Straight Blade Receptacle, 5-20R, 20 A, 125V AC, 2 Pole, 3 Wire, Flush Mount, Single

$32,95

Receptacle, Connection Orientation Straight, Cover Type No Cover, Current Rating 20 A, GFCI No, Grounding Grounded, Housing Color Light Almond, Housing Material Thermoplastic, Mount Type Flush, NEMA Enclosure Rating 1, NEMA Receptacle Configuration 5-20R, Number of Gangs 1, Number of Poles 2, Number of Wires 3, Phase Single, Polarized Yes, Resistance Properties Impact Resistant, Standards CSA Certified C22.2 No. 42 File 285, Federal Specification W-C-596, NEMA WD-6, UL 498 File E2186

9999 in stock

SKU: GRG4440366 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Straight Blade Receptacle”,”rank”:1,”value”:”Straight Blade Receptacle”},{“name”:”Receptacle Type”,”normalizedValue”:”Duplex”,”rank”:2,”value”:”Duplex”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-20R”,”rank”:3,”value”:”5-20R”},{“name”:”Current Rating”,”normalizedValue”:”20 A”,”rank”:4,”value”:”20 A”},{“name”:”Voltage Rating”,”normalizedValue”:”125V AC”,”rank”:5,”value”:”125V AC”},{“name”:”Phase”,”normalizedValue”:”Single”,”rank”:6,”value”:”Single”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:7,”value”:”2″},{“name”:”Number of Wires”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Wire Connection Type”,”normalizedValue”:”Screw Terminals”,”rank”:9,”value”:”Screw Terminals”},{“name”:”Wiring Method”,”normalizedValue”:”Side, Back”,”rank”:10,”value”:”Back, Side”},{“name”:”Grounding”,”normalizedValue”:”Grounded”,”rank”:11,”value”:”Grounded”},{“name”:”Housing Color”,”normalizedValue”:”Light Almond”,”rank”:12,”value”:”Light Almond”},{“name”:”Mount Type”,”normalizedValue”:”Flush”,”rank”:13,”value”:”Flush”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”rank”:14,”value”:”IP20″},{“name”:”Standards”,”normalizedValue”:”CSA Certified, NEMA WD-6, UL Listed”,”rank”:15,”value”:”CSA Certified, NEMA WD-6, UL Listed”},{“name”:”Resistance Properties”,”normalizedValue”:”Impact Resistant”,”rank”:16,”value”:”Impact Resistant”},{“name”:”Flange Type”,”normalizedValue”:”Non-Flanged”,”rank”:17,”value”:”Non-Flanged”},{“name”:”Tamper Resistant”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Sub-Category”,”normalizedValue”:”Duplex Receptacles”,”value”:”Duplex Receptacles”},{“name”:”Surge Suppression”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Color – Plugs and Receptacles”,”normalizedValue”:”Light Almond”,”value”:”Light Almond”},{“name”:”Outlet Type”,”normalizedValue”:”Duplex”,”value”:”Duplex”},{“name”:”HP”,”normalizedValue”:”1 hp”,”value”:”1 hp”},{“name”:”Mounting Type – Plugs and Receptacles”,”normalizedValue”:”Flush”,”value”:”Flush”},{“name”:”Weather Resistant – Plugs and Receptacles”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Description”,”normalizedValue”:”Finder Groove”,”value”:”Finder Groove”},{“name”:”Mounting Type”,”normalizedValue”:”Flush”,”value”:”Flush”},{“name”:”Material”,”normalizedValue”:”Nylon”,”value”:”Nylon”},{“name”:”Outlet Type – Plugs and Receptacles”,”normalizedValue”:”Standard Duplex”,”value”:”Standard Duplex”},{“name”:”Amps”,”normalizedValue”:”20″,”value”:”20″},{“name”:”NEMA Rating”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Application Environment”,”normalizedValue”:”Heavy Use Hospital Grade”,”value”:”Heavy Use Hospital Grade”},{“name”:”Number of Gangs”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Weather Resistant”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Wiring Method – Plugs and Receptacles”,”normalizedValue”:”Side, Back”,”value”:”Back and Side”},{“name”:”Height”,”normalizedValue”:”1.05 in”,”value”:”1.05 in”},{“name”:”Width”,”normalizedValue”:”1.33 in”,”value”:”1.33 in”},{“name”:”Surge Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Horsepower Rating”,”normalizedValue”:”1 HP”,”value”:”1 hp”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Cover Type”,”normalizedValue”:”No Cover”,”value”:”No Cover”},{“name”:”Mount Hole Center-to-Center Height”,”normalizedValue”:”3.3 in”,”value”:”3.3 in”},{“name”:”UL 94 Flammability Rating”,”normalizedValue”:”V-0″,”value”:”V-0″},{“name”:”Face Plate Height”,”normalizedValue”:”2.7 in”,”value”:”2.7 in”},{“name”:”Market”,”normalizedValue”:”Commercial”,”value”:”Commercial”},{“name”:”Includes”,”normalizedValue”:”Grounding Staple, Mounting Hardware, Wall Plate or Weatherproof Cover”,”value”:”Grounding Staple, Mounting Hardware, Wall Plate or Weatherproof Cover”},{“name”:”Housing Material”,”normalizedValue”:”Thermoplastic”,”value”:”Thermoplastic”},{“name”:”Face Plate Width”,”normalizedValue”:”1.3 in”,”value”:”1.3 in”},{“name”:”Maximum Wire Size”,”normalizedValue”:”10 AWG”,”value”:”10 AWG”},{“name”:”GFCI”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Contact Material”,”normalizedValue”:”Brass”,”value”:”Brass”},{“name”:”Overall Depth”,”normalizedValue”:”1.1 in”,”value”:”1.1 in”},{“name”:”For Location”,”normalizedValue”:”Indoor”,”value”:”Indoor”},{“name”:”Minimum Wire Size”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Connection Orientation”,”normalizedValue”:”Straight”,”value”:”Straight”},{“name”:”Shrouded”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Polarized”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”167 deg F”,”value”:”167 Degrees F”},{“name”:”Grade”,”normalizedValue”:”Hospital Grade Fed. Spec.”,”value”:”Hospital Grade Fed. Spec.”},{“name”:”Includes Mounting Hardware”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AFCI”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Face Style”,”normalizedValue”:”Finder Groove”,”value”:”Finder Groove”},{“name”:”Standard”,”normalizedValue”:”NEMA”,”value”:”NEMA”},{“name”:”Horsepower”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Top Material”,”normalizedValue”:”Impact Modified PBT”,”value”:”Impact Modified PBT”},{“name”:”Operating Temperatures”,”normalizedValue”:”Maximum continuous 75°C, minimum -40°C”,”value”:”Maximum continuous 75°C; minimum -40°C (w/o impact)”},{“name”:”Current Interrupting”,”normalizedValue”:”Certified for current interrupting at full rated current”,”value”:”Certified for current interrupting at full rated current”},{“name”:”Poles and Wires”,”normalizedValue”:”2 Pole, 3-Wire Grounding”,”value”:”2 Pole, 3-Wire Grounding”},{“name”:”Ground Screw Material”,”normalizedValue”:”#10-32 Silicon Bronze”,”value”:”#10-32 Silicon Bronze (Green)”},{“name”:”Mounting Screw Material”,”normalizedValue”:”Stainless Steel”,”value”:”Stainless Steel”},{“name”:”Rating”,”normalizedValue”:”20A, 125V”,”value”:”20A, 125V”},{“name”:”Face Shape”,”normalizedValue”:”Traditional”,”value”:”Traditional”},{“name”:”Flammability”,”normalizedValue”:”UL 94 V-0, UL 94 V0 and UL 94-5 VA.”,”value”:”UL 94 V-0, UL 94 V0 and UL 94-5 VA.”},{“name”:”Power Contacts Material”,”normalizedValue”:”Brass, Ni Plated”,”value”:”.037\” (.9) Brass – Ni Plated”},{“name”:”Terminal Screw Material”,”normalizedValue”:”#10-32 Silicon Bronze”,”value”:”#10-32 Silicon Bronze (Ni plate if neutral)”},{“name”:”Other Available Colors”,”normalizedValue”:”Brown, Ivory, Gray, Red, White, Light Almond”,”value”:”Brown, Ivory, Gray, Red, White, Light Almond”},{“name”:”Terminal Identification”,”normalizedValue”:”Terminals identified in accordance with UL 498 and CSA”,”value”:”Terminals identified in accordance with UL 498 and CSA”},{“name”:”Auto Ground Clip Material”,”normalizedValue”:”Stainless Steel”,”value”:”Stainless Steel”},{“name”:”Device Color”,”normalizedValue”:”Light Almond”,”value”:”Light Almond”},{“name”:”Temperature Rise”,”normalizedValue”:”Max 30°C temperature rise at full rated current after 50 cycles of overload at 150% of rated current at a power factor of 75%..”,”value”:”Max 30°C temperature rise at full rated current after 50 cycles of overload at 150% of rated current at a power factor of 75%..”},{“name”:”Receptacle Style”,”normalizedValue”:”Duplex”,”value”:”Duplex”},{“name”:”Terminal Accommodation”,”normalizedValue”:”solid copper wire only, #12-#10 AWG stranded”,”value”:”#12-#10 AWG stranded or solid copper wire only”},{“name”:”Receptacle Grade”,”normalizedValue”:”Compact Hospital Grade”,”value”:”Compact Hospital Grade”},{“name”:”Dielectric Voltage”,”normalizedValue”:”Withstands 2,000V minimum”,”value”:”Withstands 2,000V minimum”},{“name”:”Certification”,”normalizedValue”:”UL Listed, File E2186, Guide RTRT Fed Spec WC596G, Hospital Grade Meets NEMA WD-1 Heavy Duty and WD-6 requirements Listed to UL Standard 498, Certified to CSA, C22.2, No. 42 where applicable”,”value”:”UL Listed, File E2186, Guide RTRT Fed Spec WC596G, Hospital Grade Meets NEMA WD-1 Heavy Duty and WD-6 requirements Listed to UL Standard 498, Certified to CSA, C22.2, No. 42 where applicable”},{“name”:”Base Material”,”normalizedValue”:”Reinforced PET”,”value”:”Reinforced PET”},{“name”:”Mounting Strap Material”,”normalizedValue”:”.050\” Brass”,”value”:”.050\” (1.3) Brass-Ni Plated”},{“name”:”OEM Brand Name”,”normalizedValue”:”Hubbell Wiring Device-Kellems”,”value”:”Hubbell Wiring Device-Kellems”},{“name”:”Application”,”normalizedValue”:”Slender/Compact Hospital Grade”,”value”:”Slender/Compact Hospital Grade”},{“name”:”Horsepower – Maximum”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Wire Size”,”normalizedValue”:”#12 AWG to #10 AWG”,”value”:”#12 AWG to #10 AWG”},{“name”:”Length”,”normalizedValue”:”3.28 in”,”value”:”3.28 in”},{“name”:”Connectivity”,”normalizedValue”:”Back and Side Wired Screw Terminals”,”value”:”Back and Side Wired Screw Terminals”},{“name”:”Wattage”,”normalizedValue”:”2500 W”,”value”:”2500 W”},{“name”:”Display Size”,”normalizedValue”:”Slender/Compact”,”value”:”Slender/Compact”},{“name”:”Style”,”normalizedValue”:”Finder Groove Face”,”value”:”Finder Groove Face”},{“name”:”Dimensions”,”normalizedValue”:”3.28 in x 1.33 in x 1.05 in”,”value”:”3.28 in x 1.33 in x 1.05 in”},{“name”:”Performance”,”normalizedValue”:”Electrical – Current Interrupting – Certified for current interrupting at full rated current Electrical – Dielectric Voltage – Withstands 2,000V minimum Environmental – Flammability – UL 94 V-0 Environmental – Operating Temperatures – Maximum continuous 75°C, minimum -40°C (w/o impact) Mechanical – Product Identification – Ratings are a permanent part of the device Mechanical – Terminal Accommodation – #12-#10 AWG stranded or solid copper wire only Mechanical – Terminal Identification – Terminals identified in accordance with UL 498 and CSA”,”value”:”Electrical – Current Interrupting – Certified for current interrupting at full rated current\nElectrical – Dielectric Voltage – Withstands 2,000V minimum\nEnvironmental – Flammability – UL 94 V-0\nEnvironmental – Operating Temperatures – Maximum continuous 75°C, minimum -40°C (w/o impact)\nMechanical – Product Identification – Ratings are a permanent part of the device\nMechanical – Terminal Accommodation – #12-#10 AWG stranded or solid copper wire only\nMechanical – Terminal Identification – Terminals identified in accordance with UL 498 and CSA”},{“name”:”Industry Standard(s)”,”normalizedValue”:”CSA Certified, C22.2, No. 42 File 285 Fed. Spec. W-C-596 NEMA® WD-6 Compliant UL Listed to UL498 File No. E2186″,”value”:”CSA Certified, C22.2, No. 42 File 285\nFed. Spec. W-C-596\nNEMA® WD-6 Compliant\nUL Listed to UL498 File No. E2186″},{“name”:”Environmental Conditions”,”normalizedValue”:”Indoor Dry Unless Protected By Additional Means”,”value”:”Indoor Dry Unless Protected By Additional Means”},{“name”:”Dielectric Strength”,”normalizedValue”:”Withstands 2,000V minimum”,”value”:”Withstands 2,000V minimum”},{“name”:”Material – Mounting Hardware”,”normalizedValue”:”Screw Mounting”,”value”:”Screw Mounting”},{“name”:”Operating Temperature”,”normalizedValue”:”Maximum continuous 75°C and minimum -40°C without Impact”,”value”:”Maximum continuous 75°C and minimum -40°C without Impact”},{“name”:”Series”,”normalizedValue”:”Hospital Grade”,”value”:”Hospital Grade”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Straight Blade Receptacle, 5-20R, 20 A, 125V AC, 2 Pole, 3 Wire, Flush Mount, Single”