Description
[{“name”:”For Media”,”normalizedValue”:”Fuel Oil, Gas”,”rank”:1,”value”:”Fuel Oil, Gas”},{“name”:”Valve Ways”,”normalizedValue”:”2-Way”,”rank”:2,”value”:”2-Way”},{“name”:”Valve Starting Configuration”,”normalizedValue”:”Normally Closed”,”rank”:3,”value”:”Normally Closed”},{“name”:”Nominal Pipe Size”,”normalizedValue”:”1 in”,”rank”:4,”value”:”1 in”},{“name”:”Inlet Connection Type”,”normalizedValue”:”NPTF”,”rank”:5,”value”:”NPTF”},{“name”:”Outlet Connection Type”,”normalizedValue”:”NPTF”,”rank”:6,”value”:”NPTF”},{“name”:”Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Valve Type”,”normalizedValue”:”Test Port”,”rank”:8,”value”:”High Flow Gas Shut Off, Test Port”},{“name”:”Operation Type”,”normalizedValue”:”Direct Acting”,”rank”:9,”value”:”Direct Acting”},{“name”:”Seal Material”,”normalizedValue”:”NBR”,”rank”:10,”value”:”NBR”},{“name”:”Operating Pressure Differential – Maximum”,”normalizedValue”:”5 psi Air/Inert Gas, Fuel Gas, Water”,”rank”:11,”value”:”5 psi Air/Inert Gas, Fuel Gas, Water”},{“name”:”Operating Pressure Differential – Minimum”,”normalizedValue”:”0 psi Fuel Gas”,”rank”:12,”value”:”0 psi Fuel Gas”},{“name”:”Item”,”normalizedValue”:”Solenoid Valve”,”rank”:13,”value”:”Solenoid Valve”},{“name”:”Ambient Temp. Range”,”normalizedValue”:”-40 Degrees to 125 Degrees F”,”value”:”-40 Degrees to 125 Degrees F”},{“name”:”Electrical Connections”,”normalizedValue”:”1/2 in Conduit with 18 in Leads”,”value”:”1/2 in Conduit with 18 in Leads”},{“name”:”Overall Length”,”normalizedValue”:”5-15/16 in”,”value”:”5-15/16 in”},{“name”:”Overall Width”,”normalizedValue”:”5-3/8 in”,”value”:”5-3/8 in”},{“name”:”Standards”,”normalizedValue”:”CSA for Safety Shutoff, FM, UL”,”value”:”CSA for Safety Shutoff, FM, UL”},{“name”:”Center Line Pipe Center Size”,”normalizedValue”:”5-1/2 in”,”value”:”5-1/2 in”},{“name”:”Application”,”normalizedValue”:”For On-Off Control of Fuel Gas in Commercial and Industrial Gas Burners. Has a Visual Indication of Open and Shut Position and Proof of Closure Switch.”,”value”:”For On-Off Control of Fuel Gas in Commercial and Industrial Gas Burners. Has a Visual Indication of Open and Shut Position and Proof of Closure Switch.”},{“name”:”Coil Insulation Class”,”normalizedValue”:”F”,”value”:”F”},{“name”:”Body Material”,”normalizedValue”:”Aluminum”,”value”:”Aluminum”},{“name”:”Valve Design”,”normalizedValue”:”2-Position, 2-Way”,”value”:”2-Way/2-Position”},{“name”:”Overall Height”,”normalizedValue”:”11 in”,”value”:”11 in”},{“name”:”BtuH”,”normalizedValue”:”1,132,300″,”value”:”1,132,300 BtuH”},{“name”:”Coil Enclosure”,”normalizedValue”:”General Purpose, With Junction Box”,”value”:”General Purpose, With Junction Box”},{“name”:”Operating Pressure Differential Fuel Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Thread Type”,”normalizedValue”:”NPT”,”value”:”NPT”},{“name”:”Gas Capacity”,”normalizedValue”:”1,132,300 BtuH”,”value”:”1,132,300 BtuH”},{“name”:”Wattage”,”normalizedValue”:”20 W”,”value”:”20 W”},{“name”:”Operating Pressure Differential Natural Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Natural Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Steam – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Includes Coil”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Pressure Differential Hot Water – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Ambient Temperature – Maximum”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Operating Pressure Differential Liquid CO2 – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Hot Water – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Includes Seal”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Pressure Differential Light Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Steam – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Coefficient of Volume (Cv)”,”normalizedValue”:”21″,”value”:”21″},{“name”:”Operating Pressure Differential Light Oil – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Operating Pressure Differential Fuel Gas – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Valve Positions”,”normalizedValue”:”2-Position”,”value”:”2-Position”},{“name”:”Operating Pressure Differential Air/Inert Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Gas – Maximum”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”Actuator Type”,”normalizedValue”:”Solenoid”,”value”:”Double Solenoid”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Orifice Diameter”,”normalizedValue”:”1-5/8 in”,”value”:”1-5/8 in”},{“name”:”Fluid Temperature – Maximum”,”normalizedValue”:”125 deg F”,”value”:”125°F”},{“name”:”Environmental Rating”,”normalizedValue”:”Indoor, Outdoor”,”value”:”Indoor, Outdoor”},{“name”:”Operating Pressure Differential Liquid CO2 – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Ambient Temperature – Minimum”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Air/Inert Gas – Maximum”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”Operating Pressure Differential Fuel Oil – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Frequency”,”normalizedValue”:”50 Hz, 60 Hz”,”value”:”50 Hz, 60 Hz”},{“name”:”Operating Pressure Differential Water – Maximum”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.