Description
[{“name”:”Item”,”normalizedValue”:”Solid State Relay”,”rank”:1,”value”:”Solid State Relay”},{“name”:”Switch Type”,”normalizedValue”:”Triac”,”value”:”Triac”},{“name”:”Input or Control Voltage Range”,”normalizedValue”:”3 to 32 VDC”,”value”:”3 to 32VDC”},{“name”:”Max. Output w/Heat Sink”,”normalizedValue”:”8 A”,”value”:”8A”},{“name”:”Phase”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Mounting – Relay”,”normalizedValue”:”DIN Rail”,”value”:”DIN Rail”},{“name”:”Standards”,”normalizedValue”:”CE Certified, CSA Certified, UL Listed”,”value”:”CE Certified, CSA Certified, UL Listed”},{“name”:”Finger Safe”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Mounting”,”normalizedValue”:”DIN”,”value”:”DIN”},{“name”:”Body Height – Relay”,”normalizedValue”:”2.6 in”,”value”:”2.6 in”},{“name”:”Contact Form – Relay”,”normalizedValue”:”SPST-NO”,”value”:”SPST-NO”},{“name”:”Item – Relay”,”normalizedValue”:”Solid State Relay”,”value”:”Solid State Relay”},{“name”:”Input Voltage”,”normalizedValue”:”3 to 32V DC”,”value”:”3 to 32V DC”},{“name”:”Includes”,”normalizedValue”:”Internal Heat Sink”,”value”:”Internal Heat Sink”},{“name”:”Output or Controlled Voltage Range”,”normalizedValue”:”24 to 280 V AC”,”value”:”24 to 280V AC”},{“name”:”Heat Sink”,”normalizedValue”:”Integral”,”value”:”Integral”},{“name”:”Body Depth – Relay”,”normalizedValue”:”0.7 in”,”value”:”0.7 in”},{“name”:”Voltage Output”,”normalizedValue”:”24 to 280 VAC”,”value”:”24 to 280VAC”},{“name”:”Input or Control Voltage”,”normalizedValue”:”3 to 32 V DC”,”value”:”3 to 32V DC”},{“name”:”Input Power Consumption (Burden)”,”normalizedValue”:”0.1W”,”value”:”0.1W”},{“name”:”Turns On At”,”normalizedValue”:”Zero Cross”,”value”:”Zero Cross”},{“name”:”Max. Output Amps w/Heat Sink”,”normalizedValue”:”8 A”,”value”:”8 A”},{“name”:”Max. Output Amps Without Heat Sink”,”normalizedValue”:”8 A (Integral Heat Sink)”,”value”:”8.0 A Integral Heat Sink”},{“name”:”Overall Height – Relay”,”normalizedValue”:”2.6 in”,”value”:”2.6 in”},{“name”:”Relay Turns On At”,”normalizedValue”:”Zero Crossing”,”value”:”Zero Crossing”},{“name”:”Case Color”,”normalizedValue”:”Gray”,”value”:”Gray”},{“name”:”Body Width – Relay”,”normalizedValue”:”3-1/2 in”,”value”:”3.5 in”},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail & Panel”,”value”:”DIN Rail & Panel”},{“name”:”Depth”,”normalizedValue”:”3.54 in”,”value”:”3.54 in (89.83 mm)”},{“name”:”Width”,”normalizedValue”:”0.62 in”,”value”:”0.62 in (15.75 mm)”},{“name”:”Height”,”normalizedValue”:”2.56 in”,”value”:”2.56 in (65 mm)”},{“name”:”Electrical Connection”,”normalizedValue”:”Screw Clamp”,”value”:”Screw Clamp”},{“name”:”Body Height”,”normalizedValue”:”3-1/2 in”,”value”:”3.5 in”},{“name”:”Drop Out Voltage”,”normalizedValue”:”1.6V DC”,”value”:”1.6V DC”},{“name”:”Switch Component Type”,”normalizedValue”:”Triac”,”value”:”Triac”},{“name”:”Dielectric Strength”,”normalizedValue”:”4,000V”,”value”:”4,000V”},{“name”:”Series”,”normalizedValue”:”861 Series”,”value”:”861 Series”},{“name”:”Voltage Type”,”normalizedValue”:”AC Output”,”value”:”AC Output”},{“name”:”Electrical Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Switch Configuration”,”normalizedValue”:”Form A”,”value”:”Form A”},{“name”:”Maximum Output Current with Heat Sink”,”normalizedValue”:”8 A”,”value”:”8 A”},{“name”:”Overall Depth”,”normalizedValue”:”2.6 in”,”value”:”2.6 in”},{“name”:”Input Current”,”normalizedValue”:”30 mA”,”value”:”30 mA”},{“name”:”Output Voltage Range”,”normalizedValue”:”24 to 280 V AC”,”value”:”24 to 280V AC”},{“name”:”Maximum Output Current without Heat Sink”,”normalizedValue”:”8 A”,”value”:”8 A”},{“name”:”Current Type”,”normalizedValue”:”DC”,”value”:”DC”},{“name”:”Output Switching Mode”,”normalizedValue”:”Zero Crossing”,”value”:”Zero Crossing”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-22 deg F”,”value”:”-22 Degrees F”},{“name”:”Body Depth”,”normalizedValue”:”2.6 in”,”value”:”2.6 in”},{“name”:”Response Time”,”normalizedValue”:”0.1 msec”,”value”:”0.1 msec”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”176 Degrees F”,”value”:”176 Degrees F”},{“name”:”Body Width”,”normalizedValue”:”0.62 in”,”value”:”0.62 in”},{“name”:”Weight”,”normalizedValue”:”4.48 oz”,”value”:”4.48 oz”},{“name”:”Status Indicator”,”normalizedValue”:”LED Indicator”,”value”:”Green LED Indicator”},{“name”:”Load Current”,”normalizedValue”:”8 A at nominal load; 5 A incandescent lamp; 3 A motor”,”value”:”8 A at nominal load; 5 A incandescent lamp; 3 A motor”},{“name”:”Mounting Support”,”normalizedValue”:”Panel; DIN rail”,”value”:”Panel; DIN rail”},{“name”:”DV/dt”,”normalizedValue”:”250 V/µs off-state at maximum rated voltage”,”value”:”250 V/µs off-state at maximum rated voltage”},{“name”:”Network Number of Phases”,”normalizedValue”:”1 phase”,”value”:”1 phase”},{“name”:”Connections Terminals”,”normalizedValue”:”Input/output screw clamp terminal 0.00 in² (2.5 mm²) AWG 14)”,”value”:”Input/output screw clamp terminal 0.00 in² (2.5 mm²) AWG 14)”},{“name”:”Maximum I²t for fusing”,”normalizedValue”:”250 A².s 8.3 ms”,”value”:”250 A².s 8.3 ms”},{“name”:”Product Certifications”,”normalizedValue”:”CE; CSA; UL”,”value”:”CE; CSA; UL”},{“name”:”Voltage Drop”,”normalizedValue”:”<1.6 V peak AC; <1.25 V on-state AC","value":"<1.6 V peak AC; <1.25 V on-state AC"},{"name":"Surge Current","normalizedValue":"200 A 1 cycle","value":"200 A 1 cycle"},{"name":"Output Voltage","normalizedValue":"24...280 V AC","value":"24...280 V AC"},{"name":"Ambient Air Temperature for Storage","normalizedValue":"-40 to 212°F (-40 to 100°C)","value":"-40 to 212°F (-40 to 100°C)"},{"name":"Switching Device","normalizedValue":"Triac output","value":"Triac output"},{"name":"Protection Technology","normalizedValue":"Current limiter","value":"Current limiter"},{"name":"Ambient Air Temperature for Operation","normalizedValue":"-22 to 176°F (-30 to 80°C)","value":"-22 to 176°F (-30 to 80°C)"},{"name":"Switch Function","normalizedValue":"SPST","value":"SPST"},{"name":"Overload Current","normalizedValue":"24 A for 1 second","value":"24 A for 1 second"},{"name":"Leakage Current","normalizedValue":"6 mA at off-state 240 V AC","value":"6 mA at off-state 240 V AC"},{"name":"Thermal Resistance","normalizedValue":"2°C/W","value":"2°C/W"},{"name":"Control Circuit Voltage","normalizedValue":"3...32 V DC","value":"3...32 V DC"},{"name":"Input Current Limits","normalizedValue":"30 mA at 32 V DC typical","value":"30 mA at 32 V DC typical"},{"name":"Local Signalling","normalizedValue":"for input status 1 LED (green)","value":"for input status 1 LED (green)"},{"name":"Tightening Torque","normalizedValue":"0.8 N.m for input/output","value":"0.8 N.m for input/output"},{"name":"Protection Type","normalizedValue":"Reverse polarity protection","value":"Reverse polarity protection"},{"name":"Holding Current","normalizedValue":"150 mA","value":"150 mA"},{"name":"maximum output current","normalizedValue":"8 A AC","value":"8 A AC"},{"name":"Must Release Voltage","normalizedValue":"1 V","value":"1 V"},{"name":"Contacts Type and Composition","normalizedValue":"NO","value":"NO"},{"name":"Range","normalizedValue":"Legacy","value":"Legacy"},{"name":"Maximum I²t for fusing","normalizedValue":"250 A².s 8.3 ms","value":"250 A².s 8.3 ms"},{"name":"Country of Origin (subject to change)","normalizedValue":"India","value":"India"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews
There are no reviews yet.