Description
[{“name”:”For Media”,”normalizedValue”:”Light Oil, Air, Water”,”rank”:1,”value”:”Light Oil, Air, Water”},{“name”:”Valve Ways”,”normalizedValue”:”3-Way”,”rank”:2,”value”:”3-Way”},{“name”:”Valve Starting Configuration”,”normalizedValue”:”Configurable”,”rank”:3,”value”:”Configurable”},{“name”:”Nominal Pipe Size”,”normalizedValue”:”1/4 in”,”rank”:4,”value”:”1/4 in”},{“name”:”Inlet Connection Type”,”normalizedValue”:”NPTF”,”rank”:5,”value”:”NPTF”},{“name”:”Outlet Connection Type”,”normalizedValue”:”NPTF”,”rank”:6,”value”:”NPTF”},{“name”:”Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Valve Type”,”normalizedValue”:”High Flow”,”rank”:8,”value”:”High Flow”},{“name”:”Seal Material”,”normalizedValue”:”NBR”,”rank”:10,”value”:”NBR”},{“name”:”Operating Pressure Differential – Maximum”,”normalizedValue”:”150 psi Air/Inert Gas, Light Oil, Water”,”rank”:11,”value”:”150 psi Air/Inert Gas, Light Oil, Water”},{“name”:”Operating Pressure Differential – Minimum”,”normalizedValue”:”0 psi Air/Inert Gas, Light Oil, Water”,”rank”:12,”value”:”0 psi Air/Inert Gas, Light Oil, Water”},{“name”:”Item”,”normalizedValue”:”Solenoid Valve”,”rank”:13,”value”:”Solenoid Valve”},{“name”:”Overall Height”,”normalizedValue”:”3-15/16 in”,”value”:”3-15/16 in”},{“name”:”Coil Enclosure”,”normalizedValue”:”Explosion Proof, Watertight”,”value”:”Explosion Proof, Watertight”},{“name”:”Electrical Connections”,”normalizedValue”:”1/2 in Conduit with 18 in Leads”,”value”:”1/2 in Conduit with 18 in Leads”},{“name”:”Overall Length”,”normalizedValue”:”2-3/16 in”,”value”:”2-3/16 in”},{“name”:”Coil Insulation Class”,”normalizedValue”:”F”,”value”:”F”},{“name”:”Body Material”,”normalizedValue”:”Brass”,”value”:”Brass”},{“name”:”Valve Design”,”normalizedValue”:”2-Position, 3-Way”,”value”:”3-Way/2-Position”},{“name”:”Center Line Pipe Center Size”,”normalizedValue”:”2-1/11 in”,”value”:”2-1/11 in”},{“name”:”Overall Width”,”normalizedValue”:”1-3/16 in”,”value”:”1-3/16 in”},{“name”:”Standards”,”normalizedValue”:”CSA, UL Listed”,”value”:”CSA, UL Listed”},{“name”:”Operating Pressure Differential Fuel Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Coefficient of Volume (Cv)”,”normalizedValue”:”0.56″,”value”:”0.56″},{“name”:”Operating Pressure Differential Fuel Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Environmental Rating”,”normalizedValue”:”Hazardous, Indoor, Outdoor”,”value”:”Hazardous, Indoor, Outdoor”},{“name”:”Operating Pressure Differential Air/Inert Gas – Maximum”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Hot Water – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Includes Coil”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Valve Positions”,”normalizedValue”:”2-Position”,”value”:”2-Position”},{“name”:”Operating Pressure Differential Hot Water – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”4, 4X, 3, 3S, 7, 9, 6, 6P”,”value”:”3, 3S, 4, 4X, 6, 6P, 7, 9″},{“name”:”Operating Pressure Differential Light Oil – Maximum”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Operating Pressure Differential Natural Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Light Oil – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Operating Pressure Differential Fuel Oil – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Water – Maximum”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Operating Pressure Differential Steam – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Steam – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Liquid CO2 – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Includes Seal”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Fluid Temperature – Maximum”,”normalizedValue”:”176 deg F”,”value”:”176°F”},{“name”:”Wattage”,”normalizedValue”:”12 W”,”value”:”12 W”},{“name”:”Operating Pressure Differential Water – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Orifice Diameter”,”normalizedValue”:”1/4 in”,”value”:”1/4 in”},{“name”:”Operating Pressure Differential Liquid CO2 – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Natural Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Frequency”,”normalizedValue”:”50 Hz, 60 Hz”,”value”:”50 Hz, 60 Hz”},{“name”:”Operating Pressure Differential Air/Inert Gas – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.