Description
[{“name”:”Item”,”normalizedValue”:”Switch Kit”,”rank”:1,”value”:”Switch Kit”},{“name”:”Standards”,”normalizedValue”:”IEC 60947-3″,”value”:”IEC 60947-3″},{“name”:”Height”,”normalizedValue”:”125 mm”,”value”:”125 mm”},{“name”:”Mechanical Durability”,”normalizedValue”:”30,000 cycle”,”value”:”30000 cycles”},{“name”:”Rotary Handle Padlocking”,”normalizedValue”:”1 to 3 padlocks 4-8 mm”,”value”:”1 to 3 padlocks 4-8 mm”},{“name”:”Handle Colour”,”normalizedValue”:”red”,”value”:”red”},{“name”:”Breaking Capacity”,”normalizedValue”:”1000 A 400 V AC-21A) || 1000 A 400 V AC-22A) || 1000 A 400 V AC-23A)”,”value”:”1000 A 400 V AC-21A) || 1000 A 400 V AC-22A) || 1000 A 400 V AC-23A)”},{“name”:”Fire Resistance”,”normalizedValue”:”960°C IEC 60695-2-1″,”value”:”960°C IEC 60695-2-1″},{“name”:”Contacts Type And Composition”,”normalizedValue”:”3 NO”,”value”:”3 NO”},{“name”:”Width”,”normalizedValue”:”90 mm”,”value”:”90 mm”},{“name”:”Connections – Terminals”,”normalizedValue”:”power circuit screw clamp terminals 95-95 mm² solid || power circuit screw clamp terminals 70-70 mm² flexible – with cable end”,”value”:”power circuit screw clamp terminals 95-95 mm² solid || power circuit screw clamp terminals 70-70 mm² flexible – with cable end”},{“name”:”Making Capacity”,”normalizedValue”:”1250 A 400 V AC-21A || 1250 A 400 V AC-22A || 1250 A 400 V AC-23A”,”value”:”1250 A 400 V AC-21A || 1250 A 400 V AC-22A || 1250 A 400 V AC-23A”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-50°C”,”value”:”-20-50°C”},{“name”:”Rotary Handle Mounting Style”,”normalizedValue”:”extended”,”value”:”extended”},{“name”:”Electrical Durability”,”normalizedValue”:”30000 cycles AC-21 || 30000 cycles DC-1 to 5″,”value”:”30000 cycles AC-21 || 30000 cycles DC-1 to 5″},{“name”:”Handle Front Plate Colour”,”normalizedValue”:”yellow”,”value”:”yellow”},{“name”:”Base Dimension”,”normalizedValue”:”90 mm x 90 mm”,”value”:”90 x 90 mm”},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”690 V AC 50/60 Hz”,”value”:”690 V AC 50/60 Hz”},{“name”:”Fixing Mode”,”normalizedValue”:”by 4 screws handle || by clips switch || by screws switch”,”value”:”by 4 screws handle || by clips switch || by screws switch”},{“name”:”Product Name”,”normalizedValue”:”TeSys VARIO”,”value”:”TeSys VARIO”},{“name”:”[Ith] Conventional Free Air Thermal Current”,”normalizedValue”:”125 A”,”value”:”125 A”},{“name”:”Poles Description”,”normalizedValue”:”3P”,”value”:”3P”},{“name”:”Performance Level”,”normalizedValue”:”high performance”,”value”:”high performance”},{“name”:”Mechanical Robustness”,”normalizedValue”:”vibrations 10 to 150 Hz 1 gn) IEC 60068-2-6 || shocks 11 ms 30 Gn) IEC 60068-2-27″,”value”:”vibrations 10 to 150 Hz 1 gn) IEC 60068-2-6 || shocks 11 ms 30 Gn) IEC 60068-2-27″},{“name”:”Control Type”,”normalizedValue”:”rotary handle”,”value”:”rotary handle”},{“name”:”Tightening Torque”,”normalizedValue”:”clamp terminals”,”value”:”power circuit 22.6-22.6 N.m screw clamp terminals”},{“name”:”Compatibility Code”,”normalizedValue”:”main switch disconnector”,”value”:”main switch disconnector”},{“name”:”Rated Operational Power In W”,”normalizedValue”:”22 kW 230 to 240 V AC-3) || 30 kW 400 to 415 V AC-3) || 30 kW 690 V AC-3) || 37 kW 500 V AC-3) || 37 kW 690 V AC-23A) || 45 kW 500 V AC-23A) || 22 kW 230 to 240 V AC-23A) || 37 kW 400 to 415 V AC-23A)”,”value”:”22 kW 230 to 240 V AC-3) || 30 kW 400 to 415 V AC-3) || 30 kW 690 V AC-3) || 37 kW 500 V AC-3) || 37 kW 690 V AC-23A) || 45 kW 500 V AC-23A) || 22 kW 230 to 240 V AC-23A) || 37 kW 400 to 415 V AC-23A)”},{“name”:”Mounting Support”,”normalizedValue”:”handle door || switch symmetrical rail || switch plate”,”value”:”handle door || switch symmetrical rail || switch plate”},{“name”:”Device Short Name”,”normalizedValue”:”VCCF”,”value”:”VCCF”},{“name”:”[Ie] Rated Operational Current”,”normalizedValue”:”68.5 A AC-23 Ue: 400 V”,”value”:”68.5 A AC-23 Ue: 400 V”},{“name”:”Intermittent Duty Class”,”normalizedValue”:”30″,”value”:”30″},{“name”:”Range”,”normalizedValue”:”TeSys”,”value”:”TeSys”},{“name”:”[Ithe] Conventional Enclosed Thermal Current”,”normalizedValue”:”100 A”,”value”:”100 A”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 conforming to IEC 60529 || IP65″,”value”:”IP20 conforming to IEC 60529 || IP65″},{“name”:”Network Type”,”normalizedValue”:”DC || AC”,”value”:”DC || AC”},{“name”:”Rated Conditional Short-Circuit Current”,”normalizedValue”:”10 kA 400 V 125 A aM || 10 kA 400 V 125 A gG”,”value”:”10 kA 400 V 125 A aM || 10 kA 400 V 125 A gG”},{“name”:”[Icm] Rated Short-Circuit Making Capacity”,”normalizedValue”:”2.8 kA 400 V at Ipeak”,”value”:”2.8 kA 400 V at Ipeak”},{“name”:”Product Certifications”,”normalizedValue”:”CCC || UL || CSA || GL || UKCA”,”value”:”CCC || UL || CSA || GL || UKCA”},{“name”:”[Icw] Rated Short-Time Withstand Current”,”normalizedValue”:”1500 A 400 V 1 s”,”value”:”1500 A 400 V 1 s”},{“name”:”Protective Treatment”,”normalizedValue”:”TC”,”value”:”TC”},{“name”:”Product Or Component Type”,”normalizedValue”:”emergency stop switch disconnector”,”value”:”emergency stop switch disconnector”},{“name”:”Suitability For Isolation”,”normalizedValue”:”yes”,”value”:”yes”},{“name”:”Device Composition”,”normalizedValue”:”handle || switch || shaft extension”,”value”:”handle || switch || shaft extension”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV”,”value”:”8 kV”},{“name”:”Marking”,”normalizedValue”:”0 – 1″,”value”:”0 – 1″},{“name”:”Degree Of Protection”,”normalizedValue”:”IP20 conforming to IEC 60529; IP65″,”value”:”IP20 conforming to IEC 60529; IP65″},{“name”:”Mounting Method”,”normalizedValue”:”By 4 screws handle; By clips switch; By screws switch”,”value”:”By 4 screws handle; By clips switch; By screws switch”},{“name”:”IEC Terminal Connection”,”normalizedValue”:”Power circuit screw clamp terminals 0.15 in² (95 mm²) solid; Power circuit screw clamp terminals 0.11 in² (70 mm²) flexible – with cable end”,”value”:”Power circuit screw clamp terminals 0.15 in² (95 mm²) solid; Power circuit screw clamp terminals 0.11 in² (70 mm²) flexible – with cable end”},{“name”:”Rated Conditional Short Circuit Current”,”normalizedValue”:”10 kA 400 V 125 A aM; 10 kA 400 V 125 A gG”,”value”:”10 kA 400 V 125 A aM; 10 kA 400 V 125 A gG”},{“name”:”Iec Rated Operational Power in W”,”normalizedValue”:”22 kW 230 to 240 V AC-3); 30 kW 400 to 415 V AC-3); 30 kW 690 V AC-3); 37 kW 500 V AC-3); 37 kW 690 V AC-23A); 45 kW 500 V AC-23A); 22 kW 230 to 240 V AC-23A); 37 kW 400 to 415 V AC-23A)”,”value”:”22 kW 230 to 240 V AC-3); 30 kW 400 to 415 V AC-3); 30 kW 690 V AC-3); 37 kW 500 V AC-3); 37 kW 690 V AC-23A); 45 kW 500 V AC-23A); 22 kW 230 to 240 V AC-23A); 37 kW 400 to 415 V AC-23A)”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Czechia”,”value”:”Czechia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.