Straight Blade Receptacle, 5-20R, 20 A, 125V AC, 2 Pole, 3 Wire, Flush Mount, Single

$31,39

HBL® Extra Heavy Duty Max Hospital Grade Devices – UL requirements for Hospital Grade devices is more stringent than those for standard devices. Hubbell receptacles are designed to meet and exceed the standards with Exclusive nickel-plated bypass contact design increases contact pressure, lowering the operating temperature; Four point grounding system provides redundant grounding for low resistance ground continuity in high abuse areas; Impact resistant deep face design prevents breakage. Because of these features and others, the benefit is performance, reliability and value for any health care facility.
• Slender/compact design
• Impact-resistant finder groove face
• Triple wipe contacts

9999 in stock

SKU: GRG1254802 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Straight Blade Receptacle”,”rank”:1,”value”:”Straight Blade Receptacle”},{“name”:”Receptacle Type”,”normalizedValue”:”Duplex”,”rank”:2,”value”:”Duplex”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-20R”,”rank”:3,”value”:”5-20R”},{“name”:”Current Rating”,”normalizedValue”:”20 A”,”rank”:4,”value”:”20 A”},{“name”:”Voltage Rating”,”normalizedValue”:”125V AC”,”rank”:5,”value”:”125V AC”},{“name”:”Phase”,”normalizedValue”:”Single”,”rank”:6,”value”:”Single”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:7,”value”:”2″},{“name”:”Number of Wires”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Wire Connection Type”,”normalizedValue”:”Screw Terminals”,”rank”:9,”value”:”Screw Terminals”},{“name”:”Wiring Method”,”normalizedValue”:”Side, Back”,”rank”:10,”value”:”Back, Side”},{“name”:”Grounding”,”normalizedValue”:”Grounded”,”rank”:11,”value”:”Grounded”},{“name”:”Housing Color”,”normalizedValue”:”Brown”,”rank”:12,”value”:”Brown”},{“name”:”Mount Type”,”normalizedValue”:”Flush”,”rank”:13,”value”:”Flush”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”rank”:14,”value”:”IP20″},{“name”:”Standards”,”normalizedValue”:”CSA Certified C22.2 No. 42 File 285, Federal Specification W-C-596, NEMA WD-6, UL 498 File E2186″,”rank”:15,”value”:”CSA Certified C22.2 No. 42 File 285, Federal Specification W-C-596, NEMA WD-6, UL 498 File E2186″},{“name”:”Resistance Properties”,”normalizedValue”:”Impact Resistant”,”rank”:16,”value”:”Impact Resistant”},{“name”:”Flange Type”,”normalizedValue”:”Non-Flanged”,”rank”:17,”value”:”Non-Flanged”},{“name”:”Tamper Resistant”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Weather Resistant”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Color”,”normalizedValue”:”Brown”,”value”:”Brown”},{“name”:”Outlet Type”,”normalizedValue”:”Duplex”,”value”:”Duplex”},{“name”:”Description”,”normalizedValue”:”Compact, Slender”,”value”:”Slender/Compact”},{“name”:”Application Environment”,”normalizedValue”:”Heavy Use Hospital Grade”,”value”:”Heavy Use Hospital Grade”},{“name”:”Number of Gangs”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Mounting Type”,”normalizedValue”:”Flush”,”value”:”Flush”},{“name”:”Wiring Method – Plugs and Receptacles”,”normalizedValue”:”Side, Back”,”value”:”Back and Side”},{“name”:”Surge Suppression”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Sub-Category”,”normalizedValue”:”Duplex Receptacles”,”value”:”Duplex Receptacles”},{“name”:”Weather Resistant – Plugs and Receptacles”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Outlet Type – Plugs and Receptacles”,”normalizedValue”:”Standard Duplex”,”value”:”Standard Duplex”},{“name”:”Mounting Type – Plugs and Receptacles”,”normalizedValue”:”Flush”,”value”:”Flush”},{“name”:”Amps”,”normalizedValue”:”20″,”value”:”20″},{“name”:”HP”,”normalizedValue”:”1 hp”,”value”:”1 hp”},{“name”:”Material”,”normalizedValue”:”Thermoplastic”,”value”:”Thermoplastic”},{“name”:”Series”,”normalizedValue”:”Hospital Grade”,”value”:”Hospital Grade”},{“name”:”Display Size”,”normalizedValue”:”Slender/Compact”,”value”:”Slender/Compact”},{“name”:”Dimensions”,”normalizedValue”:”3.28 in x 1.33 in x 1.05 in”,”value”:”3.28 in x 1.33 in x 1.05 in”},{“name”:”Type”,”normalizedValue”:”Receptacle”,”value”:”Receptacle”},{“name”:”Amperage”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Connectivity”,”normalizedValue”:”Back and Side Wired Screw Terminals”,”value”:”Back and Side Wired Screw Terminals”},{“name”:”Nema Rating”,”normalizedValue”:”5-20R”,”value”:”5-20R”},{“name”:”Style”,”normalizedValue”:”Finder Groove Face”,”value”:”Finder Groove Face”},{“name”:”Wire Size”,”normalizedValue”:”#12 AWG to #10 AWG”,”value”:”#12 AWG to #10 AWG”},{“name”:”Maximum Horsepower”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Number Of Wires”,”normalizedValue”:”3-Wire”,”value”:”3-Wire”},{“name”:”Carton Quantity”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Dielectric Strength”,”normalizedValue”:”Withstands 2,000V minimum”,”value”:”Withstands 2,000V minimum”},{“name”:”Brand”,”normalizedValue”:”Hubbell Wiring Device-Kellems”,”value”:”Hubbell Wiring Device-Kellems”},{“name”:”Surge Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum Wire Size”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”For Location”,”normalizedValue”:”Indoor”,”value”:”Indoor”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Mount Hole Center-to-Center Height”,”normalizedValue”:”3.3 in”,”value”:”3.3 in”},{“name”:”Includes”,”normalizedValue”:”Grounding Staple, Mounting Hardware, Wall Plate or Weatherproof Cover”,”value”:”Grounding Staple, Mounting Hardware, Wall Plate or Weatherproof Cover”},{“name”:”Face Plate Width”,”normalizedValue”:”1.3 in”,”value”:”1.3 in”},{“name”:”Overall Depth”,”normalizedValue”:”1.1 in”,”value”:”1.1 in”},{“name”:”Connection Orientation”,”normalizedValue”:”Straight”,”value”:”Straight”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”167 deg F”,”value”:”167 Degrees F”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”1″,”value”:”1″},{“name”:”UL 94 Flammability Rating”,”normalizedValue”:”V-0″,”value”:”V-0″},{“name”:”GFCI”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Includes Mounting Hardware”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Face Plate Height”,”normalizedValue”:”2.7 in”,”value”:”2.7 in”},{“name”:”Maximum Wire Size”,”normalizedValue”:”10 AWG”,”value”:”10 AWG”},{“name”:”Housing Material”,”normalizedValue”:”Thermoplastic”,”value”:”Thermoplastic”},{“name”:”Horsepower Rating”,”normalizedValue”:”1 HP”,”value”:”1 hp”},{“name”:”Cover Type”,”normalizedValue”:”No Cover”,”value”:”No Cover”},{“name”:”Shrouded”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Polarized”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Grade”,”normalizedValue”:”Hospital Grade Fed. Spec.”,”value”:”Hospital Grade Fed. Spec.”},{“name”:”Market”,”normalizedValue”:”Commercial”,”value”:”Commercial”},{“name”:”AFCI”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Contact Material”,”normalizedValue”:”Brass”,”value”:”Brass”},{“name”:”Terminal Identification”,”normalizedValue”:”Terminals identified in accordance with UL 498 and CSA”,”value”:”Terminals identified in accordance with UL 498 and CSA”},{“name”:”Dielectric Voltage”,”normalizedValue”:”Withstands 2,000V minimum”,”value”:”Withstands 2,000V minimum”},{“name”:”Device Grade”,”normalizedValue”:”Compact Slender”,”value”:”Compact Slender”},{“name”:”Poles and Wires”,”normalizedValue”:”2 Pole, 3 Wire”,”value”:”2 Pole, 3 Wire”},{“name”:”Terminal Accommodation”,”normalizedValue”:”solid copper wire only, #12-#10 AWG stranded”,”value”:”#12-#10 AWG stranded or solid copper wire only”},{“name”:”Device Color”,”normalizedValue”:”Brown”,”value”:”Brown”},{“name”:”Flammability”,”normalizedValue”:”UL 94 V-0″,”value”:”UL 94 V-0″},{“name”:”Certifications”,”normalizedValue”:”FED SPEC Listed”,”value”:”FED SPEC Listed”},{“name”:”Current Interrupting”,”normalizedValue”:”Certified for current interrupting at full rated current”,”value”:”Certified for current interrupting at full rated current”},{“name”:”Operating Temperatures”,”normalizedValue”:”Maximum continuous 75°C, minimum -40°C”,”value”:”Maximum continuous 75°C; minimum -40°C (w/o impact)”},{“name”:”Height”,”normalizedValue”:”1.05 in”,”value”:”1.05 in”},{“name”:”Performance”,”normalizedValue”:”Electrical – Current Interrupting – Certified for current interrupting at full rated current Electrical – Dielectric Voltage – Withstands 2,000V minimum Environmental – Flammability – UL 94 V-0 Environmental – Operating Temperatures – Maximum continuous 75°C, minimum -40°C (w/o impact) Mechanical – Product Identification – Ratings are a permanent part of the device Mechanical – Terminal Accommodation – #12-#10 AWG stranded or solid copper wire only Mechanical – Terminal Identification – Terminals identified in accordance with UL 498 and CSA”,”value”:”Electrical – Current Interrupting – Certified for current interrupting at full rated current\nElectrical – Dielectric Voltage – Withstands 2,000V minimum\nEnvironmental – Flammability – UL 94 V-0\nEnvironmental – Operating Temperatures – Maximum continuous 75°C, minimum -40°C (w/o impact)\nMechanical – Product Identification – Ratings are a permanent part of the device\nMechanical – Terminal Accommodation – #12-#10 AWG stranded or solid copper wire only\nMechanical – Terminal Identification – Terminals identified in accordance with UL 498 and CSA”},{“name”:”Application”,”normalizedValue”:”Slender/Compact Hospital Grade”,”value”:”Slender/Compact Hospital Grade”},{“name”:”Horsepower – Maximum”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Width”,”normalizedValue”:”1.33 in”,”value”:”1.33 in”},{“name”:”Wattage”,”normalizedValue”:”2500 W”,”value”:”2500 W”},{“name”:”Material – Mounting Hardware”,”normalizedValue”:”Screw Mounting”,”value”:”Screw Mounting”},{“name”:”Environmental Conditions”,”normalizedValue”:”Indoor Dry Unless Protected By Additional Means”,”value”:”Indoor Dry Unless Protected By Additional Means”},{“name”:”Length”,”normalizedValue”:”3.28 in”,”value”:”3.28 in”},{“name”:”OEM Brand Name”,”normalizedValue”:”Hubbell Wiring Device-Kellems”,”value”:”Hubbell Wiring Device-Kellems”},{“name”:”Operating Temperature”,”normalizedValue”:”Maximum continuous 75°C and minimum -40°C without Impact”,”value”:”Maximum continuous 75°C and minimum -40°C without Impact”},{“name”:”Industry Standard(s)”,”normalizedValue”:”CSA Certified, C22.2, No. 42 File 285 Fed. Spec. W-C-596 NEMA® WD-6 Compliant UL Listed to UL498 File No. E2186″,”value”:”CSA Certified, C22.2, No. 42 File 285\nFed. Spec. W-C-596\nNEMA® WD-6 Compliant\nUL Listed to UL498 File No. E2186″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Straight Blade Receptacle, 5-20R, 20 A, 125V AC, 2 Pole, 3 Wire, Flush Mount, Single”