Description
[{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”UPS Type”,”normalizedValue”:”Online”,”rank”:3,”value”:”Online”},{“name”:”Power Rating”,”normalizedValue”:”5 kVA”,”rank”:4,”value”:”5kVA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”4.5 kW”,”rank”:6,”value”:”4.5 kW”},{“name”:”Input Voltage”,”normalizedValue”:”208V AC”,”rank”:7,”value”:”208V AC”},{“name”:”Output Voltage”,”normalizedValue”:”120/208V”,”rank”:8,”value”:”120/208V”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”11 min/3.5 min”,”rank”:9,”value”:”11 min/3.5 min”},{“name”:”Number of Outlets”,”normalizedValue”:”16″,”rank”:12,”value”:”16″},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”L5-30P”,”value”:”L5-30P”},{“name”:”Transfer Time”,”normalizedValue”:”No transfer time (0 ms.) in online, double-conversion mode”,”value”:”No transfer time (0 ms.) in online, double-conversion mode”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L6-30R, L6-20R, 5-15/20R”,”value”:”(12) 5-15/20R; (2) L6-20R; (2) L6-30R”},{“name”:”Width”,”normalizedValue”:”20.67 in”,”value”:”20.67 in”},{“name”:”Housing Material”,”normalizedValue”:”Sheet metal”,”value”:”Sheet metal”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”156V (full load) / 100V (50% load or less, derates linearly)”,”value”:”156V (full load) / 100V (50% load or less, derates linearly)”},{“name”:”LED Indicators”,”normalizedValue”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”,”value”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Operating Temperature Range”,”normalizedValue”:”32° to 104°F (0° to 40°C)”,”value”:”32° to 104°F (0° to 40°C)”},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class B (USA)”,”value”:”FCC Part 15 Class B (USA)”},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”640″,”value”:”640″},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”280V (full load) / 300V (90% load or less)”,”value”:”280V (full load) / 300V (90% load or less)”},{“name”:”UPS Applications”,”normalizedValue”:”Mission Critical Applications”,”value”:”Mission Critical Applications”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”6.85 x 17.5 x 20.67″,”value”:”6.85 x 17.5 x 20.67″},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”192″,”value”:”192″},{“name”:”Power Factor”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”30A”,”value”:”30A”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”174″,”value”:”174″},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”0 to 6560 ft. / 0 to 2000 m”,”value”:”0 to 6560 ft. / 0 to 2000 m”},{“name”:”Battery Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”1,708″,”value”:”1708″},{“name”:”Overvoltage Correction”,”normalizedValue”:”2% output voltage regulation during overvoltages to 280V (full load) / 300V (90% load or less)”,”value”:”2% output voltage regulation during overvoltages to 280V (full load) / 300V (90% load or less)”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Relative Humidity”,”normalizedValue”:”5% to 90% (non-condensing)”,”value”:”5% to 90% (non-condensing)”},{“name”:”Communications Interface”,”normalizedValue”:”DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)”,”value”:”DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )”,”value”:”2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )”},{“name”:”Undervoltage Correction”,”normalizedValue”:”2% output voltage regulation during undervoltages to 156V (full load) / 100V (50% load or less)”,”value”:”2% output voltage regulation during undervoltages to 156V (full load) / 100V (50% load or less)”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)”,”value”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”4,500″,”value”:”4500″},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”2 sets of adjustable 4 post rack rails included”,”value”:”2 sets of adjustable 4 post rack rails included”},{“name”:”Storage Temperature Range”,”normalizedValue”:”5° to 122°F”,”value”:”5° to 122°F (-15° to 50°C)”},{“name”:”Minimum Required Rack Depth with External Battery Pack (in.)”,”normalizedValue”:”29″,”value”:”29″},{“name”:”Output Circuit Breakers”,”normalizedValue”:”High voltage 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered; Low voltage 20A breakers protect 3 5-15/20R outlets each”,”value”:”High voltage 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered; Low voltage 20A breakers protect 3 5-15/20R outlets each”},{“name”:”Battery Access”,”normalizedValue”:”Front panel battery access door”,”value”:”Front panel battery access door”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Online, double-conversion power conditioning”,”value”:”Online, double-conversion power conditioning”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”120 V, 208 V”,”value”:”120V; 208V”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”5,000″,”value”:”5000″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,767″,”value”:”1767″},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output frequency regulation +/- 0.05Hz (free running)”,”value”:”Output frequency regulation +/- 0.05Hz (free running)”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP192V12-3U ; BP192V5RT2U (limit 1); BP192V787C-1PH”,”value”:”BP192V12-3U ; BP192V5RT2U (limit 1); BP192V787C-1PH”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Two contact closure monitoring options available – RELAYIOCARD with six configurable contact closure outputs (uses UPS card slot) and RELAYIOMINI with 3 configurable contact closure outputs (requires removal of USB port module)”,”value”:”Two contact closure monitoring options available – RELAYIOCARD with six configurable contact closure outputs (uses UPS card slot) and RELAYIOMINI with 3 configurable contact closure outputs (requires removal of USB port module)”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”208 V AC”,”value”:”208V AC”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”525″,”value”:”525″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Network Management Cards”,”normalizedValue”:”TLNETCARD, RELAYIOCARD, MODBUSCARD, WEBCARDLXE”,”value”:”TLNETCARD ; WEBCARDLXE ; MODBUSCARD ; RELAYIOCARD”},{“name”:”Unit Dimensions (hwd / in.)”,”normalizedValue”:”10.05 x 17.5 x 20.75″,”value”:”10.050 x 17.500 x 20.750″},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”24 A”,”value”:”24A (208V)”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”2,595″,”value”:”2595″},{“name”:”Package Includes”,”normalizedValue”:”SU5000RT4UHV UPS Power Module;SU5000XFMRT2U Stepdown Transformer;4 Post Rackmount Installation Rails;USB, DB9 and EPO cables”,”value”:”SU5000RT4UHV UPS Power Module;SU5000XFMRT2U Stepdown Transformer;4 Post Rackmount Installation Rails;USB, DB9 and EPO cables”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Product Certifications”,”normalizedValue”:”IEC 61000; CSA (Canada); UL 1778″,”value”:”IEC 61000; CSA (Canada); UL 1778″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Auto Probe Monitoring (requires WEBCARDLXE); Automatic inverter bypass; Hot swappable batteries; Remote management; Surge/noise protection; Zero transfer time”,”value”:”Auto Probe Monitoring (requires WEBCARDLXE); Automatic inverter bypass; Hot swappable batteries; Remote management; Surge/noise protection; Zero transfer time”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions”},{“name”:”Audible Alarm”,”normalizedValue”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”,”value”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”},{“name”:”Communications Cable”,”normalizedValue”:”USB, DB9 serial and EPO cables included”,”value”:”USB, DB9 serial and EPO cables included”},{“name”:”Output Capacity Details”,”normalizedValue”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared”,”value”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared”},{“name”:”Maximum Device Depth (in.)”,”normalizedValue”:”20.75″,”value”:”20.75″},{“name”:”Minimum Required Rack Depth without External Battery Pack (in.)”,”normalizedValue”:”25.75″,”value”:”25.75″},{“name”:”Rack Height”,”normalizedValue”:”6 U”,”value”:”6U”},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Online Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”1,767″,”value”:”1767″},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Audible Noise”,”normalizedValue”:”65 dB at 1m front side”,”value”:”65 dB at 1m front side”},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.96″,”value”:”0.96″},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Alarm cancel switch”,”value”:”Alarm cancel switch”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”6 hours from 10% to 90% (typical, full load discharge)”,”value”:”6 hours from 10% to 90% (typical, full load discharge)”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC5-192 (qty 1)”,”value”:”RBC5-192 (qty 1)”},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.