Description
[{“name”:”Item”,”normalizedValue”:”Solid State Relay”,”rank”:1,”value”:”Solid State Relay”},{“name”:”Body Width – Relay”,”normalizedValue”:”1.74 in”,”value”:”1.74 in”},{“name”:”Phase”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Case Color”,”normalizedValue”:”Gray”,”value”:”Gray”},{“name”:”Turns On At”,”normalizedValue”:”Zero Cross”,”value”:”Zero Cross”},{“name”:”Max. Output w/Heat Sink”,”normalizedValue”:”40 A”,”value”:”40A”},{“name”:”Overall Height – Relay”,”normalizedValue”:”1.4 in”,”value”:”1.4 in”},{“name”:”Item – Relay”,”normalizedValue”:”Solid State Relay”,”value”:”Solid State Relay”},{“name”:”Relay Turns On At”,”normalizedValue”:”Zero Crossing”,”value”:”Zero Crossing”},{“name”:”Mounting”,”normalizedValue”:”Surface”,”value”:”Surface”},{“name”:”Finger Safe”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Contact Form – Relay”,”normalizedValue”:”SPST-NO”,”value”:”SPST-NO”},{“name”:”Voltage Output”,”normalizedValue”:”48 to 480 VAC”,”value”:”48 to 480VAC”},{“name”:”Input Voltage”,”normalizedValue”:”4 to 32V DC”,”value”:”4 to 32V DC”},{“name”:”Body Depth – Relay”,”normalizedValue”:”2.3 in”,”value”:”2.3 in”},{“name”:”Heat Sink”,”normalizedValue”:”Not Included”,”value”:”Not Included”},{“name”:”Body Height – Relay”,”normalizedValue”:”1.4 in”,”value”:”1.4 in”},{“name”:”Standards”,”normalizedValue”:”CE Certified, CSA Certified, UL Listed”,”value”:”CE Certified, CSA Certified, UL Listed”},{“name”:”Input or Control Voltage Range”,”normalizedValue”:”3 to 32 VDC”,”value”:”3 to 32VDC”},{“name”:”Max. Output Amps w/Heat Sink”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Input Power Consumption (Burden)”,”normalizedValue”:”0.2W”,”value”:”0.2W”},{“name”:”Max. Output Amps Without Heat Sink”,”normalizedValue”:”Not Recommended”,”value”:”Not Recommended”},{“name”:”Output or Controlled Voltage Range”,”normalizedValue”:”48 to 480 V AC”,”value”:”48 to 480V AC”},{“name”:”Switch Type”,”normalizedValue”:”SCR”,”value”:”SCR”},{“name”:”Input or Control Voltage”,”normalizedValue”:”3 to 32 V DC”,”value”:”3 to 32V DC”},{“name”:”Mounting – Relay”,”normalizedValue”:”Surface”,”value”:”Surface”},{“name”:”Depth”,”normalizedValue”:”2.3 in”,”value”:”2.30 in (58.4 mm)”},{“name”:”Mounting Style”,”normalizedValue”:”Panel”,”value”:”Panel”},{“name”:”Electrical Connection”,”normalizedValue”:”Screw Clamp”,”value”:”Screw Clamp”},{“name”:”Height”,”normalizedValue”:”1.39 in”,”value”:”1.39 in (35.3 mm)”},{“name”:”Width”,”normalizedValue”:”1.85 in”,”value”:”1.85 in (47.1 mm)”},{“name”:”Body Height”,”normalizedValue”:”1.38 in”,”value”:”1.38 in”},{“name”:”Series”,”normalizedValue”:”6000 Series”,”value”:”6000 Series”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”176 Degrees F”,”value”:”176 Degrees F”},{“name”:”Power Factor”,”normalizedValue”:”0.5″,”value”:”0.5″},{“name”:”Body Depth”,”normalizedValue”:”2.29 in”,”value”:”2.29 in”},{“name”:”Switch Configuration”,”normalizedValue”:”Form A”,”value”:”Form A”},{“name”:”Overall Depth”,”normalizedValue”:”2.29 in”,”value”:”2.29 in”},{“name”:”Maximum Output Current with Heat Sink”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Drop Out Voltage”,”normalizedValue”:”1.6V DC”,”value”:”1.6V DC”},{“name”:”Output Switching Mode”,”normalizedValue”:”Zero Crossing”,”value”:”Zero Crossing”},{“name”:”Response Time”,”normalizedValue”:”0.1 msec”,”value”:”0.1 msec”},{“name”:”Maximum Output Current without Heat Sink”,”normalizedValue”:”Not Recommended”,”value”:”Not Recommended”},{“name”:”Electrical Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Input Current”,”normalizedValue”:”5 to 40 mA”,”value”:”5 to 40 mA”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Current Type”,”normalizedValue”:”DC”,”value”:”DC”},{“name”:”Status Indicator”,”normalizedValue”:”LED Indicator”,”value”:”Green LED Indicator”},{“name”:”Dielectric Strength”,”normalizedValue”:”4,000V”,”value”:”4,000V”},{“name”:”Switch Component Type”,”normalizedValue”:”SCR”,”value”:”SCR”},{“name”:”Voltage Type”,”normalizedValue”:”AC Output”,”value”:”AC Output”},{“name”:”Output Voltage Range”,”normalizedValue”:”48 to 530 V AC”,”value”:”48 to 530V AC”},{“name”:”Body Width”,”normalizedValue”:”1.85 in”,”value”:”1.85 in”},{“name”:”Insulation Resistance”,”normalizedValue”:”1,000 megaohm”,”value”:”1,000 megaohm”},{“name”:”Weight”,”normalizedValue”:”3.05 oz”,”value”:”3.05 oz”},{“name”:”Control Circuit Voltage”,”normalizedValue”:”4…32 V DC”,”value”:”4…32 V DC”},{“name”:”Local Signalling”,”normalizedValue”:”for input status 1 LED (green)”,”value”:”for input status 1 LED (green)”},{“name”:”Voltage Drop”,”normalizedValue”:”\u003c1.6 V on-state AC”,”value”:”\u003c1.6 V on-state AC”},{“name”:”Holding Current”,”normalizedValue”:”150 mA”,”value”:”150 mA”},{“name”:”maximum output current”,”normalizedValue”:”40 A AC”,”value”:”40 A AC”},{“name”:”Connections Terminals”,”normalizedValue”:”Input screw clamp terminal, 1; Output screw clamp terminals, 1″,”value”:”Input screw clamp terminal, 1; Output screw clamp terminals, 1″},{“name”:”Input Current Limits”,”normalizedValue”:”5 to 40 mA at 5 V DC typical”,”value”:”5 to 40 mA at 5 V DC typical”},{“name”:”Surge Current”,”normalizedValue”:”625 A 16.6 ms”,”value”:”625 A 16.6 ms”},{“name”:”Tightening Torque”,”normalizedValue”:”10 lb.in for input; 20 lb.in for output”,”value”:”10 lb.in for input; 20 lb.in for output”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, CE, UL”,”value”:”UL; CSA; CE”},{“name”:”Contacts Type and Composition”,”normalizedValue”:”NO”,”value”:”NO”},{“name”:”DV/dt”,”normalizedValue”:”500 V/µs off-state at maximum rated voltage”,”value”:”500 V/µs off-state at maximum rated voltage”},{“name”:”Switch Function”,”normalizedValue”:”SPST”,”value”:”SPST”},{“name”:”Leakage Current”,”normalizedValue”:”10 mA (at off-state)”,”value”:”10 mA at off-state”},{“name”:”Network Number of Phases”,”normalizedValue”:”1 phase”,”value”:”1 phase”},{“name”:”Maximum I²t for fusing”,”normalizedValue”:”1250 A².s 8.3 ms”,”value”:”1250 A².s 8.3 ms”},{“name”:”Range”,”normalizedValue”:”Legacy”,”value”:”Legacy”},{“name”:”Maximum Peak Voltage”,”normalizedValue”:”800 V”,”value”:”800 V”},{“name”:”Must Release Voltage”,”normalizedValue”:”1 V”,”value”:”1 V”},{“name”:”Switching Device”,”normalizedValue”:”SCR output; Zero voltage switching”,”value”:”SCR output; Zero voltage switching”},{“name”:”Insulating Resistance”,”normalizedValue”:”1 GΩ”,”value”:”1 GΩ”},{“name”:”Screw Type”,”normalizedValue”:”M3.5; M6″,”value”:”M3.5; M6″},{“name”:”Output Voltage”,”normalizedValue”:”48…530 V AC”,”value”:”48…530 V AC”},{“name”:”Ambient Air Temperature for Operation”,”normalizedValue”:”-40 to 176°F (-40 to 80°C)”,”value”:”-40 to 176°F (-40 to 80°C)”},{“name”:”Thermal Resistance”,”normalizedValue”:”0.9°C/W”,”value”:”0.9°C/W”},{“name”:”Ambient Air Temperature for Storage”,”normalizedValue”:”-40 to 257°F (-40 to 125°C)”,”value”:”-40 to 257°F (-40 to 125°C)”},{“name”:”Maximum I²t for fusing”,”normalizedValue”:”1250 A².s 8.3 ms”,”value”:”1250 A².s 8.3 ms”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.