Description
[{“name”:”Amps AC”,”normalizedValue”:”1.5 A”,”value”:”1.5 A”},{“name”:”Retries”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Electrical Ratings”,”normalizedValue”:”Combined Load 1.5 at .4 PF, Flame Sensor Current .7 mA DC @ 25C / 24V AC, Main valve 1 amp at .5 PF, Pilot valve 1 amp at .5 PF”,”value”:”Combined Load 1.5 at .4 PF, Flame Sensor Current .7 mA DC @ 25C / 24V AC, Main valve 1 amp at .5 PF, Pilot valve 1 amp at .5 PF”},{“name”:”Lockout Time (Sec.)”,”normalizedValue”:”Three 60 Second Valve Trials Interrupted By A Five Minute Purge Cycle Before 100 Percent Lockout”,”value”:”Three 60 Second Valve Trials Interrupted By A Five Minute Purge Cycle Before 100 Percent Lockout”},{“name”:”Height (In.)”,”normalizedValue”:”5-1/8″,”value”:”5 1/8 in”},{“name”:”For Use With”,”normalizedValue”:”Residential and Commercial Heating Equipment”,”value”:”Residential and Commercial Heating Equipment”},{“name”:”Electrical Connections”,”normalizedValue”:”Terminals”,”value”:”Terminals”},{“name”:”Item”,”normalizedValue”:”Ignition Control”,”value”:”Ignition Control”},{“name”:”Includes”,”normalizedValue”:”Vent Damper Adaptor Assembly”,”value”:”Vent Damper Adaptor Assembly”},{“name”:”Control Volts”,”normalizedValue”:”24 V”,”value”:”24 V AC”},{“name”:”Pressure Setting Range (In. WC)”,”normalizedValue”:”3.5″,”value”:”3.5″},{“name”:”Gas Type”,”normalizedValue”:”NG/LP”,”value”:”NG/LP”},{“name”:”Depth (In.)”,”normalizedValue”:”1-1/4″,”value”:”1 1/4 in”},{“name”:”Width (In.)”,”normalizedValue”:”3-21/32″,”value”:”3 21/32 in”},{“name”:”Prepurge Time (Sec.)”,”normalizedValue”:”45″,”value”:”45 sec”},{“name”:”Voltage”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Type”,”normalizedValue”:”Spark Ignition”,”value”:”Spark Ignition”},{“name”:”Product Type”,”normalizedValue”:”Ignition Control”,”value”:”Ignition Control”},{“name”:”Input Voltage”,”normalizedValue”:”24 V AC”,”value”:”24V AC”},{“name”:”Replacement Type”,”normalizedValue”:”Universal”,”value”:”Universal”},{“name”:”Automatic Reset Time”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Pre-Purge Time”,”normalizedValue”:”45 sec”,”value”:”45 sec”},{“name”:”Overall Depth”,”normalizedValue”:”1-1/4 in”,”value”:”1 1/4 in”},{“name”:”Control Voltage”,”normalizedValue”:”24V AC”,”value”:”24V AC”},{“name”:”Compatible with Brand”,”normalizedValue”:”Butler, Commerical Appliance, Email Ltd, Honeywell, IBM, Johnson Controls, Johnstone Supply, Robertshaw, Uni-Line”,”value”:”Butler, Commerical Appliance, Email Ltd, Honeywell, IBM, Johnson Controls, Johnstone Supply, Robertshaw, Uni-Line”},{“name”:”Series”,”normalizedValue”:”780″,”value”:”780″},{“name”:”Lock Out Time”,”normalizedValue”:”1 min”,”value”:”1 min”},{“name”:”Electrical Connection Type”,”normalizedValue”:”Screw Terminals”,”value”:”Screw Terminals”},{“name”:”Overall Width”,”normalizedValue”:”3-5/8 in”,”value”:”3 5/8 in”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Ignition Cycle Time”,”normalizedValue”:”60 seconds”,”value”:”60 seconds”},{“name”:”Compatible with Series”,”normalizedValue”:”Universal”,”value”:”Universal”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”175 deg F”,”value”:”175 Degrees F”},{“name”:”Thermostat Anticipator Setting”,”normalizedValue”:”Thermostat Anticipator”,”value”:”Thermostat Anticipator”},{“name”:”OEM Replacement Part Number”,”normalizedValue”:”100-802-05, 100-831-04, 100-831-54, 100-831-66, 233-61160-00A, 63539, 64251, 780-736, G770LHC-1, G770MHC-1, G770NHC-1, L38-366, S860C1000, S860D1009, S860D1017, S8610H1020, SJ4002-104, SJ4009-400, SP745-PU-3-60-5″,”value”:”100-802-05, 100-831-04, 100-831-54, 100-831-66, 233-61160-00A, 63539, 64251, 780-736, G770LHC-1, G770MHC-1, G770NHC-1, L38-366, S860C1000, S860D1009, S860D1017, S8610H1020, SJ4002-104, SJ4009-400, SP745-PU-3-60-5″},{“name”:”Number of Retries”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Main Valve Current Output”,”normalizedValue”:”1.5 A”,”value”:”1.5 A”},{“name”:”Overall Height”,”normalizedValue”:”5-1/8 in”,”value”:”5 1/8 in”},{“name”:”Flame Sensor Current Output”,”normalizedValue”:”0.7 mA”,”value”:”0.7 mA”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 Degrees F”,”value”:”-40 Degrees F”},{“name”:”For Fuel Type”,”normalizedValue”:”Gas, LP”,”value”:”LP, Natural Gas”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.