Description
[{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”UPS Type”,”normalizedValue”:”Online”,”rank”:3,”value”:”Online”},{“name”:”Power Rating”,”normalizedValue”:”3,000 VA”,”rank”:4,”value”:”3000VA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”2,700 W”,”rank”:6,”value”:”2700 W”},{“name”:”Input Voltage”,”normalizedValue”:”208V AC”,”rank”:7,”value”:”208V AC”},{“name”:”Output Voltage”,”normalizedValue”:”120/208V”,”rank”:8,”value”:”120/208V”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”13.5 min/5 min”,”rank”:9,”value”:”13.5 min/5 min”},{“name”:”Number of Outlets”,”normalizedValue”:”20″,”rank”:12,”value”:”20″},{“name”:”Transfer Time”,”normalizedValue”:”No transfer time (0 ms.) in online, double-conversion mode; 4 ms. transfer time during economy mode operation”,”value”:”No transfer time (0 ms.) in online, double-conversion mode; 4 ms. transfer time during economy mode operation”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Width”,”normalizedValue”:”24-1/4 in”,”value”:”24.25 in”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”L5-30P”,”value”:”L5-30P”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L6-20R, 5-15/20R; 6-15/20R”,”value”:”(12) 5-15/20R; (6) 6-15/20R; (2) L6-20R”},{“name”:”Housing Material”,”normalizedValue”:”Metal”,”value”:”Metal”},{“name”:”UPS Certifications”,”normalizedValue”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”,”value”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”2,700″,”value”:”2700″},{“name”:”Switches”,”normalizedValue”:”5 front panel switches: On/Off, Up, Down and Escape”,”value”:”5 front panel switches: On/Off, Up, Down and Escape”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”288V”,”value”:”288V”},{“name”:”Relative Humidity”,”normalizedValue”:”5 to 95%, non-condensing”,”value”:”5 to 95%, non-condensing”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”4 post installation accessories included (2 sets)”,”value”:”4 post installation accessories included (2 sets)”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,399″,”value”:”1399″},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 plus assignable contact closure pin functions for On-battery, On bypass, Output-on and Low-battery conditions and remote Shutdown, Output-off, Reboot and Power-toggle operations”,”value”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 plus assignable contact closure pin functions for On-battery, On bypass, Output-on and Low-battery conditions and remote Shutdown, Output-off, Reboot and Power-toggle operations”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, replaceable batteries”,”value”:”Hot-swappable, replaceable batteries”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options”,”value”:”Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”3,000″,”value”:”3000″},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”6.96 x 17.34 x 24.25″,”value”:”6.96 x 17.34 x 24.25″},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power failure, low battery, overload and fault”,”value”:”Audible alarm indicates power failure, low battery, overload and fault”},{“name”:”Rack Height”,”normalizedValue”:”4 U”,”value”:”4U”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Supports extended runtime with optional external battery packs”,”value”:”Supports extended runtime with optional external battery packs”},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 cabling included”,”value”:”USB and DB9 cabling included”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”177″,”value”:”177″},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Undervoltage Correction”,”normalizedValue”:”2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)”,”value”:”2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18 -2US (multi-pack compatible)”,”value”:”BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18 -2US (multi-pack compatible)”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”616″,”value”:”616″},{“name”:”Recommended Electrical Service”,”normalizedValue”:”208V 20A”,”value”:”208V 20A”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Audible Noise”,”normalizedValue”:”\u003c50dB at front side 1M”,”value”:”\u003c50dB at front side 1M”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UPS Certification Details”,”normalizedValue”:”The 3kVA UPS carries agency standards IEC62040-1:2008+A1:2013, UL1778: 2014 R8.15; CAN/CSA-C22.2 No. 107.3-14; CE; EN62040-2:2006, FCC PART 15; NOM; SASO, EAC The 2U step-down transformer carries agency standards UL1778:2014 R10.17 (5TH EDITION); CAN/CSA-C22.2 NO. 107.3-14; CLASS A (emissions); NOM”,”value”:”The 3kVA UPS carries agency standards IEC62040-1:2008+A1:2013, UL1778: 2014 R8.15; CAN/CSA-C22.2 No. 107.3-14; CE; EN62040-2:2006, FCC PART 15; NOM; SASO, EAC The 2U step-down transformer carries agency standards UL1778:2014 R10.17 (5TH EDITION); CAN/CSA-C22.2 NO. 107.3-14; CLASS A (emissions); NOM”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”933″,”value”:”933″},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”\u003e95%”,”value”:”\u003e95%”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”160V (100% load), 140V (66% load), 120V (33% load)”,”value”:”160V (100% load), 140V (66% load), 120V (33% load)”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable batteries”,”value”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable batteries”},{“name”:”LED Indicators”,”normalizedValue”:”4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)”,”value”:”4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD”,”value”:”SNMPWEBCARD ; WEBCARDLX”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITWM ); Tower ( 2-9USTAND )”,”value”:”2 post rackmount ( 2POSTRMKITWM ); Tower ( 2-9USTAND )”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”5 min”,”value”:”5 min. (2700w)”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Online, double-conversion power conditioning”,”value”:”Online, double-conversion power conditioning”},{“name”:”AC Suppression Joule Rating”,”normalizedValue”:”570″,”value”:”570″},{“name”:”AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”72″,”value”:”72″},{“name”:”Minimum Required Rack Depth with External Battery Pack (in.)”,”normalizedValue”:”30.25″,”value”:”30.25″},{“name”:”Output Circuit Breakers”,”normalizedValue”:”Included 2U transformer module includes four 20A 120V circuit breakers (each protects 3 NEMA 5-15/20R outlets).”,”value”:”Included 2U transformer module includes four 20A 120V circuit breakers (each protects 3 NEMA 5-15/20R outlets).”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”14.97 A”,”value”:”14.97A”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Battery Access”,”normalizedValue”:”Front panel battery access door”,”value”:”Front panel battery access door”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”120 V, 208 V”,”value”:”120V; 208V”},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Grounding Lug”,”normalizedValue”:”Back panel grounding lug included”,”value”:”Back panel grounding lug included”},{“name”:”Overvoltage Correction”,”normalizedValue”:”2% output voltage regulation during overvoltages to 288″,”value”:”2% output voltage regulation during overvoltages to 288″},{“name”:”Load Management Receptacles”,”normalizedValue”:”Two switchable outlet load banks (2 NEMA 6-15/20R outlets per bank)”,”value”:”Two switchable outlet load banks (2 NEMA 6-15/20R outlets per bank)”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC72S”,”value”:”RBC72S”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”3.0 hours from 10% to 90% (typical, full load discharge)”,”value”:”3.0 hours from 10% to 90% (typical, full load discharge)”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”13 min 30 sec”,”value”:”13.5 min. (1350w)”},{“name”:”UPS Dataline Suppression Details”,”normalizedValue”:”Single line dialup / network dataline protection included”,”value”:”Single line dialup / network dataline protection included”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”208 V AC”,”value”:”208V AC”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”IMPORTANT! Please ensure the UPS is configured for 60Hz output when used with the included step-down transformer module”,”value”:”IMPORTANT! Please ensure the UPS is configured for 60Hz output when used with the included step-down transformer module”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”2.7″,”value”:”2.7″},{“name”:”Power Factor”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.”},{“name”:”Minimum Required Rack Depth without External Battery Pack (in.)”,”normalizedValue”:”29.25″,”value”:”29.25″},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.”},{“name”:”Output Capacity Details”,”normalizedValue”:”OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and \u003e150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).”,”value”:”OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and \u003e150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”588″,”value”:”588″},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced by following on-screen prompts”,”value”:”Power-fail alarm can be silenced by following on-screen prompts”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”\u003e90%”,”value”:”\u003e90%”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.