Description
[{“name”:”Size”,”normalizedValue”:”Maximum frame size of 2048 bytes”,”value”:”Maximum frame size of 2048 bytes”},{“name”:”Power / TST”,”normalizedValue”:”This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink fast/slow when in Loopback test mode or hardware error.”,”value”:”This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink fast/slow when in Loopback test mode or hardware error.”},{“name”:”Electrical Safety”,”normalizedValue”:”CAN/CSA C22.2 No. 62368-1-14, EN 62368-1, UL, UL 61010-1, UL 61010-2-201, ULC”,”value”:”UL 61010-1 and UL 61010-2-201 (including CB); UL/ULC/EN 62368-1 (including CB); CAN/CSA C22.2 No. 62368-1-14″},{“name”:”Emissions”,”normalizedValue”:”FCC 47 Part 15 Class A, EN55032 (CISPR32) Class A; ICES-003; EN61000-6-4 (Emissions for industrial environments); CISPR 32:2015/EN 55032:2015 (Class A); CISPR 24:2010/EN 55024:2010; EN61000-3-2″,”value”:”FCC 47 Part 15 Class A, EN55032 (CISPR32) Class A; ICES-003; EN61000-6-4 (Emissions for industrial environments); CISPR 32:2015/EN 55032:2015 (Class A); CISPR 24:2010/EN 55024:2010; EN61000-3-2″},{“name”:”Dimensions”,”normalizedValue”:”114 x 100 x 22.5mm, 4.5 x 3.9 x 0.88 inches”,”value”:”114 x 100 x 22.5mm, 4.5 x 3.9 x 0.88 inches”},{“name”:”Auto-Negotiation”,”normalizedValue”:”Auto (Default – Up): In this mode of operation the media converter will negotiate Ethernet parameters on the copper connection. This will ensure the most optimal connection parameters will be in effect. If the copper link partner does not support Auto negotiation, the media converter will default to 100 Mbps and Half Duplex mode; Off: Auto Negotiation should only be turned off, if the copper link partner does not support Auto Negotiation. When the Auto Negotiation switch is set to the OFF position, the media converter will operate at 100 Mbps and Full Duplex mode.”,”value”:”Auto (Default – Up): In this mode of operation the media converter will negotiate Ethernet parameters on the copper connection. This will ensure the most optimal connection parameters will be in effect. If the copper link partner does not support Auto negotiation, the media converter will default to 100 Mbps and Half Duplex mode; Off: Auto Negotiation should only be turned off, if the copper link partner does not support Auto Negotiation. When the Auto Negotiation switch is set to the OFF position, the media converter will operate at 100 Mbps and Full Duplex mode.”},{“name”:”Operating Altitude”,”normalizedValue”:”Up to 3,048 meters (10,000 feet)”,”value”:”Up to 3,048 meters (10,000 feet)”},{“name”:”Input Supply Voltage”,”normalizedValue”:”Triple voltage 12 / 24 / 48 VDC (9.6 – 60 VDC) input supporting: a) 2 x Terminal Block power input and; b) 1 x T-Bus power input”,”value”:”Triple voltage 12 / 24 / 48 VDC (9.6 – 60 VDC) input supporting: a) 2 x Terminal Block power input and; b) 1 x T-Bus power input”},{“name”:”Current”,”normalizedValue”:”0.09 A (@ 24VDC)”,”value”:”0.09 A (@ 24VDC)”},{“name”:”Operating temperature”,”normalizedValue”:”-10 C to 60 C (14 F to 140 F)”,”value”:”-10 C to 60 C (14 F to 140 F)”},{“name”:”Laser Safety”,”normalizedValue”:”EN 60825-1:2007″,”value”:”EN 60825-1:2007″},{“name”:”Fiber Optic Cable”,”normalizedValue”:”Multimode: 62.5 / 125, 50/125, 85/125, 100/140 micron; Single Mode: 9/125 micron (ITu-T 625)”,”value”:”Multimode: 62.5 / 125, 50/125, 85/125, 100/140 micron; Single Mode: 9/125 micron (ITu-T 625)”},{“name”:”Pause”,”normalizedValue”:”Auto (Deafult-Up): When Auto Negotiation has been set to Auto, the media converter will use this setting for its Ethernet parameter negotiation on the copper connection; Half: The media converter will not negotiate support for the Pause feature.”,”value”:”Auto (Deafult-Up): When Auto Negotiation has been set to Auto, the media converter will use this setting for its Ethernet parameter negotiation on the copper connection; Half: The media converter will not negotiate support for the Pause feature.”},{“name”:”Magnetic Isolation”,”normalizedValue”:”1.5kv”,”value”:”1.5kv”},{“name”:”Fixed Fiber”,”normalizedValue”:”Dual multimode or single mode ( Duplex ) fiber – SC, ST; Single strand fiber ( Simplex ) – SC, ST”,”value”:”Dual multimode or single mode ( Duplex ) fiber – SC, ST; Single strand fiber ( Simplex ) – SC, ST”},{“name”:”Storage temperature”,”normalizedValue”:”-25 C to 70 C (-13 F to 158 F)”,”value”:”-25 C to 70 C (-13 F to 158 F)”},{“name”:”Operating Humidity”,”normalizedValue”:”5% to 90% non-condensing”,”value”:”5% to 90% non-condensing”},{“name”:”Power Consumption”,”normalizedValue”:”2.16 watts (@ 24VDC)”,”value”:”2.16 watts (@ 24VDC)”},{“name”:”100Base-TX”,”normalizedValue”:”RJ45 connector, 2 pair CAT 5 (UTP or STP) or better cable”,”value”:”RJ45 connector, 2 pair CAT 5 (UTP or STP) or better cable”},{“name”:”Filtering”,”normalizedValue”:”1024 MAC Addresses”,”value”:”1024 MAC Addresses”},{“name”:”Power Connector”,”normalizedValue”:”Terminal Block”,”value”:”Dual input Terminal Block and/or T-Bus”},{“name”:”Loopback”,”normalizedValue”:”Disabled (Default-Up): The loopback feature is disabled. This is the normal position for regular operation. The switch must be set to this position for data to pass through the media converter; Enabled: This is a test mode. All data received on the receive (RX) fiber connection is looped back to the transmit (TX) fiber connection. The state of the copper is not relevant and no data or link status is passed through to the copper side.”,”value”:”Disabled (Default-Up): The loopback feature is disabled. This is the normal position for regular operation. The switch must be set to this position for data to pass through the media converter; Enabled: This is a test mode. All data received on the receive (RX) fiber connection is looped back to the transmit (TX) fiber connection. The state of the copper is not relevant and no data or link status is passed through to the copper side.”},{“name”:”Buffer”,”normalizedValue”:”512 Kbits frame buffer memory”,”value”:”512 Kbits frame buffer memory”},{“name”:”Din Rail Kit”,”normalizedValue”:”Native”,”value”:”Native”},{“name”:”Storage Humidity”,”normalizedValue”:”5% to 95% non-condensing”,”value”:”5% to 95% non-condensing”},{“name”:”MTBF (Hours)”,”normalizedValue”:”694,621″,”value”:”694,621 (Calculation model based on MIL-HDBK-217-FN2 @ 30 °C)”},{“name”:”Smart Link Pass-Through”,”normalizedValue”:”Smart Link Pass-Through (Default – Up): In this mode, the link state on one connection is directly reflected through the media converter to the other connection. If link is lost on one of the connections, then the other link will be brought down by the media converter. If the installation has a media converter on both ends of the fiber link and both are setup for Link Pass-Through, then a loss of copper link on the far end device will propagate through both media converters and will result in a loss of copper link at the near end device. This would, therefore, resemble a direct copper connection; Standard Mode (Down): In this mode, the links on the fiber and copper sides can be brought up and down independently of each other. A loss of link on either the fiber ports or copper ports can take place without affecting the other connection”,”value”:”Smart Link Pass-Through (Default – Up): In this mode, the link state on one connection is directly reflected through the media converter to the other connection. If link is lost on one of the connections, then the other link will be brought down by the media converter. If the installation has a media converter on both ends of the fiber link and both are setup for Link Pass-Through, then a loss of copper link on the far end device will propagate through both media converters and will result in a loss of copper link at the near end device. This would, therefore, resemble a direct copper connection; Standard Mode (Down): In this mode, the links on the fiber and copper sides can be brought up and down independently of each other. A loss of link on either the fiber ports or copper ports can take place without affecting the other connection”},{“name”:”Heat Output ( BTU/HR )”,”normalizedValue”:”7.37″,”value”:”7.37″},{“name”:”Bit Error Rate (BER)”,”normalizedValue”:”<10-12","value":"<10-12"},{"name":"Fiber link on / Receive activity (LKF)","normalizedValue":"On: Fiber link present. Blinking slowly: Fiber link disabled because of copper link loss. Blinking quickly: Fiber link present and receiving data. Off: No fiber link present","value":"On: Fiber link present. Blinking slowly: Fiber link disabled because of copper link loss. Blinking quickly: Fiber link present and receiving data. Off: No fiber link present"},{"name":"Immunity","normalizedValue":"EN 61000-4-11, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-6-2, EN55024; EN 61000-4-2, IEC","value":"EN55024; EN 61000-4-2 (ESD); EN 61000-4-3 (RS); EN 61000-4-4 (EFT); EN 61000-4-5 (Surge); EN 61000-4-6 (CS); EN 61000-4-8 (PFMF); EN 61000-4-11; IEC/EN 61000-6-2 (General Immunity for Industrial Environments)"},{"name":"Copper link on / Receive activity (LKC)","normalizedValue":"On: Copper link is present. Blinking quickly: Copper link present and receiving data. Blinking slowly: Copper link disabled because of fiber link loss. Off: No copper link present","value":"On: Copper link is present. Blinking quickly: Copper link present and receiving data. Blinking slowly: Copper link disabled because of fiber link loss. Off: No copper link present"},{"name":"Chassis","normalizedValue":"Molded plastic DIN Rail case with an IP20 ingress protection rating","value":"Molded plastic DIN Rail case with an IP20 ingress protection rating"},{"name":"Country of Origin (subject to change)","normalizedValue":"Taiwan, Province of China","value":"Taiwan, Province of China"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews
There are no reviews yet.