Description
[{“name”:”For Media”,”normalizedValue”:”Hot Water, Steam”,”rank”:1,”value”:”Hot Water, Steam”},{“name”:”Valve Ways”,”normalizedValue”:”2-Way”,”rank”:2,”value”:”2-Way”},{“name”:”Valve Starting Configuration”,”normalizedValue”:”Normally Closed”,”rank”:3,”value”:”Normally Closed”},{“name”:”Nominal Pipe Size”,”normalizedValue”:”1/2 in”,”rank”:4,”value”:”1/2 in”},{“name”:”Inlet Connection Type”,”normalizedValue”:”NPTF”,”rank”:5,”value”:”NPTF”},{“name”:”Outlet Connection Type”,”normalizedValue”:”NPTF”,”rank”:6,”value”:”NPTF”},{“name”:”Voltage”,”normalizedValue”:”24V DC”,”rank”:7,”value”:”24V DC”},{“name”:”Valve Type”,”normalizedValue”:”Diaphragm, Piston”,”rank”:8,”value”:”Diaphragm, Piston”},{“name”:”Operation Type”,”normalizedValue”:”Pilot Operated”,”rank”:9,”value”:”Pilot Operated”},{“name”:”Seal Material”,”normalizedValue”:”PTFE”,”rank”:10,”value”:”PTFE”},{“name”:”Operating Pressure Differential – Maximum”,”normalizedValue”:”100 psi Hot Water, 50 psi Steam”,”rank”:11,”value”:”100 psi Hot Water, 50 psi Steam”},{“name”:”Operating Pressure Differential – Minimum”,”normalizedValue”:”0 psi”,”rank”:12,”value”:”0 psi”},{“name”:”Item”,”normalizedValue”:”Solenoid Valve”,”rank”:13,”value”:”Solenoid Valve”},{“name”:”Max. Fluid Temp. Steam”,”normalizedValue”:”300 deg F”,”value”:”300 Degrees F”},{“name”:”Overall Length”,”normalizedValue”:”2-7/8 in”,”value”:”2-7/8 in”},{“name”:”Valve Design”,”normalizedValue”:”Diaphragm”,”value”:”Diaphragm”},{“name”:”Overall Width”,”normalizedValue”:”2-1/4 in”,”value”:”2-1/4 in”},{“name”:”Electrical Connections”,”normalizedValue”:”1/2 in Conduit with 18 in Leads”,”value”:”1/2 in Conduit with 18 in Leads”},{“name”:”Center Line Pipe Center Size”,”normalizedValue”:”3-17/32 in”,”value”:”3-17/32 in”},{“name”:”Coil Insulation Class”,”normalizedValue”:”H”,”value”:”H”},{“name”:”Max. Fluid Temp. Hot Water”,”normalizedValue”:”210 Degrees F”,”value”:”210 Degrees F”},{“name”:”Ambient Temp. Range”,”normalizedValue”:”125 Degrees F”,”value”:”125 Degrees F”},{“name”:”Overall Height”,”normalizedValue”:”4-3/32 in”,”value”:”4-3/32 in”},{“name”:”Coil Enclosure”,”normalizedValue”:”Without Junction Box, Watertight”,”value”:”Without Junction Box, Watertight”},{“name”:”Body Material”,”normalizedValue”:”Brass”,”value”:”Brass”},{“name”:”Standards”,”normalizedValue”:”CSA, UL Listed”,”value”:”CSA, UL Listed”},{“name”:”Application”,”normalizedValue”:”Hot Water, Steam”,”value”:”Hot Water, Steam”},{“name”:”Operating Pressure Differential Liquid CO2 – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Includes Coil”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Ambient Temperature – Maximum”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Operating Pressure Differential Hot Water – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Natural Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Ambient Temperature – Minimum”,”normalizedValue”:”14 deg F”,”value”:”14 Degrees F”},{“name”:”Orifice Diameter”,”normalizedValue”:”1/2 in”,”value”:”1/2 in”},{“name”:”Operating Pressure Differential Light Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Coefficient of Volume (Cv)”,”normalizedValue”:”4.7″,”value”:”4.7″},{“name”:”Operating Pressure Differential Air/Inert Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Liquid CO2 – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Thread Type”,”normalizedValue”:”NPT”,”value”:”NPT”},{“name”:”Operating Pressure Differential Water – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Fluid Temperature – Maximum”,”normalizedValue”:”300°F Steam, 210°F Water”,”value”:”300°F Steam, 210°F Water”},{“name”:”Operating Pressure Differential Steam – Maximum”,”normalizedValue”:”50 psi”,”value”:”50 psi”},{“name”:”Operating Pressure Differential Fuel Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Valve Positions”,”normalizedValue”:”2-Position”,”value”:”2-Position”},{“name”:”Operating Pressure Differential Light Oil – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Operating Pressure Differential Fuel Oil – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Wattage”,”normalizedValue”:”15.6 W”,”value”:”15.6 W”},{“name”:”Operating Pressure Differential Hot Water – Maximum”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Environmental Rating”,”normalizedValue”:”Hazardous, Indoor, Outdoor, Washdown”,”value”:”Hazardous, Indoor, Outdoor, Washdown”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”4, 4X, 3, 3S, 1, 2″,”value”:”1, 2, 3, 3S, 4, 4X”},{“name”:”Operating Pressure Differential Natural Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Steam – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Air/Inert Gas – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.