Smart UPS, 8kVA, Online/Double Conversion, Out: 120/208V AC In: 208V AC

$7560,99

Smart UPS, Online Double Conversion, Power Rating 8 kVA, Wattage 6.4 kW, Input Voltage 208V AC, Output Voltage 120V AC, 208V AC, Backup Time (Half/Full Load) 13.5 min/5.5 min, Mounting Rack/Tower, Outlet Type UPS/Surge, Number of Outlets 18, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration 5-20R, L6-20R, L6-30R, NEMA Plug Configuration 50A (CS8265C), Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 0 msec, Width 18 in, Depth 26 in, Height 5 in

Out of stock

SKU: GRG2172646 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”8 kVA”,”rank”:2,”value”:”8.0 kVA”},{“name”:”UPS Type”,”normalizedValue”:”Online, Double Conversion”,”rank”:3,”value”:”Online/Double Conversion”},{“name”:”Power Rating”,”normalizedValue”:”8 kVA”,”rank”:4,”value”:”8kVA”},{“name”:”Mounting”,”normalizedValue”:”Tower, Rack”,”rank”:5,”value”:”Rack/Tower”},{“name”:”Wattage”,”normalizedValue”:”7.2 kW”,”rank”:6,”value”:”7.2 kW”},{“name”:”Input Voltage”,”normalizedValue”:”208V AC”,”rank”:7,”value”:”208V AC”},{“name”:”Output Voltage”,”normalizedValue”:”120/208V AC”,”rank”:8,”value”:”120/208V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”13.5 min/5.5 min”,”rank”:9,”value”:”13.5 min/5.5 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”18″,”rank”:12,”value”:”18″},{“name”:”Input Current”,”normalizedValue”:”44.2 A”,”value”:”44.2 A”},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), FCC Part 15 Class a (USA), IEC 61000, NOM (Mexico), RoHS, UL1778″,”value”:”CSA (Canada), FCC Part 15 Class a (USA), IEC 61000, NOM (Mexico), RoHS, UL1778″},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Ports”,”normalizedValue”:”Contact Closure, DB9 Serial, EPO, SNMP/Web Slot, USB (HID Enabled)”,”value”:”Contact Closure, DB9 Serial, EPO, SNMP/Web Slot, USB (HID Enabled)”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Special Features”,”normalizedValue”:”True Online Protection with Pure Sine Wave Output, Extended Runtime Option with BP240V10RT3U, BP240V557C-1PH, BP240V787C-1PH, BP240V1037C-1PH, BP240V1407C-1PH, Hot-Swappable Feature Lets User Replace/Repair UPS without Powering Down Connected Equipment, Use in Economy-Mode Saves Operating Costs,”,”value”:”True Online Protection with Pure Sine Wave Output, Extended Runtime Option with BP240V10RT3U, BP240V557C-1PH, BP240V787C-1PH, BP240V1037C-1PH, BP240V1407C-1PH, Hot-Swappable Feature Lets User Replace/Repair UPS without Powering Down Connected Equipment, Use in Economy-Mode Saves Operating Costs,”},{“name”:”Height”,”normalizedValue”:”5 in”,”value”:”5 in”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Width”,”normalizedValue”:”26 in”,”value”:”26 in”},{“name”:”Includes”,”normalizedValue”:”(4) Post Compatible Rack Rail Kit, BP240V10RT3U External Battery Pack, SU5000XFMRT2U Step Down Transformer, SUPDMB710 Detachable PDU with Manual Bypass Switch, Tower Stands, USB, DB9 and EPO Cabling”,”value”:”(4) Post Compatible Rack Rail Kit, BP240V10RT3U External Battery Pack, SU5000XFMRT2U Step Down Transformer, SUPDMB710 Detachable PDU with Manual Bypass Switch, Tower Stands, USB, DB9 and EPO Cabling”},{“name”:”Transfer Time”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Footnotes”,”normalizedValue”:”1,2,3,12,20″,”value”:”1,2,3,12,20″},{“name”:”Depth”,”normalizedValue”:”26 in”,”value”:”26 in”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L6-30R, L6-20R, 5-15/20R”,”value”:”(12) 5-15/20R; (4) L6-20R; (2) L6-30R”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”50A”,”value”:”50A (CS8265C)”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Overall Height”,”normalizedValue”:”5.16 in”,”value”:”5.16 in”},{“name”:”Overall Width”,”normalizedValue”:”17.52 in”,”value”:”17.52 in”},{“name”:”Voltage”,”normalizedValue”:”120/208″,”value”:”120/208″},{“name”:”Input Connection”,”normalizedValue”:”10 ft Cord with Hubbell CS8265 Plug”,”value”:”10 ft Cord with Hubbell CS8265 Plug”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Operating Elevation (m)”,”normalizedValue”:”0-3000 m”,”value”:”0-3000 m”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”240″,”value”:”240″},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”208 V AC”,”value”:”208V AC”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”13 min 30 sec”,”value”:”13.5 min. (3600w)”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.91″,”value”:”0.91″},{“name”:”Undervoltage Correction”,”normalizedValue”:”Corrects undervoltages as low as 100V”,”value”:”Corrects undervoltages as low as 100V”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”100V”,”value”:”100V”},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.96″,”value”:”0.96″},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Supports extended runtime with optional external battery packs”,”value”:”Supports extended runtime with optional external battery packs”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports”,”value”:”Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”2,732″,”value”:”2732″},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Rack Height”,”normalizedValue”:”8 U”,”value”:”8U”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP240V10RT3U ; BP240V787C-1PH”,”value”:”BP240V10RT3U ; BP240V787C-1PH”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”UPS Dimensions Details”,”normalizedValue”:”Includes 3U UPS/power module, 3U battery pack, 2U SU5000XFMRT2U step down transformer plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”,”value”:”Includes 3U UPS/power module, 3U battery pack, 2U SU5000XFMRT2U step down transformer plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”},{“name”:”Output Isolation Transformer”,”normalizedValue”:”120V output is isolation transformer protected”,”value”:”120V output is isolation transformer protected”},{“name”:”Output Circuit Breakers”,”normalizedValue”:”20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlets each, 20A single-pole (x4) protect 3 5-15/20R outlets each”,”value”:”20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlets each, 20A single-pole (x4) protect 3 5-15/20R outlets each”},{“name”:”Maximum Device Depth (in.)”,”normalizedValue”:”32.5″,”value”:”32.5″},{“name”:”Audible Alarm”,”normalizedValue”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”,”value”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”},{“name”:”Transfer Time (Economy Mode)”,”normalizedValue”:”8 ms. typical power failure response in optional economy mode”,”value”:”8 ms. typical power failure response in optional economy mode”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”656″,”value”:”656″},{“name”:”Power Factor”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Communications Cable”,”normalizedValue”:”USB, DB9 serial and EPO cables included”,”value”:”USB, DB9 serial and EPO cables included”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 6 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 6 hours from 10% to 90% (typical, full load discharge)”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”131″,”value”:”131″},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”7.2″,”value”:”7.2″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”LED Indicators”,”normalizedValue”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”,”value”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”0-3000m (0 to 10,000 ft.)”,”value”:”0-3000m (0 to 10,000 ft.)”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”7,200″,”value”:”7200″},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Economy Mode Operation”,”normalizedValue”:”Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.”,”value”:”Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”UPS Certification Details”,”normalizedValue”:”IEC 61000-4-5 1995 B Surge Immunity”,”value”:”IEC 61000-4-5 1995 B Surge Immunity”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”8,000″,”value”:”8000″},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable external battery packs”,”value”:”Hot-swappable, user replaceable external battery packs”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)”,”value”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITHD )”,”value”:”2 post rackmount ( 2POSTRMKITHD )”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Corrects overvoltages up to 300V”,”value”:”Corrects overvoltages up to 300V”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”5 min 30 sec”,”value”:”5.5 min. (7200w)”},{“name”:”Audible Noise”,”normalizedValue”:”60 dBA at front side 1 meter”,”value”:”60 dBA at front side 1 meter”},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,024″,”value”:”1024″},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”37.5″,”value”:”37.5″},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output frequency regulation +/- 0.05Hz (free running)”,”value”:”Output frequency regulation +/- 0.05Hz (free running)”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Alarm cancel switch”,”value”:”Alarm cancel switch”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”2,565″,”value”:”2565″},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”8″,”value”:”8″},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UPS Input Connection Description”,”normalizedValue”:”3 wire single phase input (L1, L2, G)”,”value”:”3 wire single phase input (L1, L2, G)”},{“name”:”Output Capacity Details”,”normalizedValue”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less”,”value”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”44.2 A”,”value”:”44.2A (208V)”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”2% output voltage regulation in standard online, double-conversion mode”,”value”:”2% output voltage regulation in standard online, double-conversion mode”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”208V 50A”,”value”:”208V 50A”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”5.14 x 17.5 x 25.82″,”value”:”5.14 x 17.5 x 25.82″},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”120 V, 208 V”,”value”:”120V; 208V”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”3 sets of adjustable 4 post rack rails included (for separate UPS, transformer and battery pack components); 2-9USTAND tower kit included (supports up to 9U in tower format)”,”value”:”3 sets of adjustable 4 post rack rails included (for separate UPS, transformer and battery pack components); 2-9USTAND tower kit included (supports up to 9U in tower format)”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”300V”,”value”:”300V”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”,”value”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”2,432″,”value”:”2432″},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Load Capacity”,”normalizedValue”:”8000 VA”,”value”:”8000 VA”},{“name”:”Additional Information”,”normalizedValue”:”Ideal for protection of sensitive electronics in any application calling for upright tower or 19 inch rackmount UPS protection, Common applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems”,”value”:”Ideal for protection of sensitive electronics in any application calling for upright tower or 19 inch rackmount UPS protection, Common applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems”},{“name”:”Package Contents”,”normalizedValue”:”SU8000RT3UPM 3U UPS Power Module, BP240V10RT3U External Battery Pack, SU5000XFMRT2U Step Down Transformer, SUPDMB710 Detachable PDU with manual bypass switch, Four post compatible rack rail kit (3 sets), Tower stands for upright tower configuration, PowerAlert software, complete data cabling and user manual”,”value”:”SU8000RT3UPM 3U UPS Power Module, BP240V10RT3U External Battery Pack, SU5000XFMRT2U Step Down Transformer, SUPDMB710 Detachable PDU with manual bypass switch, Four post compatible rack rail kit (3 sets), Tower stands for upright tower configuration, PowerAlert software, complete data cabling and user manual”},{“name”:”Package Includes”,”normalizedValue”:”SU8000RT3UPM 3U UPS power module;BP240V10RT3U external battery pack;SU5000XFMRT2U step down transformer;SUPDMB710 Detachable PDU with manual bypass switch;Four post compatible rack rail kit (3 sets);Tower stands for upright tower configuration;USB, DB9 and EPO cabling”,”value”:”SU8000RT3UPM 3U UPS power module;BP240V10RT3U external battery pack;SU5000XFMRT2U step down transformer;SUPDMB710 Detachable PDU with manual bypass switch;Four post compatible rack rail kit (3 sets);Tower stands for upright tower configuration;USB, DB9 and EPO cabling”},{“name”:”Product Certifications”,”normalizedValue”:”IEC 61000; CSA (Canada); NOM (Mexico); UL 1778″,”value”:”IEC 61000; CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class A (USA)”,”value”:”FCC Part 15 Class A (USA)”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”8,000″,”value”:”8000″},{“name”:”UPS Applications”,”normalizedValue”:”Mission Critical Applications”,”value”:”Mission Critical Applications”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”7,200″,”value”:”7200″},{“name”:”Unit Dimension Details”,”normalizedValue”:”Includes 3U UPS/power module, 3U battery pack, 2U SU5000XFMRT2U step down transformer plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”,”value”:”Includes 3U UPS/power module, 3U battery pack, 2U SU5000XFMRT2U step down transformer plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”18″,”value”:”18″},{“name”:”Battery Recharge Time”,”normalizedValue”:”6 hr”,”value”:”6 hr”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Power Rating – Real”,”normalizedValue”:”6.4 kW”,”value”:”6.4 kW”},{“name”:”Input Current – Maximum”,”normalizedValue”:”44.2 A”,”value”:”44.2 A”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, SNMP, USB”,”value”:”DB9 Serial, EPO, SNMP, USB”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP240V10RT3U, BP240V787C-1PH”,”value”:”BP240V10RT3U, BP240V787C-1PH”},{“name”:”Overall Depth”,”normalizedValue”:”25.83 in”,”value”:”25.83 in”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-20R, L6-30R, L6-20R”,”value”:”5-20R, L6-20R, L6-30R”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”2,565 J”,”value”:”2,565 J”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Smart UPS, 8kVA, Online/Double Conversion, Out: 120/208V AC In: 208V AC”