Description
[{“name”:”Width”,”normalizedValue”:”6.9 in”,”value”:”6.9 in”},{“name”:”Height”,”normalizedValue”:”0.9 in”,”value”:”0.9 in”},{“name”:”Depth”,”normalizedValue”:”5.7 in”,”value”:”5.7 in”},{“name”:”Product Type”,”normalizedValue”:”Transceiver/Media Converter”,”value”:”Transceiver/Media Converter”},{“name”:”Number of ST Ports”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Form Factor”,”normalizedValue”:”External”,”value”:”External”},{“name”:”Network Technology”,”normalizedValue”:”100Base-LX, 10/100Base-TX”,”value”:”100Base-LX, 10/100Base-TX”},{“name”:”Environmentally Friendly”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Fiber Optic Cable Standard”,”normalizedValue”:”9/125 µm”,”value”:”9/125 µm”},{“name”:”Management Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Network (RJ-45)”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Distance Supported”,”normalizedValue”:”12.43 mi”,”value”:”12.43 Mile”},{“name”:”Weight (Approximate)”,”normalizedValue”:”1.59 lb”,”value”:”1.59 lb”},{“name”:”Total Number of Ports”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Number of Network (RJ-45) Ports”,”normalizedValue”:”1″,”value”:”1″},{“name”:”ST Port Type”,”normalizedValue”:”Duplex”,”value”:”Duplex”},{“name”:”Product Name”,”normalizedValue”:”SMI-100-S2ST20 Fast Ethernet Media Converter”,”value”:”SMI-100-S2ST20 Fast Ethernet Media Converter”},{“name”:”Immunity”,”normalizedValue”:”EN55024″,”value”:”EN55024″},{“name”:”Auto-MDIX (Strap)”,”normalizedValue”:”If Auto-Negotiation (802.3u) is enabled, the media converter uses the HP Auto-MDIX method for the 100Base-TX interface. If Auto-Negotiation (802.3u) is disabled the Media converter will use the RX Energy method on the 100Base-TX interface to set the port MDI or MDIX whichever is appropriate; Enabled (Default)- Either a straight-through or crossover type cable can be used to connect the media converter to the device on the other end of the cable; Disabled- If the partner device on the other end of the cable does not have the Auto-MDIX feature a specific cable, either a straight-through or crossover will be required to ensure that the media convertor’s transmitter and the partner devices transmitter are connected to the others receiver. The Media Convertor’s 100Base-TX port is configured as MDI with this switch setting.”,”value”:”If Auto-Negotiation (802.3u) is enabled, the media converter uses the HP Auto-MDIX method for the 100Base-TX interface. If Auto-Negotiation (802.3u) is disabled the Media converter will use the RX Energy method on the 100Base-TX interface to set the port MDI or MDIX whichever is appropriate; Enabled (Default)- Either a straight-through or crossover type cable can be used to connect the media converter to the device on the other end of the cable; Disabled- If the partner device on the other end of the cable does not have the Auto-MDIX feature a specific cable, either a straight-through or crossover will be required to ensure that the media convertor’s transmitter and the partner devices transmitter are connected to the others receiver. The Media Convertor’s 100Base-TX port is configured as MDI with this switch setting.”},{“name”:”Pause”,”normalizedValue”:”Pause should be enabled when all devices connected to the media converter support pause. Auto-Negotiation must be Enabled to use this feature; Enabled (Default)- The Media converter will advertise Pause capability during Auto-Negotiation on the 100Base-TX interface; Disabled- The Media converter will advertise that it does not have Pause capability during Auto-Negotiation on the 100Base-TX interface.”,”value”:”Pause should be enabled when all devices connected to the media converter support pause. Auto-Negotiation must be Enabled to use this feature; Enabled (Default)- The Media converter will advertise Pause capability during Auto-Negotiation on the 100Base-TX interface; Disabled- The Media converter will advertise that it does not have Pause capability during Auto-Negotiation on the 100Base-TX interface.”},{“name”:”Power Connector”,”normalizedValue”:”5.5mm x 9.5mm x 2.1mm barrel socket”,”value”:”5.5mm x 9.5mm x 2.1mm barrel socket”},{“name”:”Input Supply Voltage”,”normalizedValue”:”( 12 vDC Nominal )”,”value”:”( 12 vDC Nominal )”},{“name”:”Copper link on / Receive activity (LKC)”,”normalizedValue”:”This green LED is operational only when power is applied; The LED is on when the 100Base-TX link is on and flashes with a 50% duty cycle when data is received.”,”value”:”This green LED is operational only when power is applied; The LED is on when the 100Base-TX link is on and flashes with a 50% duty cycle when data is received.”},{“name”:”Dimentions”,”normalizedValue”:”175 mm x 145 mm x 23 mm”,”value”:”175 x 145 x 23 mm”},{“name”:”Laser Safety”,”normalizedValue”:”EN 60825-1:2007″,”value”:”EN 60825-1:2007″},{“name”:”100Base-TX”,”normalizedValue”:”RJ45 connector, 2 pair CAT 5, EIA/TIA 568A/B or better cable; Magnetic Isolation – 1.5kv”,”value”:”RJ45 connector, 2 pair CAT 5, EIA/TIA 568A/B or better cable; Magnetic Isolation – 1.5kv”},{“name”:”Auto-Negotiation (802.3u)”,”normalizedValue”:”Enabled (Default)- The media converter uses 802.3u Auto-negotiation on the 100Base-TX interface. It is set to advertise full duplex; Disabled- The media converter sets the 100Base-TX port to full duplex.”,”value”:”Enabled (Default)- The media converter uses 802.3u Auto-negotiation on the 100Base-TX interface. It is set to advertise full duplex; Disabled- The media converter sets the 100Base-TX port to full duplex.”},{“name”:”Fiber Optic Cable”,”normalizedValue”:”Single mode dual ST Media Converters; Multimode: 62.5 / 125, 50/125, 85/125, 100/140 micron; Single Mode: 9/125 micron (ITU-T 625)”,”value”:”Single mode dual ST Media Converters; Multimode: 62.5 / 125, 50/125, 85/125, 100/140 micron; Single Mode: 9/125 micron (ITU-T 625)”},{“name”:”Power”,”normalizedValue”:”Blinking green during startup cycle Steady green: module has power and is ready; Red : error”,”value”:”Blinking green during startup cycle Steady green: module has power and is ready; Red : error”},{“name”:”Emissions”,”normalizedValue”:”FCC Part 15 Class B*, EN55022 Class B*”,”value”:”FCC Part 15 Class B*, EN55022 Class B*”},{“name”:”Remote Loopback”,”normalizedValue”:”The media converter can perform a loopback on the 100Base-X fiber interface; Disabled (Default – Up); Enabled- The 100Base-X receiver is looped to the 100Base-X transmitter. The 100Base-TX transmitter is taken off the interface.”,”value”:”The media converter can perform a loopback on the 100Base-X fiber interface; Disabled (Default – Up); Enabled- The 100Base-X receiver is looped to the 100Base-X transmitter. The 100Base-TX transmitter is taken off the interface.”},{“name”:”Configuration Mode (Strap)”,”normalizedValue”:”Switch – Use onboard DIP switches, Auto enable management module to overwrite hardware switch settings”,”value”:”Auto (default) enable management module to overwrite hardware switch settings; Switch – Use onboard DIP switches”},{“name”:”Universal AC/DC adapter”,”normalizedValue”:”100-240v AC, regulated DC adapter included”,”value”:”100-240v AC, regulated DC adapter included”},{“name”:”Management console port”,”normalizedValue”:”RS232 Serial RJ45 – Cisco pinout for use with standard CAT5 \”rolled cable\” (crossover) 9600 to 115k bps 7/8 bits Odd,even, no parity 1/2 stop bits Hardware/software flow control DCD/DSR monitoring”,”value”:”RS232 Serial RJ45 – Cisco pinout for use with standard CAT5 \”rolled cable\” (crossover) 9600 to 115k bps 7/8 bits Odd,even, no parity 1/2 stop bits Hardware/software flow control DCD/DSR monitoring”},{“name”:”Operating Humidity”,”normalizedValue”:”5% to 90% non-condensing”,”value”:”5% to 90% non-condensing”},{“name”:”Power / TST”,”normalizedValue”:”This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink when in Loopback test mode.”,”value”:”This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink when in Loopback test mode.”},{“name”:”Operating Altitude”,”normalizedValue”:”Up to 3,048 meters (10,000 feet)”,”value”:”Up to 3,048 meters (10,000 feet)”},{“name”:”Current”,”normalizedValue”:”0.33amps at12vdc”,”value”:”0.33amps at12vdc”},{“name”:”Electrical Safety”,”normalizedValue”:”UL 60950-1″,”value”:”UL 60950-1″},{“name”:”Reset button”,”normalizedValue”:”Recessed pinhole button resets module”,”value”:”Recessed pinhole button resets module”},{“name”:”Bit Error Rate (BER)”,”normalizedValue”:”\u003c10-12″,”value”:”\u003c10-12″},{“name”:”Storage Humidity”,”normalizedValue”:”5% to 95% non-condensing”,”value”:”5% to 95% non-condensing”},{“name”:”Link Pass Through”,”normalizedValue”:”Enabled (Default)- When the state of the receiver is changed on the 100Base-TX interface it is reflected on the 100Base-FX fiber transmitter. When the state of the receiver on the 100Base-FX interface is changed it is reflected on the 100Base-TX transmitter; When a Far-End Fault Indication is received on the fiber interface the 100Base-TX transmitter is turned off. When the Far-End Fault Indication is cleared the transmitter is turned back on; Disabled- The 100Base-TX and the 100Base-FX fiber interface operate independently. Far-End Fault indication on the 100Base-FX fiber interface has no effect on the 100Base-TX interface.”,”value”:”Enabled (Default)- When the state of the receiver is changed on the 100Base-TX interface it is reflected on the 100Base-FX fiber transmitter. When the state of the receiver on the 100Base-FX interface is changed it is reflected on the 100Base-TX transmitter; When a Far-End Fault Indication is received on the fiber interface the 100Base-TX transmitter is turned off. When the Far-End Fault Indication is cleared the transmitter is turned back on; Disabled- The 100Base-TX and the 100Base-FX fiber interface operate independently. Far-End Fault indication on the 100Base-FX fiber interface has no effect on the 100Base-TX interface.”},{“name”:”Power Consumption”,”normalizedValue”:”3.98watts”,”value”:”3.98watts”},{“name”:”Management ethernet port”,”normalizedValue”:”10/100/1000Base-T – RJ45; Auto- MDI/MDIX”,”value”:”10/100/1000Base-T – RJ45; Auto- MDI/MDIX”},{“name”:”LKC”,”normalizedValue”:”Green indicator indicating an active Ethernet link. Blinking indicates RX and TX of data”,”value”:”Green indicator indicating an active Ethernet link. Blinking indicates RX and TX of data”},{“name”:”Storage temperature”,”normalizedValue”:”minimum range of -25 C to 70 C (-13 F to 158 F)”,”value”:”minimum range of -25 C to 70 C (-13 F to 158 F)”},{“name”:”ALM”,”normalizedValue”:”Red alarm indicator activated when an alert event occurs”,”value”:”Red alarm indicator activated when an alert event occurs”},{“name”:”100/1000″,”normalizedValue”:”Green – 1000 Mbps link; Yellow – 100 Mbps link; Off – 10 Mbps or no Link”,”value”:”Green – 1000 Mbps link; Yellow – 100 Mbps link; Off – 10 Mbps or no Link”},{“name”:”Heat Output ( BTU/HR )”,”normalizedValue”:”13.6″,”value”:”13.6″},{“name”:”Fiber link on / Receive activity (LKF)”,”normalizedValue”:”This green LED is operational only when power is applied; The LED is on when the 100Base-FX link is on and flashes with a 50% duty cycle when data is received.”,”value”:”This green LED is operational only when power is applied; The LED is on when the 100Base-FX link is on and flashes with a 50% duty cycle when data is received.”},{“name”:”Operating temperature”,”normalizedValue”:”0 C to 50 C (32 F to 122 F)”,”value”:”0 C to 50 C (32 F to 122 F)”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Canada”,”value”:”Canada”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.