Description
[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”For Media”,”normalizedValue”:”Air, Inert Gas, Light Oil, Water”,”rank”:1,”value”:”Air, Inert Gas, Light Oil, Water”},{“name”:”Valve Ways”,”normalizedValue”:”3-Way”,”rank”:2,”value”:”3-Way”},{“name”:”Valve Starting Configuration”,”normalizedValue”:”Normally Open”,”rank”:3,”value”:”Normally Open”},{“name”:”Nominal Pipe Size”,”normalizedValue”:”1/4 in”,”rank”:4,”value”:”1/4 in”},{“name”:”Inlet Connection Type”,”normalizedValue”:”NPTF”,”rank”:5,”value”:”NPTF”},{“name”:”Outlet Connection Type”,”normalizedValue”:”NPTF”,”rank”:6,”value”:”NPTF”},{“name”:”Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Valve Type”,”normalizedValue”:”Quick Exhaust”,”rank”:8,”value”:”Quick Exhaust”},{“name”:”Operation Type”,”normalizedValue”:”Pilot Operated”,”rank”:9,”value”:”Pilot Operated”},{“name”:”Seal Material”,”normalizedValue”:”NBR”,”rank”:10,”value”:”NBR”},{“name”:”Operating Pressure Differential – Maximum”,”normalizedValue”:”200 psi Air/Inert Gas, Light Oil, Water”,”rank”:11,”value”:”200 psi Air/Inert Gas, Light Oil, Water”},{“name”:”Operating Pressure Differential – Minimum”,”normalizedValue”:”10 psi Air/Inert Gas, Light Oil, Water”,”rank”:12,”value”:”10 psi Air/Inert Gas, Light Oil, Water”},{“name”:”Item”,”normalizedValue”:”Solenoid Valve”,”rank”:13,”value”:”Solenoid Valve”},{“name”:”Valve Design”,”normalizedValue”:”2-Position, 3-Way”,”value”:”3-Way/2-Position”},{“name”:”Overall Width”,”normalizedValue”:”2 in”,”value”:”2 in”},{“name”:”Electrical Connections”,”normalizedValue”:”1/2 in Conduit with 18 in Leads”,”value”:”1/2 in Conduit with 18 in Leads”},{“name”:”Coil Enclosure”,”normalizedValue”:”Without Junction Box, Watertight”,”value”:”Without Junction Box, Watertight”},{“name”:”IP Rating”,”normalizedValue”:”66″,”value”:”66″},{“name”:”Center Line Pipe Center Size”,”normalizedValue”:”3-9/16 in”,”value”:”3-9/16 in”},{“name”:”Coil Insulation Class”,”normalizedValue”:”F”,”value”:”F”},{“name”:”Overall Length”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Body Material”,”normalizedValue”:”Brass”,”value”:”Brass”},{“name”:”Overall Height”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Standards”,”normalizedValue”:”ATEX, CSA, IEC Ex Zone 1-21, SIL, UL Listed”,”value”:”ATEX, CSA, IEC Ex Zone 1-21, SIL, UL Listed”},{“name”:”Actuator Type”,”normalizedValue”:”Single Air Pilot”,”value”:”Single Air Pilot”},{“name”:”Operating Pressure Differential Natural Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Environmental Rating”,”normalizedValue”:”Corrosive, Indoor, Outdoor”,”value”:”Corrosive, Indoor, Outdoor”},{“name”:”Operating Pressure Differential Fuel Oil – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Air/Inert Gas – Minimum”,”normalizedValue”:”10 psi”,”value”:”10 psi”},{“name”:”Valve Positions”,”normalizedValue”:”2-Position”,”value”:”2-Position”},{“name”:”Operating Pressure Differential Liquid CO2 – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Hot Water – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Light Oil – Maximum”,”normalizedValue”:”200 psi”,”value”:”200 psi”},{“name”:”Operating Pressure Differential Fuel Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Liquid CO2 – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Air/Inert Gas – Maximum”,”normalizedValue”:”200 psi”,”value”:”200 psi”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Orifice Diameter”,”normalizedValue”:”9/32 in”,”value”:”9/32 in”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Wattage”,”normalizedValue”:”6.1 W”,”value”:”6.1 W”},{“name”:”Mounting Orientation”,”normalizedValue”:”Vertical, Horizontal”,”value”:”Horizontal or Vertical”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”4, 4X, 3, 3S, 1, 2″,”value”:”1, 2, 3, 3S, 4, 4X”},{“name”:”Operating Pressure Differential Steam – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Includes Seal”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Pressure Differential Natural Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Includes Coil”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Fluid Temperature – Maximum”,”normalizedValue”:”180 deg F”,”value”:”180°F”},{“name”:”Operating Pressure Differential Light Oil – Minimum”,”normalizedValue”:”10 psi”,”value”:”10 psi”},{“name”:”Coefficient of Volume (Cv)”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Frequency”,”normalizedValue”:”50 Hz, 60 Hz”,”value”:”50 Hz, 60 Hz”},{“name”:”Operating Pressure Differential Water – Minimum”,”normalizedValue”:”10 psi”,”value”:”10 psi”},{“name”:”Operating Pressure Differential Fuel Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Steam – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Hot Water – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Operating Pressure Differential Water – Maximum”,”normalizedValue”:”200 psi”,”value”:”200 psi”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.