120V AC Aluminum Air and Fuel Gas Solenoid Valve, Normally Closed, 2 1/2 in Pipe Size, Redhat, Mfr#: 8215A090 CSA

$1239,99

Solenoid Valve, Valve Ways 2-Way, Valve Starting Configuration Normally Closed, Valve Type High Flow, Nominal Pipe Size 2 1/2 in, Orifice Diameter 3 in, Body Material Aluminum, Coefficient of Volume (Cv) 117, Operating Pressure Differential Air/Inert Gas – Maximum 5 psi, Operating Pressure Differential Fuel Gas – Maximum Not Applicable, Seal Material NBR, Voltage 110V AC, 120V AC, Operating Pressure Differential Fuel Oil – Maximum Not Applicable

9999 in stock

SKU: GRG2317707 Category:

Description

[{“name”:”Pipe Size – Valves”,”normalizedValue”:”2-1/2 in”,”rank”:1,”value”:”2 1/2 in”},{“name”:”Center Line Pipe Center Size”,”normalizedValue”:”7-29/32 in”,”rank”:2,”value”:”7 29/32 in”},{“name”:”Electrical Connections”,”normalizedValue”:”1/2″ Conduit with 18″ Leads”,”rank”:3,”value”:”1/2″ Conduit w/18″ Leads”},{“name”:”Valve Design”,”normalizedValue”:”2-Position, 2-Way”,”rank”:4,”value”:”2-Way/2-Position”},{“name”:”Voltage”,”normalizedValue”:”120V AC”,”rank”:5,”value”:”120V AC”},{“name”:”Item”,”normalizedValue”:”Air and Fuel Gas Solenoid Valve”,”rank”:6,”value”:”Air and Fuel Gas Solenoid Valve”},{“name”:”Orifice Dia.”,”normalizedValue”:”3 in”,”rank”:7,”value”:”3 in”},{“name”:”Valve Configuration”,”normalizedValue”:”Normally Closed”,”rank”:8,”value”:”Normally Closed”},{“name”:”Body Material – Valves”,”normalizedValue”:”Aluminum”,”rank”:9,”value”:”Aluminum”},{“name”:”Environmental Rating – Valves”,”normalizedValue”:”Indoor, Outdoor”,”value”:”Indoor, Outdoor”},{“name”:”Body Material”,”normalizedValue”:”Aluminum”,”value”:”Aluminum”},{“name”:”BtuH”,”normalizedValue”:”5,821,000″,”value”:”5,821,000 BtuH”},{“name”:”Max. Operating Pressure Differential Air/Inert Gas”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”NEMA Rating”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Coefficient of Volume”,”normalizedValue”:”117″,”value”:”117″},{“name”:”Hz”,”normalizedValue”:”50/60″,”value”:”50/60″},{“name”:”Watts”,”normalizedValue”:”28.2″,”value”:”28.2 W”},{“name”:”Min. Operating Pressure Differential”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Ambient Temp. Range”,”normalizedValue”:”32 Degrees to 125 Degrees F”,”value”:”32 Degrees to 125 Degrees F”},{“name”:”Coil Insulation Class”,”normalizedValue”:”F”,”value”:”F”},{“name”:”Overall Height”,”normalizedValue”:”10-1/4 in”,”value”:”10 1/4 in”},{“name”:”Max. Operating Pressure Differential Water”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”Application”,”normalizedValue”:”Air and Vacuum Service”,”value”:”Air and Vacuum Service”},{“name”:”Seal Material – Valves”,”normalizedValue”:”NBR”,”value”:”NBR”},{“name”:”Overall Width”,”normalizedValue”:”7-15/16 in”,”value”:”7 15/16 in”},{“name”:”Valve Ways and Positions”,”normalizedValue”:”2-Position, 2-Way”,”value”:”2-Way/2-Position”},{“name”:”Max. Fluid Temp.”,”normalizedValue”:”125 deg F”,”value”:”125 Degrees F”},{“name”:”Media”,”normalizedValue”:”Air/Fuel Gas”,”value”:”Air/Fuel Gas”},{“name”:”Max. Operating Pressure Differential”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”Pipe Size”,”normalizedValue”:”2 1/2″”,”value”:”2 1/2″”},{“name”:”Seal Material”,”normalizedValue”:”NBR”,”value”:”NBR”},{“name”:”Overall Length”,”normalizedValue”:”7-25/32 in”,”value”:”7 25/32 in”},{“name”:”Standards”,”normalizedValue”:”CSA, UL”,”value”:”CSA, UL”},{“name”:”Coil Enclosure”,”normalizedValue”:”General Purpose”,”value”:”General Purpose No Junction Box and Watertight”},{“name”:”IP Rating”,”normalizedValue”:”IP65″,”value”:”IP65″},{“name”:”Operation Type”,”normalizedValue”:”Direct Acting”,”value”:”Direct Acting”},{“name”:”Center L”e Pipe Center Size”,”normalizedValue”:”7-29/32 in”,”value”:”7 29/32″”},{“name”:”Frequency”,”normalizedValue”:”50 Hz, 60 Hz”,”value”:”50 Hz, 60 Hz”},{“name”:”Gas Capacity”,”normalizedValue”:”5,821,000 BtuH”,”value”:”5,821,000 BtuH”},{“name”:”Operating Pressure Differential Air/Inert Gas – Maximum”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”Operating Pressure Differential Hot Water – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Response Time”,”normalizedValue”:”120 msec”,”value”:”120 msec”},{“name”:”Valve Starting Configuration”,”normalizedValue”:”Normally Closed”,”value”:”Normally Closed”},{“name”:”Operating Pressure Differential Natural Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Environmental Rating”,”normalizedValue”:”Hazardous, Indoor, Outdoor”,”value”:”Hazardous, Indoor, Outdoor”},{“name”:”Thread Type”,”normalizedValue”:”NPT”,”value”:”NPT”},{“name”:”Operating Pressure Differential Light Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Steam – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Wattage”,”normalizedValue”:”28.2 W”,”value”:”28.2 W”},{“name”:”Operating Pressure Differential Liquid CO2 – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Inlet Connection Type”,”normalizedValue”:”NPTF”,”value”:”NPTF”},{“name”:”Operating Pressure Differential Fuel Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Natural Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Air/Inert Gas – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Nominal Pipe Size”,”normalizedValue”:”2-1/2 in”,”value”:”2 1/2 in”},{“name”:”Valve Ways”,”normalizedValue”:”2-Way”,”value”:”2-Way”},{“name”:”Valve Positions”,”normalizedValue”:”2-Position”,”value”:”2-Position”},{“name”:”Valve Type”,”normalizedValue”:”High Flow”,”value”:”High Flow”},{“name”:”Fluid Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Ambient Temperature – Minimum”,”normalizedValue”:”14 deg F”,”value”:”14 Degrees F”},{“name”:”Operating Pressure Differential Steam – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Includes Seal”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Pressure Differential Fuel Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Light Oil – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Operating Pressure Differential Liquid CO2 – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Orifice Diameter”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Operating Pressure Differential Water – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Operating Pressure Differential Hot Water – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Includes Coil”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Pressure Differential Fuel Oil – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Water – Maximum”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”Operating Pressure Differential – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Outlet Connection Type”,”normalizedValue”:”NPTF”,”value”:”NPTF”},{“name”:”For Media”,”normalizedValue”:”Air, Inert Gases, Liquid Propane Gas, Natural Gas, Oxygen”,”value”:”Air, Inert Gases, Liquid Propane Gas, Natural Gas, Oxygen”},{“name”:”Coefficient of Volume (Cv)”,”normalizedValue”:”117″,”value”:”117″},{“name”:”Ambient Temperature – Maximum”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “120V AC Aluminum Air and Fuel Gas Solenoid Valve, Normally Closed, 2 1/2 in Pipe Size, Redhat, Mfr#: 8215A090 CSA”