Description
[{“name”:”For Media”,”normalizedValue”:”Air, Corrosives, Inert Gases, Liquids”,”rank”:1,”value”:”Air, Corrosives, Inert Gases, Liquids”},{“name”:”Valve Ways”,”normalizedValue”:”2-Way”,”rank”:2,”value”:”2-Way”},{“name”:”Valve Starting Configuration”,”normalizedValue”:”Normally Closed”,”rank”:3,”value”:”Normally Closed”},{“name”:”Nominal Pipe Size”,”normalizedValue”:”1/2 in”,”rank”:4,”value”:”1/2 in”},{“name”:”Inlet Connection Type”,”normalizedValue”:”NPTF”,”rank”:5,”value”:”NPTF”},{“name”:”Outlet Connection Type”,”normalizedValue”:”NPTF”,”rank”:6,”value”:”NPTF”},{“name”:”Voltage”,”normalizedValue”:”120V”,”rank”:7,”value”:”120V”},{“name”:”Valve Type”,”normalizedValue”:””,”rank”:8,”value”:”Not Applicable”},{“name”:”Operation Type”,”normalizedValue”:”Direct Acting”,”rank”:9,”value”:”Direct Acting”},{“name”:”Seal Material”,”normalizedValue”:”NBR”,”rank”:10,”value”:”NBR”},{“name”:”Operating Pressure Differential – Maximum”,”normalizedValue”:”350 psi”,”rank”:11,”value”:”350 psi”},{“name”:”Operating Pressure Differential – Minimum”,”normalizedValue”:”0 psi”,”rank”:12,”value”:”0 psi”},{“name”:”Item”,”normalizedValue”:”Solenoid Valve”,”rank”:13,”value”:”Solenoid Valve”},{“name”:”Application”,”normalizedValue”:”Air Compressors, Car Wash Equipment, Industrial Water Control, Laundry Equipment, Pumps”,”value”:”Air Compressors, Car Wash Equipment, Industrial Water Control, Laundry Equipment, Pumps”},{“name”:”Body Material”,”normalizedValue”:”Brass”,”value”:”Brass”},{“name”:”Standards”,”normalizedValue”:”CSA, NSF/ANSI 372, SDWA, UL Listed”,”value”:”CSA, NSF/ANSI 372, SDWA, UL Listed”},{“name”:”Coil Enclosure”,”normalizedValue”:”Watertight”,”value”:”Watertight”},{“name”:”Coil Insulation Class”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Liquid CO2 – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Coefficient of Volume (Cv)”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Environmental Rating”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Orifice Diameter”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Air/Inert Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Gas Capacity”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Water – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Oil – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Hot Water – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Steam – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Fluid Temperature – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Valve Body Style”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Natural Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Thread Type”,”normalizedValue”:”NPT”,”value”:”NPT”},{“name”:”Operating Pressure Differential Steam – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Liquid CO2 – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Ambient Temperature – Maximum”,”normalizedValue”:”125 deg F”,”value”:”125 Degrees F”},{“name”:”Operating Pressure Differential Light Oil – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Fluid Temperature – Minimum”,”normalizedValue”:”0 deg F”,”value”:”0 Degrees F”},{“name”:”Valve Positions”,”normalizedValue”:”2-Position”,”value”:”2-Position”},{“name”:”Operating Pressure Differential Natural Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Water – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Hot Water – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Light Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Air/Inert Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Ambient Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.