Description
[{“name”:”For Media”,”normalizedValue”:”Steam”,”rank”:1,”value”:”Steam”},{“name”:”Valve Ways”,”normalizedValue”:”2-Way”,”rank”:2,”value”:”2-Way”},{“name”:”Valve Starting Configuration”,”normalizedValue”:”Normally Open”,”rank”:3,”value”:”Normally Open”},{“name”:”Nominal Pipe Size”,”normalizedValue”:”3/4 in”,”rank”:4,”value”:”3/4 in”},{“name”:”Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Valve Type”,”normalizedValue”:”Self-Cleaning”,”rank”:8,”value”:”Self-Cleaning”},{“name”:”Seal Material”,”normalizedValue”:”PPS”,”rank”:10,”value”:”PPS”},{“name”:”Operating Pressure Differential – Maximum”,”normalizedValue”:”15 psi Steam”,”rank”:11,”value”:”15 psi Steam”},{“name”:”Operating Pressure Differential – Minimum”,”normalizedValue”:”0 psi Steam, Water”,”rank”:12,”value”:”0 psi Steam, Water”},{“name”:”Item”,”normalizedValue”:”Solenoid Valve”,”rank”:13,”value”:”Solenoid Valve”},{“name”:”Ambient Temp. Range”,”normalizedValue”:”125 Degrees F”,”value”:”125 Degrees F”},{“name”:”Max. Fluid Temp. Steam”,”normalizedValue”:”250 deg F”,”value”:”250 Degrees F”},{“name”:”Center Line Pipe Center Size”,”normalizedValue”:”3-39/64 in”,”value”:”3-39/64 in”},{“name”:”Electrical Connections”,”normalizedValue”:”1/2 in Conduit with 18 in Leads”,”value”:”1/2 in Conduit with 18 in Leads”},{“name”:”Coil Insulation Class”,”normalizedValue”:”H”,”value”:”H”},{“name”:”Body Material”,”normalizedValue”:”Brass”,”value”:”Brass”},{“name”:”Overall Height”,”normalizedValue”:”4-15/16 in”,”value”:”4-15/16 in”},{“name”:”Valve Design”,”normalizedValue”:”2-Position, 2-Way”,”value”:”2-Way/2-Position”},{“name”:”Coil Enclosure”,”normalizedValue”:”Without Junction Box, Watertight”,”value”:”Without Junction Box, Watertight”},{“name”:”Overall Width”,”normalizedValue”:”2-9/32 in”,”value”:”2-9/32 in”},{“name”:”Overall Length”,”normalizedValue”:”3-7/16 in”,”value”:”3-7/16 in”},{“name”:”Standards”,”normalizedValue”:”UL Listed”,”value”:”UL Listed”},{“name”:”Operating Pressure Differential Steam – Maximum”,”normalizedValue”:”15 psi”,”value”:”15 psi”},{“name”:”Operating Pressure Differential Natural Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Coefficient of Volume (Cv)”,”normalizedValue”:”9.7″,”value”:”9.7″},{“name”:”Operating Pressure Differential Hot Water – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Operating Pressure Differential Hot Water – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”4, 4X, 3, 3S, 1, 2″,”value”:”1, 2, 3, 3S, 4, 4X”},{“name”:”Environmental Rating”,”normalizedValue”:”Indoor, Outdoor”,”value”:”Indoor, Outdoor”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Orifice Diameter”,”normalizedValue”:”1/2 in”,”value”:”1/2 in”},{“name”:”Operating Pressure Differential Natural Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Oil – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Liquid CO2 – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Light Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Includes Coil”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Pressure Differential Fuel Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Water – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Wattage”,”normalizedValue”:”16.1 W”,”value”:”16.1 W”},{“name”:”Valve Positions”,”normalizedValue”:”2-Position”,”value”:”2-Position”},{“name”:”Operating Pressure Differential Water – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Includes Seal”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Pressure Differential Air/Inert Gas – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Ambient Temperature – Maximum”,”normalizedValue”:”125 deg F”,”value”:”125 Degrees F”},{“name”:”Operating Pressure Differential Steam – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Operating Pressure Differential Air/Inert Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Liquid CO2 – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Operating Pressure Differential Light Oil – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Fluid Temperature – Maximum”,”normalizedValue”:”250°F Steam”,”value”:”250°F Steam”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.