Solid State Relay, 90 to 280VAC, 40A

$83,89

Solid State Relay, Electrical Connection Screw Clamp, Heat Sink Not Included, Input Current 11 mA; 20 mA, Input Voltage 90 to 280V AC, Maximum Output Current with Heat Sink 40 A, Maximum Output Current without Heat Sink Not Recommended, Output Switching Mode Zero Crossing, Output Voltage Range 48 to 530V AC, Standards CE Certified, CSA Certified, UL Listed, Switch Component Type SCR, Current Type AC, Electrical Phase Single, Finger Safe Yes, Mounting Style Panel, Switch Configuration Form A

Out of stock

SKU: GRG2682136 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Solid State Relay”,”rank”:1,”value”:”Solid State Relay”},{“name”:”Voltage Output”,”normalizedValue”:”48 to 480 VAC”,”value”:”48 to 480VAC”},{“name”:”Heat Sink”,”normalizedValue”:”Not Included”,”value”:”Not Included”},{“name”:”Case Color”,”normalizedValue”:”Gray”,”value”:”Gray”},{“name”:”Input or Control Voltage”,”normalizedValue”:”90 to 280 V AC”,”value”:”90 to 280V AC”},{“name”:”Switch Type”,”normalizedValue”:”SCR”,”value”:”SCR”},{“name”:”Item – Relay”,”normalizedValue”:”Solid State Relay”,”value”:”Solid State Relay”},{“name”:”Body Width – Relay”,”normalizedValue”:”1.74 in”,”value”:”1.74 in”},{“name”:”Mounting – Relay”,”normalizedValue”:”Surface”,”value”:”Surface”},{“name”:”Input Power Consumption (Burden)”,”normalizedValue”:”0.2 to 1.0VA”,”value”:”0.2 to 1.0VA”},{“name”:”Overall Height – Relay”,”normalizedValue”:”1.4 in”,”value”:”1.4 in”},{“name”:”Input or Control Voltage Range”,”normalizedValue”:”90 to 280VAC”,”value”:”90 to 280VAC”},{“name”:”Turns On At”,”normalizedValue”:”Zero Cross”,”value”:”Zero Cross”},{“name”:”Body Depth – Relay”,”normalizedValue”:”2.3 in”,”value”:”2.3 in”},{“name”:”Output or Controlled Voltage Range”,”normalizedValue”:”48 to 480 V AC”,”value”:”48 to 480V AC”},{“name”:”Phase”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Finger Safe”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Relay Turns On At”,”normalizedValue”:”Zero Crossing”,”value”:”Zero Crossing”},{“name”:”Body Height – Relay”,”normalizedValue”:”1.4 in”,”value”:”1.4 in”},{“name”:”Standards”,”normalizedValue”:”CE Certified, CSA Certified, UL Listed”,”value”:”CE Certified, CSA Certified, UL Listed”},{“name”:”Input Voltage”,”normalizedValue”:”90 to 280V AC”,”value”:”90 to 280V AC”},{“name”:”Max. Output Amps w/Heat Sink”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Contact Form – Relay”,”normalizedValue”:”SPST-NO”,”value”:”SPST-NO”},{“name”:”Mounting”,”normalizedValue”:”Surface”,”value”:”Surface”},{“name”:”Max. Output w/Heat Sink”,”normalizedValue”:”40 A”,”value”:”40A”},{“name”:”Max. Output Amps Without Heat Sink”,”normalizedValue”:”Not Recommended”,”value”:”Not Recommended”},{“name”:”Mounting Style”,”normalizedValue”:”Panel”,”value”:”Panel”},{“name”:”Depth”,”normalizedValue”:”2.3 in”,”value”:”2.30 in (58.4 mm)”},{“name”:”Height”,”normalizedValue”:”1.39 in”,”value”:”1.39 in (35.3 mm)”},{“name”:”Electrical Connection”,”normalizedValue”:”Screw Clamp”,”value”:”Screw Clamp”},{“name”:”Width”,”normalizedValue”:”1.85 in”,”value”:”1.85 in (47.1 mm)”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Switch Configuration”,”normalizedValue”:”Form A”,”value”:”Form A”},{“name”:”Drop Out Voltage”,”normalizedValue”:”1.6V DC”,”value”:”1.6V DC”},{“name”:”Response Time”,”normalizedValue”:”0.1 msec”,”value”:”0.1 msec”},{“name”:”Body Width”,”normalizedValue”:”1.85 in”,”value”:”1.85 in”},{“name”:”Current Type”,”normalizedValue”:”AC”,”value”:”AC”},{“name”:”Body Depth”,”normalizedValue”:”2.29 in”,”value”:”2.29 in”},{“name”:”Input Current”,”normalizedValue”:”11 mA, 20 mA”,”value”:”11 mA; 20 mA”},{“name”:”Maximum Output Current with Heat Sink”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”176 Degrees F”,”value”:”176 Degrees F”},{“name”:”Dielectric Strength”,”normalizedValue”:”4,000V”,”value”:”4,000V”},{“name”:”Output Voltage Range”,”normalizedValue”:”48 to 530 V AC”,”value”:”48 to 530V AC”},{“name”:”Electrical Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Power Factor”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Status Indicator”,”normalizedValue”:”LED Indicator”,”value”:”Green LED Indicator”},{“name”:”Switch Component Type”,”normalizedValue”:”SCR”,”value”:”SCR”},{“name”:”Output Switching Mode”,”normalizedValue”:”Zero Crossing”,”value”:”Zero Crossing”},{“name”:”Body Height”,”normalizedValue”:”1.38 in”,”value”:”1.38 in”},{“name”:”Weight”,”normalizedValue”:”3.05 oz”,”value”:”3.05 oz”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Series”,”normalizedValue”:”6000 Series”,”value”:”6000 Series”},{“name”:”Maximum Output Current without Heat Sink”,”normalizedValue”:”Not Recommended”,”value”:”Not Recommended”},{“name”:”Voltage Type”,”normalizedValue”:”AC Output”,”value”:”AC Output”},{“name”:”Insulation Resistance”,”normalizedValue”:”1,000 megaohm”,”value”:”1,000 megaohm”},{“name”:”Overall Depth”,”normalizedValue”:”2.29 in”,”value”:”2.29 in”},{“name”:”Range”,”normalizedValue”:”Legacy”,”value”:”Legacy”},{“name”:”Input Current Limits”,”normalizedValue”:”11 mA at 120 V AC typical; 20 mA at 240 V AC”,”value”:”11 mA at 120 V AC typical; 20 mA at 240 V AC”},{“name”:”Insulating Resistance”,”normalizedValue”:”1 GΩ”,”value”:”1 GΩ”},{“name”:”DV/dt”,”normalizedValue”:”500 V/µs off-state at maximum rated voltage”,”value”:”500 V/µs off-state at maximum rated voltage”},{“name”:”Protection Technology”,”normalizedValue”:”Current limiter”,”value”:”Current limiter”},{“name”:”Thermal Resistance”,”normalizedValue”:”0.9°C/W”,”value”:”0.9°C/W”},{“name”:”Contacts Type and Composition”,”normalizedValue”:”NO”,”value”:”NO”},{“name”:”Output Voltage”,”normalizedValue”:”48…530 V AC”,”value”:”48…530 V AC”},{“name”:”Switch Function”,”normalizedValue”:”SPST”,”value”:”SPST”},{“name”:”Input Impedance”,”normalizedValue”:”13000 Ohm”,”value”:”13000 Ohm”},{“name”:”Maximum I²t for fusing”,”normalizedValue”:”1250 A².s 8.3 ms”,”value”:”1250 A².s 8.3 ms”},{“name”:”Ambient Air Temperature for Operation”,”normalizedValue”:”-40 to 176°F (-40 to 80°C)”,”value”:”-40 to 176°F (-40 to 80°C)”},{“name”:”Network Number of Phases”,”normalizedValue”:”1 phase”,”value”:”1 phase”},{“name”:”Switching Device”,”normalizedValue”:”SCR output; Zero voltage switching”,”value”:”SCR output; Zero voltage switching”},{“name”:”Connections Terminals”,”normalizedValue”:”Input screw clamp terminal, 1; Output screw clamp terminals, 1″,”value”:”Input screw clamp terminal, 1; Output screw clamp terminals, 1″},{“name”:”Tightening Torque”,”normalizedValue”:”10 lb.in for input; 20 lb.in for output”,”value”:”10 lb.in for input; 20 lb.in for output”},{“name”:”Ambient Air Temperature for Storage”,”normalizedValue”:”-40 to 257°F (-40 to 125°C)”,”value”:”-40 to 257°F (-40 to 125°C)”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, CE, UL”,”value”:”UL; CSA; CE”},{“name”:”Control Circuit Voltage”,”normalizedValue”:”90…280 V AC”,”value”:”90…280 V AC”},{“name”:”Surge Current”,”normalizedValue”:”625 A 16.6 ms”,”value”:”625 A 16.6 ms”},{“name”:”Screw Type”,”normalizedValue”:”M3.5; M6″,”value”:”M3.5; M6″},{“name”:”Holding Current”,”normalizedValue”:”250 mA”,”value”:”250 mA”},{“name”:”maximum output current”,”normalizedValue”:”40 A AC”,”value”:”40 A AC”},{“name”:”Voltage Drop”,”normalizedValue”:”\u003c1.6 V on-state AC”,”value”:”\u003c1.6 V on-state AC”},{“name”:”Must Release Voltage”,”normalizedValue”:”10 V”,”value”:”10 V”},{“name”:”Local Signalling”,”normalizedValue”:”for input status 1 LED (green)”,”value”:”for input status 1 LED (green)”},{“name”:”Leakage Current”,”normalizedValue”:”10 mA (at off-state)”,”value”:”10 mA at off-state”},{“name”:”Maximum Peak Voltage”,”normalizedValue”:”800 V”,”value”:”800 V”},{“name”:”Maximum I²t for fusing”,”normalizedValue”:”1250 A².s 8.3 ms”,”value”:”1250 A².s 8.3 ms”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Solid State Relay, 90 to 280VAC, 40A”