Description
[{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”500 VA”,”rank”:2,”value”:”500.0 VA”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”500 VA”,”rank”:4,”value”:”500VA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”300 W”,”rank”:6,”value”:”300 W”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”120V AC”,”rank”:8,”value”:”120V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”14 min/3 min”,”rank”:9,”value”:”14 min/3 min”},{“name”:”Outlet Type”,”normalizedValue”:”(1) Surge; (6) UPS/Surge”,”rank”:10,”value”:”(1) Surge; (6) UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”6″,”rank”:12,”value”:”6″},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Special Features”,”normalizedValue”:”Advanced AVR Corrects Brownouts and Overvoltages, Pure Sine Wave Output”,”value”:”Advanced AVR Corrects Brownouts and Overvoltages, Pure Sine Wave Output”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Height”,”normalizedValue”:”2 in”,”value”:”2 in”},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), ENERGY STAR Qualified, FCC Part 15 Class B (USA), ICES (Canada), NOM (Mexico), RoHS, UL1778″,”value”:”CSA (Canada), ENERGY STAR Qualified, FCC Part 15 Class B (USA), ICES (Canada), NOM (Mexico), RoHS, UL1778″},{“name”:”Display Type”,”normalizedValue”:”LED”,”value”:”LED”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(6) 5-15R”},{“name”:”Footnotes”,”normalizedValue”:”3,4,10,12″,”value”:”3,4,10,12″},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Input Current”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, SNMP/Web Slot, USB (HID Enabled)”,”value”:”DB9 Serial, EPO, SNMP/Web Slot, USB (HID Enabled)”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Depth”,”normalizedValue”:”12 in”,”value”:”12 in”},{“name”:”Transfer Time”,”normalizedValue”:”4 to 6 msec”,”value”:”4 to 6 msec”},{“name”:”Includes”,”normalizedValue”:”Cables for USB and DB9 Monitoring and EPO Switching, Mounting Hardware, PowerAlert Unattended Shutdown and UPS/Power Monitoring Software”,”value”:”Cables for USB and DB9 Monitoring and EPO Switching, Mounting Hardware, PowerAlert Unattended Shutdown and UPS/Power Monitoring Software”},{“name”:”Width”,”normalizedValue”:”12 in”,”value”:”12 in”},{“name”:”Overall Width”,”normalizedValue”:”17.32 in”,”value”:”17.32 in”},{“name”:”Overall Height”,”normalizedValue”:”1.73 in”,”value”:”1.73 in”},{“name”:”Voltage”,”normalizedValue”:”120″,”value”:”120″},{“name”:”Capacity – Batteries”,”normalizedValue”:”500 VA/300 W”,”value”:”500 VA/300 W”},{“name”:”Battery Type”,”normalizedValue”:”Sealed Lead Acid”,”value”:”Sealed Lead Acid (SLA)”},{“name”:”Housing Color”,”normalizedValue”:”Black”,”value”:”Black”},{“name”:”Operating Temp. Range”,”normalizedValue”:”122\u0026deg;F (50\u0026deg;C)”,”value”:”122\u0026deg;F (50\u0026deg;C)”},{“name”:”Input Connection”,”normalizedValue”:”10 ft Cord with NEMA 5-15P Plug”,”value”:”10 ft Cord with NEMA 5-15P Plug”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”AC Suppression Joule Rating”,”normalizedValue”:”567″,”value”:”567″},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”14 min 36 sec”,”value”:”14.6 min. (150w)”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”44″,”value”:”44″},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Grounding Lug”,”normalizedValue”:”Back panel grounding lug”,”value”:”Back panel grounding lug”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”15A”,”value”:”15A”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”500″,”value”:”500″},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”Included mounting brackets provide front-rail installation in 2 or 4 post racks, plus upright tower configurations”,”value”:”Included mounting brackets provide front-rail installation in 2 or 4 post racks, plus upright tower configurations”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 90 and 105 are boosted by 14%”,”value”:”Input voltages between 90 and 105 are boosted by 14%”},{“name”:”Rack Height”,”normalizedValue”:”1 U”,”value”:”1U”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC62-1U”,”value”:”RBC62-1U”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 16 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 16 hours from 10% to 90% (typical, full load discharge)”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”140″,”value”:”140″},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”Audible Noise”,”normalizedValue”:”45 dBA maximum, front side 1m”,”value”:”45 dBA maximum, front side 1m”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico)”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”2 post 19 inch rackmount; 4 post 19 inch rackmount; Tower”,”value”:”2 post 19 inch rackmount; 4 post 19 inch rackmount; Tower”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”90″,”value”:”90″},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”12 A”,”value”:”12A (Maximum input with 300W UPS and 1140W surge-only loads)”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.96″,”value”:”0.96″},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure, overload and low-battery conditions”,”value”:”Audible alarm indicates power-failure, overload and low-battery conditions”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 90″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 90″},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”3 min 12 sec”,”value”:”3.2 min. (300w)”},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 cabling included”,”value”:”USB and DB9 cabling included”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”300″,”value”:”300″},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX”},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”14.26″,”value”:”14.26″},{“name”:”Expandable Runtime”,”normalizedValue”:”No”,”value”:”No”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Network UPS Tools Compatibility”,”normalizedValue”:”NUT compatible. See full list of compatible Tripp Lite products at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”,”value”:”NUT compatible. See full list of compatible Tripp Lite products at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”LED Indicators”,”normalizedValue”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”,”value”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions”,”value”:”Supports detailed monitoring of UPS and site power conditions”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-15%, +13%”,”value”:”-15%, +13%”},{“name”:”Load Management Receptacles”,”normalizedValue”:”One switchable single-outlet 5-15R load bank”,”value”:”One switchable single-outlet 5-15R load bank”},{“name”:”AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”286″,”value”:”286″},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”1.73 x 17.32 x 11.26″,”value”:”1.73 x 17.32 x 11.26″},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”44″,”value”:”44″},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Surge Energy Rating”,”normalizedValue”:”480 J”,”value”:”480 J”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122°F”,”value”:”122°F (50°C)”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Status Indicators”,”normalizedValue”:”5 front panel LEDs – Green POWER LED, 3 color BATTERY CHARGE LED, 3 color OUTPUT LOAD LEVEL LED, red BATTERY WARNING LED.”,”value”:”5 front panel LEDs – Green POWER LED, 3 color BATTERY CHARGE LED, 3 color OUTPUT LOAD LEVEL LED, red BATTERY WARNING LED.”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Waveform Type”,”normalizedValue”:”Pulse-width Modulated Sine Wave”,”value”:”Pulse-width Modulated Sine Wave”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr”,”value”:”4 Hour”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”Load Capacity”,”normalizedValue”:”500 VA/300 W”,”value”:”500 VA/300 W”},{“name”:”Package Contents”,”normalizedValue”:”SMART500RT1U UPS System, Mounting hardware, Cabling for USB \u0026 DB9 monitoring and EPO switching, PowerAlert unattended shutdown and UPS/Power monitoring software, Warranty information and instruction manual”,”value”:”SMART500RT1U UPS System, Mounting hardware, Cabling for USB \u0026 DB9 monitoring and EPO switching, PowerAlert unattended shutdown and UPS/Power monitoring software, Warranty information and instruction manual”},{“name”:”Alarm”,”normalizedValue”:”Low Battery, Overload, UPS Fault, On Battery”,”value”:”Low Battery, Overload, UPS Fault, On Battery”},{“name”:”Total Number of Expansion Slots”,”normalizedValue”:”4″,”value”:”4″},{“name”:”UPS Applications”,”normalizedValue”:”High-End Desktop/Small Network; Retail/Point of Sale; Hospitality”,”value”:”High-End Desktop/Small Network; Retail/Point of Sale; Hospitality”},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”6561 ft. (2000 m) above sea level”,”value”:”6561 ft. (2000 m) above sea level”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.”,”value”:”Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.”},{“name”:”Output Capacity Details”,”normalizedValue”:”4.2A @ 120V. (LINE MODE) 120% @ 5 minutes; (BATTERY MODE) 120% @ 5 seconds”,”value”:”4.2A @ 120V. (LINE MODE) 120% @ 5 minutes; (BATTERY MODE) 120% @ 5 seconds”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”300″,”value”:”300″},{“name”:”Package Includes”,”normalizedValue”:”SMART500RT1U 500VA 300W 120V Line-Interactive UPS;USB cable;DB9 cable;EPO cable;Rack-mounting hardware;Owner’s manual”,”value”:”SMART500RT1U 500VA 300W 120V Line-Interactive UPS;USB cable;DB9 cable;EPO cable;Rack-mounting hardware;Owner’s manual”},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.97″,”value”:”0.97″},{“name”:”Product Compliance”,”normalizedValue”:”ENERGY STAR Qualified”,”value”:”ENERGY STAR Qualified”},{“name”:”Power Factor”,”normalizedValue”:”0.6″,”value”:”0.6″},{“name”:”Grounding Details”,”normalizedValue”:”Back panel grounding lug”,”value”:”Back panel grounding lug”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”500″,”value”:”500″},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); NOM (Mexico); UL 1778″,”value”:”CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Input Current – Maximum”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Overall Depth”,”normalizedValue”:”11.2 in”,”value”:”11.2 in”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Battery Recharge Time”,”normalizedValue”:”12 hr”,”value”:”12 hr”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, SNMP, USB”,”value”:”DB9 Serial, EPO, SNMP, USB”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr, 3 yr (Registration)”,”value”:”2 yr, 3 yr Registration”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”567 J”,”value”:”567 J”},{“name”:”Power Rating – Real”,”normalizedValue”:”300 W”,”value”:”300 W”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Power Outage”,”value”:”Low Battery, Power Outage”},{“name”:”External Battery Compatible”,”normalizedValue”:”Not External Battery Pack Compatible”,”value”:”Not External Battery Pack Compatible”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.