10…150 Hz 1 gn) IEC 60068-2-6 || shocks 11 ms 30 Gn) IEC 60068-2-27″,”value”:”vibrations 10…150 Hz 1 gn) IEC 60068-2-6 || shocks 11 ms 30 Gn) IEC 60068-2-27″},{“name”:”Connections – Terminals”,”normalizedValue”:”power circuit screw clamp terminals 10-10 mm² solid || power circuit screw clamp terminals 6-6 mm² flexible – with cable end”,”value”:”power circuit screw clamp terminals 10-10 mm² solid || power circuit screw clamp terminals 6-6 mm² flexible – with cable end”},{“name”:”[Ithe] Conventional Enclosed Thermal Current”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Range”,”normalizedValue”:”TeSys”,”value”:”TeSys”},{“name”:”[Ith] Conventional Free Air Thermal Current”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Breaking Capacity”,”normalizedValue”:”200 A 400 V AC-21A) || 200 A 400 V AC-22A) || 200 A 400 V AC-23A)”,”value”:”200 A 400 V AC-21A) || 200 A 400 V AC-22A) || 200 A 400 V AC-23A)”},{“name”:”Compatibility Code”,”normalizedValue”:”main switch disconnector”,”value”:”main switch disconnector”},{“name”:”Handle Colour”,”normalizedValue”:”red”,”value”:”red”},{“name”:”Suitability For Isolation”,”normalizedValue”:”yes”,”value”:”yes”},{“name”:”Fire Resistance”,”normalizedValue”:”960°C IEC 60695-2-1″,”value”:”960°C IEC 60695-2-1″},{“name”:”Intermittent Duty Class”,”normalizedValue”:”30″,”value”:”30″},{“name”:”Marking”,”normalizedValue”:”0 – 1″,”value”:”0 – 1″},{“name”:”Mechanical Durability”,”normalizedValue”:”100,000 cycle”,”value”:”100000 cycles”},{“name”:”Electrical Durability”,”normalizedValue”:”100000 cycles AC-21 || 30000 cycles DC-1…5″,”value”:”100000 cycles AC-21 || 30000 cycles DC-1…5″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.