Description
[{“name”:”Item”,”normalizedValue”:”Straight Blade Receptacle”,”rank”:1,”value”:”Straight Blade Receptacle”},{“name”:”Receptacle Type”,”normalizedValue”:”Quad”,”rank”:2,”value”:”Quad”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”rank”:3,”value”:”5-15R”},{“name”:”Current Rating”,”normalizedValue”:”15 A”,”rank”:4,”value”:”15 A”},{“name”:”Voltage Rating”,”normalizedValue”:”125V AC”,”rank”:5,”value”:”125V AC”},{“name”:”Phase”,”normalizedValue”:”Single”,”rank”:6,”value”:”Single”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:7,”value”:”2″},{“name”:”Number of Wires”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Wire Connection Type”,”normalizedValue”:”Screw Terminals”,”rank”:9,”value”:”Screw Terminals”},{“name”:”Wiring Method”,”normalizedValue”:”Back”,”rank”:10,”value”:”Back”},{“name”:”Grounding”,”normalizedValue”:”Grounded”,”rank”:11,”value”:”Grounded”},{“name”:”Housing Color”,”normalizedValue”:”Brown”,”rank”:12,”value”:”Brown”},{“name”:”Mount Type”,”normalizedValue”:”Surface”,”rank”:13,”value”:”Surface”},{“name”:”Standards”,”normalizedValue”:”CSA Certified, NEMA WD-6, UL 498″,”rank”:15,”value”:”CSA Certified, NEMA WD-6, UL 498″},{“name”:”Resistance Properties”,”normalizedValue”:”Impact Resistant”,”rank”:16,”value”:”Impact Resistant”},{“name”:”Flange Type”,”normalizedValue”:”Non-Flanged”,”rank”:17,”value”:”Non-Flanged”},{“name”:”Outlet Type – Plugs and Receptacles”,”normalizedValue”:”Quad”,”value”:”Quad”},{“name”:”Application Environment”,”normalizedValue”:”Hospital Grade”,”value”:”Hospital Grade”},{“name”:”Weather Resistant – Plugs and Receptacles”,”normalizedValue”:”No”,”value”:”No”},{“name”:”NEMA Receptacle Configuration – Plugs and Receptacles”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Mounting Type”,”normalizedValue”:”Surface”,”value”:”Surface”},{“name”:”Voltage”,”normalizedValue”:”125VAC”,”value”:”125VAC”},{“name”:”Item – Plugs and Receptacles”,”normalizedValue”:”Receptacle”,”value”:”Receptacle”},{“name”:”Color”,”normalizedValue”:”Brown”,”value”:”Brown”},{“name”:”Material”,”normalizedValue”:”polycarbonate”,”value”:”polycarbonate”},{“name”:”Number of Gangs”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Tamper Resistant”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Voltage – Plugs and Receptacles”,”normalizedValue”:”125V AC”,”value”:”125V AC”},{“name”:”Sub-Category”,”normalizedValue”:”Four Outlet Receptacles”,”value”:”Four Outlet Receptacles”},{“name”:”Corrosion Resistant”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Surge Suppression”,”normalizedValue”:”No”,”value”:”No”},{“name”:”HP”,”normalizedValue”:”1/2 hp”,”value”:”1/2 hp”},{“name”:”Wiring Method – Plugs and Receptacles”,”normalizedValue”:”Back”,”value”:”Back”},{“name”:”Mounting Type – Plugs and Receptacles”,”normalizedValue”:”Surface”,”value”:”Surface”},{“name”:”Weather Resistant”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Amps – Plugs and Receptacles”,”normalizedValue”:”15 A”,”value”:”15 A”},{“name”:”Amps”,”normalizedValue”:”15″,”value”:”15″},{“name”:”Outlet Type”,”normalizedValue”:”Quad”,”value”:”Quad”},{“name”:”Color – Plugs and Receptacles”,”normalizedValue”:”Brown”,”value”:”Brown”},{“name”:”Power Indicator”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Height”,”normalizedValue”:”0.92 in”,”value”:”0.92 in”},{“name”:”Width”,”normalizedValue”:”4.3 in”,”value”:”4.3 in”},{“name”:”Type”,”normalizedValue”:”Hospital Grade”,”value”:”Hospital Grade”},{“name”:”Surge Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum Wire Size”,”normalizedValue”:”14 AWG”,”value”:”14 AWG”},{“name”:”Horsepower Rating”,”normalizedValue”:”0.5 HP”,”value”:”1/2 hp”},{“name”:”GFCI”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Polarized”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Housing Material”,”normalizedValue”:”Polycarbonate”,”value”:”Polycarbonate”},{“name”:”Shrouded”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Wire Size”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Number of Outlets”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Cover Type”,”normalizedValue”:”No Cover”,”value”:”No Cover”},{“name”:”Overall Depth”,”normalizedValue”:”0.9 in”,”value”:”0.9 in”},{“name”:”Mount Hole Center-to-Center Width”,”normalizedValue”:”3.4 in”,”value”:”3.4 in”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”167 deg F”,”value”:”167 Degrees F”},{“name”:”Includes”,”normalizedValue”:”4-PLEX Adapter Plate, 4-PLEX Portable Box”,”value”:”4-PLEX Adapter Plate, 4-PLEX Portable Box”},{“name”:”Grade”,”normalizedValue”:”Hospital Grade Fed. Spec.”,”value”:”Hospital Grade Fed. Spec.”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”1″,”value”:”1″},{“name”:”For Location”,”normalizedValue”:”Indoor”,”value”:”Indoor”},{“name”:”UL 94 Flammability Rating”,”normalizedValue”:”V-2″,”value”:”V-2″},{“name”:”Face Plate Width”,”normalizedValue”:”4.3 in”,”value”:”4.3 in”},{“name”:”Face Plate Height”,”normalizedValue”:”4.3 in”,”value”:”4.3 in”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Mount Hole Center-to-Center Height”,”normalizedValue”:”3.4 in”,”value”:”3.4 in”},{“name”:”Contact Material”,”normalizedValue”:”Brass”,”value”:”Brass”},{“name”:”AFCI”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Connection Orientation”,”normalizedValue”:”Straight”,”value”:”Straight”},{“name”:”Terminal Identification”,”normalizedValue”:”Terminals identified in accordance with UL 498 and CSA”,”value”:”Terminals identified in accordance with UL 498 and CSA”},{“name”:”Flammability”,”normalizedValue”:”UL 94V-2″,”value”:”UL 94V-2″},{“name”:”4-Plex Type”,”normalizedValue”:”Standard”,”value”:”Standard”},{“name”:”Dielectric Voltage”,”normalizedValue”:”Withstands 2,000V minimum”,”value”:”Withstands 2,000V minimum”},{“name”:”Current Interrupting”,”normalizedValue”:”Capable of withstanding a fault level of 1000A, per UL498″,”value”:”Capable of withstanding a fault level of 1000A, per UL498″},{“name”:”Device Color”,”normalizedValue”:”Brown”,”value”:”Brown”},{“name”:”Poles and Wires”,”normalizedValue”:”2 Pole, 3 Wire”,”value”:”2 Pole, 3 Wire”},{“name”:”Operating Temperatures”,”normalizedValue”:”Maximum continuous 75°C, minimum -40°C”,”value”:”Maximum continuous 75°C; minimum -40°C (w/o impact)”},{“name”:”Terminal Accommodation”,”normalizedValue”:”#14-#12 AWG copper stranded or solid conductor only”,”value”:”#14-#12 AWG copper stranded or solid conductor only”},{“name”:”Horsepower – Maximum”,”normalizedValue”:”0.5″,”value”:”0.5″},{“name”:”Wattage”,”normalizedValue”:”1875 W”,”value”:”1875 W”},{“name”:”Display Size”,”normalizedValue”:”Standard Sized Product”,”value”:”Standard Sized Product”},{“name”:”Connectivity”,”normalizedValue”:”Terminals”,”value”:”Back Wired Screw Terminals”},{“name”:”Dielectric Strength”,”normalizedValue”:”Withstands 2,000V minimum”,”value”:”Withstands 2,000V minimum”},{“name”:”OEM Brand Name”,”normalizedValue”:”Hubbell Wiring Device-Kellems”,”value”:”Hubbell Wiring Device-Kellems”},{“name”:”Environmental Conditions”,”normalizedValue”:”Indoor Dry Unless Protected By Additional Means”,”value”:”Indoor Dry Unless Protected By Additional Means”},{“name”:”Length”,”normalizedValue”:”4.3 in”,”value”:”4.3 in”},{“name”:”Operating Temperature”,”normalizedValue”:”Maximum continuous 75°C and minimum -40°C without Impact”,”value”:”Maximum continuous 75°C and minimum -40°C without Impact”},{“name”:”Application”,”normalizedValue”:”4-Plex Hospital Grade”,”value”:”4-Plex Hospital Grade”},{“name”:”Series”,”normalizedValue”:”4-Outlet Receptacle”,”value”:”4-Outlet Receptacle”},{“name”:”Material – Mounting Hardware”,”normalizedValue”:”Screw Mounting”,”value”:”Screw Mounting”},{“name”:”Dimensions”,”normalizedValue”:”4.3 in x 4.3 in x 0.92 in”,”value”:”4.3 in x 4.3 in x 0.92 in”},{“name”:”Industry Standard(s)”,”normalizedValue”:”Certified to CSA, C22.2, No. 42 File 285 NEMA® WD-6 Compliant UL Listed to UL498 File No. E2186″,”value”:”Certified to CSA, C22.2, No. 42 File 285\nNEMA® WD-6 Compliant\nUL Listed to UL498 File No. E2186″},{“name”:”Wire Size”,”normalizedValue”:”#14 AWG to #12 AWG”,”value”:”#14 AWG to #12 AWG”},{“name”:”Performance”,”normalizedValue”:”Electrical – Current Interrupting – Capable of withstanding a fault level of 1000A, per UL498 Electrical – Dielectric Voltage – Withstands 2,000V minimum Environmental – Flammability – UL 94V-2 Environmental – Operating Temperatures – Maximum continuous 75°C, minimum -40°C (w/o impact) Mechanical – Product Identification – Ratings are a permanent part of the device Mechanical – Terminal Accommodation – #14-#12 AWG copper stranded or solid conductor only Mechanical – Terminal Identification – Terminals identified in accordance with UL 498 and CSA”,”value”:”Electrical – Current Interrupting – Capable of withstanding a fault level of 1000A, per UL498\nElectrical – Dielectric Voltage – Withstands 2,000V minimum\nEnvironmental – Flammability – UL 94V-2\nEnvironmental – Operating Temperatures – Maximum continuous 75°C, minimum -40°C (w/o impact)\nMechanical – Product Identification – Ratings are a permanent part of the device\nMechanical – Terminal Accommodation – #14-#12 AWG copper stranded or solid conductor only\nMechanical – Terminal Identification – Terminals identified in accordance with UL 498 and CSA”},{“name”:”Nema Rating”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.