Smart UPS, 8kVA, Online/Double Conversion, Out: 120/208V AC In: 208V AC

$7282,99

Smart UPS, Online Double Conversion, Power Rating 8 kVA, Wattage 6.4 kW, Input Voltage 208V AC, Output Voltage 120V AC, 208V AC, Backup Time (Half/Full Load) 13.5 min/5.5 min, Mounting Rack/Tower, Outlet Type UPS/Surge, Number of Outlets 18, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration (12) 5-15/20R, (2) L6-30R, (4) L6-20R, NEMA Plug Configuration Hardwire, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 0 msec, Width 18 in, Depth 26 in

Out of stock

SKU: GRG2228427 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”8 kVA”,”rank”:2,”value”:”8.0 kVA”},{“name”:”UPS Type”,”normalizedValue”:”Online, Double Conversion”,”rank”:3,”value”:”Online/Double Conversion”},{“name”:”Watts – UPS Systems”,”normalizedValue”:”6.4 kW”,”rank”:3,”value”:”6.4 kW”},{“name”:”Power Rating”,”normalizedValue”:”8 kVA”,”rank”:4,”value”:”8kVA”},{“name”:”Input Voltage – UPS Systems”,”normalizedValue”:”208V AC”,”rank”:4,”value”:”208V AC”},{“name”:”Output Voltage – UPS Systems”,”normalizedValue”:”120V AC, 208V AC”,”rank”:5,”value”:”120V AC, 208V AC”},{“name”:”Mounting”,”normalizedValue”:”Tower, Rack”,”rank”:5,”value”:”Rack/Tower”},{“name”:”Wattage”,”normalizedValue”:”7.2 kW”,”rank”:6,”value”:”7.2 kW”},{“name”:”Input Voltage”,”normalizedValue”:”208V AC”,”rank”:7,”value”:”208V AC”},{“name”:”Output Voltage”,”normalizedValue”:”120/208V AC”,”rank”:8,”value”:”120/208V AC”},{“name”:”Outlet Type – UPS Systems”,”normalizedValue”:”UPS/Surge”,”rank”:8,”value”:”UPS/Surge”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”13.5 min/5.5 min”,”rank”:9,”value”:”13.5 min/5.5 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”18″,”rank”:12,”value”:”18″},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Transfer Time”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Ports”,”normalizedValue”:”Contact Closure, DB9 Serial, EPO, SNMP/Web Slot, USB (HID Enabled)”,”value”:”Contact Closure, DB9 Serial, EPO, SNMP/Web Slot, USB (HID Enabled)”},{“name”:”Special Features”,”normalizedValue”:”True Online Protection with Pure Sine Wave Output, Use in Economy Mode to Save Operating Costs, Extended Runtime Option with BP240V10RT3U, Hot-Swappable Feature Lets Users Replace/Repair UPS without Powering Down Connected Equipment,”,”value”:”True Online Protection with Pure Sine Wave Output, Use in Economy Mode to Save Operating Costs, Extended Runtime Option with BP240V10RT3U, Hot-Swappable Feature Lets Users Replace/Repair UPS without Powering Down Connected Equipment,”},{“name”:”Cord Length”,”normalizedValue”:”No Cord”,”value”:”No Cord”},{“name”:”Footnotes”,”normalizedValue”:”1,2,3,12″,”value”:”1,2,3,12″},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”Hardwire”,”value”:”Hardwire”},{“name”:”Watts”,”normalizedValue”:”6,400″,”value”:”6.4kW”},{“name”:”Input Current”,”normalizedValue”:”44.2 A”,”value”:”44.2 A”},{“name”:”Mounting – UPS Systems”,”normalizedValue”:”Rack, Tower”,”value”:”Rack/Tower”},{“name”:”Height”,”normalizedValue”:”5 in”,”value”:”5 in”},{“name”:”Includes”,”normalizedValue”:”(4) Post Compatible Rack Rail Kit, BP240V10RT3U External Battery Pack, SU5000XFMRT2U Step Down Transformer, SUPDMB710 Detachable PDU with Manual Bypass Switch, Tower Stands for Upright Tower Configuration, USB, DB9 and EPO Cabling”,”value”:”(4) Post Compatible Rack Rail Kit, BP240V10RT3U External Battery Pack, SU5000XFMRT2U Step Down Transformer, SUPDMB710 Detachable PDU with Manual Bypass Switch, Tower Stands for Upright Tower Configuration, USB, DB9 and EPO Cabling”},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), FCC Part 15 Class a (USA), IEC 61000, NOM (Mexico), RoHS, UL1778″,”value”:”CSA (Canada), FCC Part 15 Class a (USA), IEC 61000, NOM (Mexico), RoHS, UL1778″},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Width”,”normalizedValue”:”18 in”,”value”:”18 in”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Depth”,”normalizedValue”:”26 in”,”value”:”26 in”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L6-30R, L6-20R, 5-15/20R”,”value”:”(12) 5-15/20R, (2) L6-30R, (4) L6-20R”},{“name”:”Voltage”,”normalizedValue”:”120/208″,”value”:”120/208″},{“name”:”Overall Width”,”normalizedValue”:”17.52 in”,”value”:”17.52 in”},{“name”:”Overall Height”,”normalizedValue”:”5.16 in”,”value”:”5.16 in”},{“name”:”Capacity – Batteries”,”normalizedValue”:”8000 VA”,”value”:”8000 VA”},{“name”:”Backup/Run Time (Full Load)”,”normalizedValue”:”5.50 Minute/13.50 Minute”,”value”:”5.50 Minute/13.50 Minute”},{“name”:”Input Connection”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”Battery Type”,”normalizedValue”:”Lead Acid”,”value”:”Valve Regulated Lead Acid (VRLA)”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.96″,”value”:”0.96″},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output frequency regulation +/- 0.05Hz (free running)”,”value”:”Output frequency regulation +/- 0.05Hz (free running)”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Corrects overvoltages up to 300V”,”value”:”Corrects overvoltages up to 300V”},{“name”:”Output Isolation Transformer”,”normalizedValue”:”120V output is isolation transformer protected”,”value”:”120V output is isolation transformer protected”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Supports extended runtime with optional external battery packs”,”value”:”Supports extended runtime with optional external battery packs”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP240V10RT3U ; BP240V787C-1PH”,”value”:”BP240V10RT3U ; BP240V787C-1PH”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”131″,”value”:”131″},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”120 V, 208 V”,”value”:”120V; 208V”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports”,”value”:”Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)”,”value”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Alarm cancel switch”,”value”:”Alarm cancel switch”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.91″,”value”:”0.91″},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”100V”,”value”:”100V”},{“name”:”Maximum Device Depth (in.)”,”normalizedValue”:”32.5″,”value”:”32.5″},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”208 V AC”,”value”:”208V AC”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”2% output voltage regulation in standard online, double-conversion mode”,”value”:”2% output voltage regulation in standard online, double-conversion mode”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”13 min 30 sec”,”value”:”13.5 min. (3600w)”},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”445″,”value”:”445″},{“name”:”Audible Alarm”,”normalizedValue”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”,”value”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”},{“name”:”Nominal Voltage Details”,”normalizedValue”:”7200 watts total output supported; 5000 watts maximum 120V output; Add 1 additional SU5000XFMRT2U transformer for full load 120V operation; Voltage selection via front panel LCD interface; This configuration requires the Power Module be set to 208V output voltage; Included step-down transformer supports 120V output”,”value”:”7200 watts total output supported; 5000 watts maximum 120V output; Add 1 additional SU5000XFMRT2U transformer for full load 120V operation; Voltage selection via front panel LCD interface; This configuration requires the Power Module be set to 208V output voltage; Included step-down transformer supports 120V output”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”7,200″,”value”:”7200″},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITHD )”,”value”:”2 post rackmount ( 2POSTRMKITHD )”},{“name”:”Stepdown Transformer Dimensions (hwd / in.)”,”normalizedValue”:”3.5 x 17.5 x 20.8″,”value”:”3.5 x 17.5 x 20.8″},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,024″,”value”:”1024″},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Rack Height”,”normalizedValue”:”8 U”,”value”:”8U”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”,”value”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”2,432″,”value”:”2432″},{“name”:”Frequency Compatibility”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”44.2 A”,”value”:”44.2A (208V)”},{“name”:”Transfer Time (Economy Mode)”,”normalizedValue”:”8 ms. typical power failure response in optional economy mode”,”value”:”8 ms. typical power failure response in optional economy mode”},{“name”:”UPS Certification Details”,”normalizedValue”:”IEC 61000-4-5 1995 B Surge Immunity”,”value”:”IEC 61000-4-5 1995 B Surge Immunity”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”LED Indicators”,”normalizedValue”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”,”value”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”2,565″,”value”:”2565″},{“name”:”Operating Elevation (m)”,”normalizedValue”:”0-3000 m”,”value”:”0-3000 m”},{“name”:”UPS Dimensions Details”,”normalizedValue”:”Includes 3U UPS/power module, 3U battery pack, 2U SU5000XFMRT2U step down transformer plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”,”value”:”Includes 3U UPS/power module, 3U battery pack, 2U SU5000XFMRT2U step down transformer plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”8″,”value”:”8″},{“name”:”Audible Noise”,”normalizedValue”:”60 dBA at front side 1 meter”,”value”:”60 dBA at front side 1 meter”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”240″,”value”:”240″},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 6 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 6 hours from 10% to 90% (typical, full load discharge)”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”2,732″,”value”:”2732″},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”50A”,”value”:”50A”},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD”},{“name”:”Output Receptacles”,”normalizedValue”:”5-15/20R, L6-30R, L6-20R”,”value”:”(12) 5-15/20R; (4) L6-20R; (2) L6-30R”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Output Circuit Breakers”,”normalizedValue”:”20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlets each, 20A single-pole (x4) protect 3 5-15/20R outlets each”,”value”:”20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlets each, 20A single-pole (x4) protect 3 5-15/20R outlets each”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”656″,”value”:”656″},{“name”:”Power Factor”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable external battery packs”,”value”:”Hot-swappable, user replaceable external battery packs”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Communications Cable”,”normalizedValue”:”USB, DB9 serial and EPO cables included”,”value”:”USB, DB9 serial and EPO cables included”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Corrects undervoltages as low as 100V”,”value”:”Corrects undervoltages as low as 100V”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”UPS Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Output Capacity Details”,”normalizedValue”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less”,”value”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less”},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”37.5″,”value”:”37.5″},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”300V”,”value”:”300V”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”5 min 30 sec”,”value”:”5.5 min. (7200w)”},{“name”:”Economy Mode Operation”,”normalizedValue”:”Optional economy mode enables high-efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.”,”value”:”Optional economy mode enables high-efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.”},{“name”:”UPS Input Connection Description”,”normalizedValue”:”3 wire single phase input (L1, L2, G)”,”value”:”3 wire single phase input (L1, L2, G)”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”3 sets of adjustable 4 post rack rails included; 2-9USTAND tower kit included”,”value”:”3 sets of adjustable 4 post rack rails included; 2-9USTAND tower kit included”},{“name”:”UPS Input Connection Type”,”normalizedValue”:”Hardwire”,”value”:”Hardwire”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”7.2″,”value”:”7.2″},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”8,000″,”value”:”8000″},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”0-3000m (0 to 10,000 ft.)”,”value”:”0-3000m (0 to 10,000 ft.)”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”5.14 x 17.5 x 25.82″,”value”:”5.14 x 17.5 x 25.82″},{“name”:”Bypass Switch”,”normalizedValue”:”Manual”,”value”:”Manual”},{“name”:”Product Name”,”normalizedValue”:”SmartOnline SU8000RT3U1TF 8kVA Tower/Rack Mountable UPS”,”value”:”SmartOnline SU8000RT3U1TF 8kVA Tower/Rack Mountable UPS”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert UPS Monitoring Software”,”value”:”PowerAlert UPS Monitoring Software”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Receptacle Detail”,”normalizedValue”:”4 x NEMA L6-20R, 12 x NEMA 5-15/20R, 2 x NEMA L6-30R”,”value”:”4 x NEMA L6-20R, 12 x NEMA 5-15/20R, 2 x NEMA L6-30R”},{“name”:”Load Capacity”,”normalizedValue”:”8000 VA”,”value”:”8000 VA”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”8 hr”,”value”:”8 Hour”},{“name”:”Backup/Run Time (Half Load)”,”normalizedValue”:”13 min 30 sec”,”value”:”13.50 Minute”},{“name”:”Product Line”,”normalizedValue”:”SmartOnline”,”value”:”SmartOnline”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Additional Information”,”normalizedValue”:”Supports detailed monitoring of equipment load levels, self-test data and mains power conditions via network interfaces. Includes PowerAlert monitoring software and complete cabling, Network-grade AC surge and noise suppression, Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output”,”value”:”Supports detailed monitoring of equipment load levels, self-test data and mains power conditions via network interfaces. Includes PowerAlert monitoring software and complete cabling, Network-grade AC surge and noise suppression, Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output”},{“name”:”Product Type”,”normalizedValue”:”Double Conversion Online UPS”,”value”:”Double Conversion Online UPS”},{“name”:”Package Contents”,”normalizedValue”:”SmartOnline SU8000RT3U1TF 8kVA Tower/Rack Mountable UPS, 3U power module with detachable hot-swap PDU input/output panel and bypass switch, 3U external battery pack, 2U step-down transformer, Three sets of 4 post rackmount rails (one for each of the 2U and 3U components), One set of”,”value”:”SmartOnline SU8000RT3U1TF 8kVA Tower/Rack Mountable UPS, 3U power module with detachable hot-swap PDU input/output panel and bypass switch, 3U external battery pack, 2U step-down transformer, Three sets of 4 post rackmount rails (one for each of the 2U and 3U components), One set of”},{“name”:”Input Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Plug/Connector Type”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”UPS Applications”,”normalizedValue”:”Mission Critical Applications”,”value”:”Mission Critical Applications”},{“name”:”Runtime Full Load (min.)”,”normalizedValue”:”5 min 30 sec”,”value”:”5.5 min. (7200W)”},{“name”:”Runtime Half Load (min.)”,”normalizedValue”:”13 min 30 sec”,”value”:”13.5 min. (3600W)”},{“name”:”Battery Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”2,432″,”value”:”2432″},{“name”:”Unit Dimension Details”,”normalizedValue”:”Includes 3U UPS/power module, 3U battery pack, 2U SU5000XFMRT2U step down transformer plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”,”value”:”Includes 3U UPS/power module, 3U battery pack, 2U SU5000XFMRT2U step down transformer plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Package Includes”,”normalizedValue”:”SU8000RT3UPM 3U UPS power module;BP240V10RT3U external battery pack;SU5000XFMRT2U step down transformer;SUPDMB710 Detachable PDU with manual bypass switch;Four post compatible rack rail kit (3 sets);Tower stands for upright tower configuration;USB, DB9 and EPO cabling”,”value”:”SU8000RT3UPM 3U UPS power module;BP240V10RT3U external battery pack;SU5000XFMRT2U step down transformer;SUPDMB710 Detachable PDU with manual bypass switch;Four post compatible rack rail kit (3 sets);Tower stands for upright tower configuration;USB, DB9 and EPO cabling”},{“name”:”Online Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”2,732″,”value”:”2732″},{“name”:”Output Capacity (VA)”,”normalizedValue”:”8,000″,”value”:”8000″},{“name”:”Product Certifications”,”normalizedValue”:”IEC 61000; CSA (Canada); NOM (Mexico); UL 1778″,”value”:”IEC 61000; CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”7,200″,”value”:”7200″},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class A (USA)”,”value”:”FCC Part 15 Class A (USA)”},{“name”:”Transfer Time – Maximum”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Plug Configuration”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-20R, L6-30R, L6-20R”,”value”:”5-20R, L6-20R, L6-30R”},{“name”:”Power Rating – Real”,”normalizedValue”:”7.2 kW”,”value”:”7.2 kW”},{“name”:”Power Cord Length”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP240V10RT3U, BP240V787C-1PH”,”value”:”BP240V10RT3U, BP240V787C-1PH”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Battery Recharge Time”,”normalizedValue”:”6 hr”,”value”:”6 hr”},{“name”:”Run Time – Full Load”,”normalizedValue”:”5 min 30 sec”,”value”:”5.5 min”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”2,565 J”,”value”:”2,565 J”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”18″,”value”:”18″},{“name”:”Number of Outlets – UPS”,”normalizedValue”:”18″,”value”:”18″},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Run Time – Half Load”,”normalizedValue”:”13 min 30 sec”,”value”:”13.5 min”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, SNMP, USB”,”value”:”DB9 Serial, EPO, SNMP, USB”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Overall Depth”,”normalizedValue”:”25.83 in”,”value”:”25.83 in”},{“name”:”Input Current – Maximum”,”normalizedValue”:”44.2 A”,”value”:”44.2 A”},{“name”:”Power Rating – Apparent”,”normalizedValue”:”8 kVA”,”value”:”8 kVA”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Smart UPS, 8kVA, Online/Double Conversion, Out: 120/208V AC In: 208V AC”