Standing Pilot Retrofit Kit, 140,000 BtuH

$403,01

Intermittent Pilot Ignitor Kit, Product Type Intermittent Pilot Ignitor Kit, Maximum Operating Temperature 175 Degrees F, Minimum Operating Temperature -40 Degrees F, Lock Out Time 90 sec, Pre-Purge Time 6 min, Number of Retries 3, Main Valve Current Output 1 A, Flame Sensor Current Output 0.7 mA, Ignition Cycle Time 90 seconds, Automatic Reset Time 1 hr, Compatible with Series Universal, Compatible with Brand Honeywell, Johnson Controls, Johnstone Supply, Uni-Line, White-Rodgers

Out of stock

SKU: GRG0561951 Category:

Description

[{“name”:”Electrical Ratings”,”normalizedValue”:”24V AC”,”value”:”24V AC”},{“name”:”Prepurge Time (Sec.)”,”normalizedValue”:”360″,”value”:”360 sec”},{“name”:”Lockout Time (Sec.)”,”normalizedValue”:”90″,”value”:”90″},{“name”:”Control Volts”,”normalizedValue”:”24 V”,”value”:”24 V”},{“name”:”Includes”,”normalizedValue”:”722-079 Valve, 780-845 Module, LP Regulator, Mounting Hardware, Spark/Sensor Probe, Wiring Harness”,”value”:”722-079 Valve, 780-845 Module, LP Regulator, Mounting Hardware, Spark/Sensor Probe, Wiring Harness”},{“name”:”Voltage”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Inlet/Outlet (In.)”,”normalizedValue”:”1/2 x 1/2″,”value”:”1/2 X 1/2″},{“name”:”Retries”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Item”,”normalizedValue”:”Intermittent Pilot Ignitor Kit”,”value”:”Intermittent Pilot Ignitor Kit”},{“name”:”Pilot Gas Connection (In.)”,”normalizedValue”:”1/4 in”,”value”:”1/4 in”},{“name”:”Operation Description”,”normalizedValue”:”90 Seconds Of Spark Followed By A Six Minute Time Delay (Purge) Period Between Ignition Attempts. After Three Tries, If No Pilot Flame Is Sensed, Sp845 Goes Into A 1 Hour Lockout Period. At The End Of The 1 Hour Lockout Period, If The Demand For Heat Is Still Present, Unit Repeats The Three Tries For Ignition.”,”value”:”90 Seconds Of Spark Followed By A Six Minute Time Delay (Purge) Period Between Ignition Attempts. After Three Tries, If No Pilot Flame Is Sensed, Sp845 Goes Into A 1 Hour Lockout Period. At The End Of The 1 Hour Lockout Period, If The Demand For Heat Is Still Present, Unit Repeats The Three Tries For Ignition.”},{“name”:”Amps AC”,”normalizedValue”:”1 A”,”value”:”1 A”},{“name”:”BtuH Capacity”,”normalizedValue”:”170,000 / 272,000″,”value”:”170,000 / 272,000″},{“name”:”Electrical Connections”,”normalizedValue”:”1/4 in (Quick Connect)”,”value”:”1/4 in Quick Connect”},{“name”:”Pressure Setting Range (In. WC)”,”normalizedValue”:”3.5 NG / 11.0 LP”,”value”:”3.5 NG / 11.0 LP”},{“name”:”For Use With”,”normalizedValue”:”Residential, Commercial Heating Equipment”,”value”:”Residential, Commercial Heating Equipment”},{“name”:”Type”,”normalizedValue”:”Conversion to Intermittant Pilot Ignition”,”value”:”Conversion to Intermittant Pilot Ignition”},{“name”:”Gas Type”,”normalizedValue”:”LP/NG”,”value”:”LP/NG”},{“name”:”Product Type”,”normalizedValue”:”Intermittent Pilot Ignitor Kit”,”value”:”Intermittent Pilot Ignitor Kit”},{“name”:”Series”,”normalizedValue”:”712″,”value”:”712″},{“name”:”Thermostat Anticipator Setting”,”normalizedValue”:”Thermostat Anticipator”,”value”:”Thermostat Anticipator”},{“name”:”Flame Sensor Current Output”,”normalizedValue”:”0.7 mA”,”value”:”0.7 mA”},{“name”:”Main Valve Current Output”,”normalizedValue”:”1 A”,”value”:”1 A”},{“name”:”Number of Retries”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Control Voltage”,”normalizedValue”:”24V AC”,”value”:”24V AC”},{“name”:”OEM Replacement Part Number”,”normalizedValue”:”10057, 1TGE4, 21D185, 4E397, 63013, 63014, 66201310057, 700-002, 700-007, 700002, 700007, 710-002, 710-007, 710002, 710007, 711002, 711007, 712-007, 712007, L36-987, L36987, L38-185, L38185, Q15GAA-1, Q15GAA1, VLV49A-604R, VLV49A-605R, VLV49A604R, VLV49A605R, Y8610H4010, Y86G1002, Y86G1036″,”value”:”10057, 1TGE4, 21D185, 4E397, 63013, 63014, 66201310057, 700-002, 700-007, 700002, 700007, 710-002, 710-007, 710002, 710007, 711002, 711007, 712-007, 712007, L36-987, L36987, L38-185, L38185, Q15GAA-1, Q15GAA1, VLV49A-604R, VLV49A-605R, VLV49A604R, VLV49A605R, Y8610H4010, Y86G1002, Y86G1036″},{“name”:”Compatible with Brand”,”normalizedValue”:”Honeywell, Johnson Controls, Johnstone Supply, Uni-Line, White-Rodgers”,”value”:”Honeywell, Johnson Controls, Johnstone Supply, Uni-Line, White-Rodgers”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”175 deg F”,”value”:”175 Degrees F”},{“name”:”Pre-Purge Time”,”normalizedValue”:”6 min”,”value”:”6 min”},{“name”:”Compatible with Series”,”normalizedValue”:”Universal”,”value”:”Universal”},{“name”:”Lock Out Time”,”normalizedValue”:”90 sec”,”value”:”90 sec”},{“name”:”Ignition Cycle Time”,”normalizedValue”:”90 seconds”,”value”:”90 seconds”},{“name”:”Automatic Reset Time”,”normalizedValue”:”1 hr”,”value”:”1 hr”},{“name”:”Input Voltage”,”normalizedValue”:”24 V AC”,”value”:”24V AC”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 Degrees F”,”value”:”-40 Degrees F”},{“name”:”For Fuel Type”,”normalizedValue”:”Gas”,”value”:”Natural Gas”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Standing Pilot Retrofit Kit, 140,000 BtuH”