Description
[{“name”:”For Media”,”normalizedValue”:”Air, Inert Gas, Light Oil, Water”,”rank”:1,”value”:”Air, Inert Gas, Light Oil, Water”},{“name”:”Valve Ways”,”normalizedValue”:”2-Way”,”rank”:2,”value”:”2-Way”},{“name”:”Valve Starting Configuration”,”normalizedValue”:”Normally Closed”,”rank”:3,”value”:”Normally Closed”},{“name”:”Nominal Pipe Size”,”normalizedValue”:”1/8 in”,”rank”:4,”value”:”1/8 in”},{“name”:”Inlet Connection Type”,”normalizedValue”:”NPTF”,”rank”:5,”value”:”NPTF”},{“name”:”Outlet Connection Type”,”normalizedValue”:”NPTF”,”rank”:6,”value”:”NPTF”},{“name”:”Voltage”,”normalizedValue”:”240V AC”,”rank”:7,”value”:”240V AC”},{“name”:”Valve Type”,”normalizedValue”:”Compact”,”rank”:8,”value”:”Compact”},{“name”:”Operation Type”,”normalizedValue”:”Direct Acting”,”rank”:9,”value”:”Direct Acting”},{“name”:”Seal Material”,”normalizedValue”:”FKM”,”rank”:10,”value”:”FKM”},{“name”:”Operating Pressure Differential – Maximum”,”normalizedValue”:”135 psi Air/Inert Gas, 80 psi Light Oil, 126 psi Water”,”rank”:11,”value”:”135 psi Air/Inert Gas, 80 psi Light Oil, 126 psi Water”},{“name”:”Operating Pressure Differential – Minimum”,”normalizedValue”:”0 psi Air/Inert Gas, Light Oil, Water”,”rank”:12,”value”:”0 psi Air/Inert Gas, Light Oil, Water”},{“name”:”Item”,”normalizedValue”:”Solenoid Valve”,”rank”:13,”value”:”Solenoid Valve”},{“name”:”Body Material”,”normalizedValue”:”Brass”,”value”:”Brass”},{“name”:”Coil Enclosure”,”normalizedValue”:”Without Junction Box, Watertight”,”value”:”Without Junction Box, Watertight”},{“name”:”IP Rating”,”normalizedValue”:”66″,”value”:”66″},{“name”:”Overall Height”,”normalizedValue”:”2 in”,”value”:”2 in”},{“name”:”Overall Width”,”normalizedValue”:”1 in”,”value”:”1 in”},{“name”:”Overall Length”,”normalizedValue”:”1-13/16 in”,”value”:”1-13/16 in”},{“name”:”Electrical Connections”,”normalizedValue”:”DIN”,”value”:”DIN”},{“name”:”Center Line Pipe Center Size”,”normalizedValue”:”1-13/16 in”,”value”:”1-13/16 in”},{“name”:”Coil Insulation Class”,”normalizedValue”:”F”,”value”:”F”},{“name”:”Valve Design”,”normalizedValue”:”2-Position, 2-Way”,”value”:”2-Way/2-Position”},{“name”:”Application”,”normalizedValue”:”Bottling Lines, Heating Equipment, Kitchen Equipment, Laundry”,”value”:”Bottling Lines, Heating Equipment, Kitchen Equipment, Laundry”},{“name”:”Standards”,”normalizedValue”:”CSA, NSF, UL Listed”,”value”:”CSA, NSF, UL Listed”},{“name”:”Operating Pressure Differential Hot Water – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”4, 4X”,”value”:”4, 4X”},{“name”:”Operating Pressure Differential Air/Inert Gas – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Wattage”,”normalizedValue”:”6.3 W”,”value”:”6.3 W”},{“name”:”Orifice Diameter”,”normalizedValue”:”1/8 in”,”value”:”1/8 in”},{“name”:”Operating Pressure Differential Liquid CO2 – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Includes Seal”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Pressure Differential Fuel Oil – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Natural Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Water – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Fluid Temperature – Maximum”,”normalizedValue”:”180 deg F”,”value”:”180°F”},{“name”:”Frequency”,”normalizedValue”:”50 Hz, 60 Hz”,”value”:”50 Hz, 60 Hz”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Includes Coil”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Response Time”,”normalizedValue”:”20 msec”,”value”:”20 msec”},{“name”:”Operating Pressure Differential Fuel Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Light Oil – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Operating Pressure Differential Steam – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Operating Pressure Differential Fuel Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Water – Maximum”,”normalizedValue”:”126 psi”,”value”:”126 psi”},{“name”:”Coefficient of Volume (Cv)”,”normalizedValue”:”2.19″,”value”:”2.19″},{“name”:”Valve Positions”,”normalizedValue”:”2-Position”,”value”:”2-Position”},{“name”:”Mounting Orientation”,”normalizedValue”:”Vertical, Horizontal”,”value”:”Horizontal or Vertical”},{“name”:”Operating Pressure Differential Liquid CO2 – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Light Oil – Maximum”,”normalizedValue”:”80 psi”,”value”:”80 psi”},{“name”:”Operating Pressure Differential Hot Water – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Environmental Rating”,”normalizedValue”:”Indoor”,”value”:”Indoor”},{“name”:”Operating Pressure Differential Natural Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Air/Inert Gas – Maximum”,”normalizedValue”:”135 psi”,”value”:”135 psi”},{“name”:”Thread Type”,”normalizedValue”:”NPT”,”value”:”NPT”},{“name”:”Operating Pressure Differential Steam – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.