Smart UPS, 20kVA, Online, Out: 230/208/200/240/220V AC In: 220V AC

$14209,99

UPS,SmartOnline,20kVA,18kW,Bypass,12U

9999 in stock

SKU: GRG5175801 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”UPS Type”,”normalizedValue”:”Online”,”rank”:3,”value”:”Online”},{“name”:”Power Rating”,”normalizedValue”:”20 kVA”,”rank”:4,”value”:”20kVA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”18 kW”,”rank”:6,”value”:”18 kW”},{“name”:”Input Voltage”,”normalizedValue”:”220V AC”,”rank”:7,”value”:”220V AC”},{“name”:”Output Voltage”,”normalizedValue”:”230/208/200/240/220V AC”,”rank”:8,”value”:”230/208/200/240/220V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”12.50 min/4.30 min”,”rank”:9,”value”:”12.50 min/4.30 min”},{“name”:”Outlet Type”,”normalizedValue”:”Hardwired”,”rank”:10,”value”:”Hardwired”},{“name”:”Number of Outlets”,”normalizedValue”:”10″,”rank”:12,”value”:”10″},{“name”:”Transfer Time”,”normalizedValue”:”No transfer time (0 ms.) in online, double-conversion mode”,”value”:”No transfer time (0 ms.) in online, double-conversion mode”},{“name”:”Height”,”normalizedValue”:”5.1 in”,”value”:”5.1 in”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L6-30R, C19″,”value”:”(2) L6-30R; (8) C19″},{“name”:”Depth”,”normalizedValue”:”26 in”,”value”:”26 in”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Width”,”normalizedValue”:”26 in”,”value”:”26 in”},{“name”:”Input Current”,”normalizedValue”:”112.2 A”,”value”:”112.20 A”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”UPS Input Connection Description”,”normalizedValue”:”3 wire single phase input (L1, L2, G)”,”value”:”3 wire single phase input (L1, L2, G)”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”656″,”value”:”656″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Power Factor”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Undervoltage Correction”,”normalizedValue”:”Corrects undervoltages as low as 100V”,”value”:”Corrects undervoltages as low as 100V”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Applications utilizing any supported network management card option, require the installation of two of the same model network card to install one card per included UPS power module; RELAYIOMINI installation requires removal of panel containing USB ports on each included UPS power module”,”value”:”Applications utilizing any supported network management card option, require the installation of two of the same model network card to install one card per included UPS power module; RELAYIOMINI installation requires removal of panel containing USB ports on each included UPS power module”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”4 sets of adjustable 4 post rack rails included (one for each included 3U module)”,”value”:”4 sets of adjustable 4 post rack rails included (one for each included 3U module)”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”UPS Dimensions Details”,”normalizedValue”:”Includes 2 SU10000RT3UPM UPS/Power modules, 2 BP240V10RT3U Battery packs and SUPDMB20K parallel bypass PDU; Listed weights and dimensions for UPS/Power module and Included battery pack each refer to a single unit; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with parallel bypass PDU installed”,”value”:”Includes 2 SU10000RT3UPM UPS/Power modules, 2 BP240V10RT3U Battery packs and SUPDMB20K parallel bypass PDU; Listed weights and dimensions for UPS/Power module and Included battery pack each refer to a single unit; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with parallel bypass PDU installed”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)”,”value”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)”},{“name”:”Rack Height”,”normalizedValue”:”12 U”,”value”:”12U”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”12 min 30 sec”,”value”:”12.5 minutes (9000 watts)”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”200 V, 208 V, 240 V”,”value”:”200V; 208V; 240V”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”200 V AC, 208 V AC, 240 V AC”,”value”:”200V AC; 208V AC; 240V AC”},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 6 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 6 hours from 10% to 90% (typical, full load discharge)”},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”0-3000m (0 to 10,000 ft.)”,”value”:”0-3000m (0 to 10,000 ft.)”},{“name”:”LED Indicators”,”normalizedValue”:”6 LEDs indicate line power, online mode, bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”,”value”:”6 LEDs indicate line power, online mode, bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”},{“name”:”Audible Alarm”,”normalizedValue”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”,”value”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”18,000″,”value”:”18000″},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Output Circuit Breakers”,”normalizedValue”:”Two built-in 30A breakers protect one L6-30R outlet each; Eight built-in 20A breakers protect one C19 outlet each”,”value”:”Two built-in 30A breakers protect one L6-30R outlet each; Eight built-in 20A breakers protect one C19 outlet each”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”20″,”value”:”20″},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”300V”,”value”:”300V”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”240″,”value”:”240″},{“name”:”Operating Elevation (m)”,”normalizedValue”:”0-3000 m”,”value”:”0-3000 m”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”20,000″,”value”:”20000″},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”9,185″,”value”:”9185″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”6,830″,”value”:”6830″},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fans”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4.3 minutes (18,000 watts)”,”value”:”4.3 minutes (18,000 watts)”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”131″,”value”:”131″},{“name”:”Maximum Device Depth (in.)”,”normalizedValue”:”32.5″,”value”:”32.5″},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Alarm cancel switch”,”value”:”Alarm cancel switch”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI)”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”125A @ 200V, 208V, 240V”,”value”:”125A @ 200V, 208V, or 240V (L1, L2, G)”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”,”value”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)”,”value”:”2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)”},{“name”:”Output Capacity Details”,”normalizedValue”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less”,”value”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”100V”,”value”:”100V”},{“name”:”Audible Noise”,”normalizedValue”:”60 dBA at front side 1 meter”,”value”:”60 dBA at front side 1 meter”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Runtime is expandable with external battery packs”,”value”:”Runtime is expandable with external battery packs”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Corrects overvoltages up to 300V”,”value”:”Corrects overvoltages up to 300V”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable external battery packs”,”value”:”Hot-swappable, user replaceable external battery packs”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP240V10RT3U; BP240V787C-1PH”,”value”:”BP240V10RT3U; BP240V787C-1PH”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”18″,”value”:”18″},{“name”:”Voltage Regulation Description”,”normalizedValue”:”2% output voltage regulation in standard online, double-conversion mode”,”value”:”2% output voltage regulation in standard online, double-conversion mode”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”2,565″,”value”:”2565″},{“name”:”UPS Certification Details”,”normalizedValue”:”IEC 61000-4-5 1995 B Surge Immunity”,”value”:”IEC 61000-4-5 1995 B Surge Immunity”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”5.14 x 17.5 x 25.82″,”value”:”5.14 x 17.5 x 25.82″},{“name”:”Communications Cable”,”normalizedValue”:”USB, DB9 serial and EPO cables included”,”value”:”USB, DB9 serial and EPO cables included”},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”37.5″,”value”:”37.5″},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)”,”value”:”Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”112.2A (200V), 108A (208V), 102A (220V), 97.6A (230V), 93.6A (240V)”,”value”:”112.2A (200V), 108A (208V), 102A (220V), 97.6A (230V), 93.6A (240V)”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Expandable Runtime Description”,”normalizedValue”:”For best results, add external batteries in multiples of two so that both included 10kVA power modules have an equal number and type of connected battery packs”,”value”:”For best results, add external batteries in multiples of two so that both included 10kVA power modules have an equal number and type of connected battery packs”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”8 hr”,”value”:”8 Hour”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Bypass Switch”,”normalizedValue”:”Automatic, Manual”,”value”:”Automatic, Manual”},{“name”:”Load Capacity”,”normalizedValue”:”20 kVA”,”value”:”20 kVA”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Output Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Additional Information”,”normalizedValue”:”Output Receptacles: 8 x C19″,”value”:”Output Receptacles: 8 x C19″},{“name”:”Package Contents”,”normalizedValue”:”SmartOnline EZ SU20KRT 20kVA Tower/Rack Mountable UPS, 2 x Power Modules, 2 x Battery Packs, L6-30R / C19 parallel PDU with Bypass switch, PowerAlert Software CD, USB Cable, Serial Cable, EPO Cable, 4 x Sets of Adjustable 4 Post Rack Rails”,”value”:”SmartOnline EZ SU20KRT 20kVA Tower/Rack Mountable UPS, 2 x Power Modules, 2 x Battery Packs, L6-30R / C19 parallel PDU with Bypass switch, PowerAlert Software CD, USB Cable, Serial Cable, EPO Cable, 4 x Sets of Adjustable 4 Post Rack Rails”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Modular Slots”,”normalizedValue”:”Communications Slot”,”value”:”Communications Slot”},{“name”:”Input Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Product Series”,”normalizedValue”:”EZ”,”value”:”EZ”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”Package Includes”,”normalizedValue”:”Two SU10000RT3UPM UPS power modules;Two BP240V10RT3U battery packs;SUPDMB20K parallel PDU with Bypass switch;4-post rackmount installation kits;USB, DB9 \u0026 EPO Cabling”,”value”:”Two SU10000RT3UPM UPS power modules;Two BP240V10RT3U battery packs;SUPDMB20K parallel PDU with Bypass switch;4-post rackmount installation kits;USB, DB9 \u0026 EPO Cabling”},{“name”:”UPS Applications”,”normalizedValue”:”Mission Critical Applications”,”value”:”Mission Critical Applications”},{“name”:”Unit Dimension Details”,”normalizedValue”:”Includes 2 SU10000RT3UPM UPS/Power modules, 2 BP240V10RT3U Battery packs and SUPDMB20K parallel bypass PDU; Listed weights and dimensions for UPS/Power module and Included battery pack each refer to a single unit; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with parallel bypass PDU installed”,”value”:”Includes 2 SU10000RT3UPM UPS/Power modules, 2 BP240V10RT3U Battery packs and SUPDMB20K parallel bypass PDU; Listed weights and dimensions for UPS/Power module and Included battery pack each refer to a single unit; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with parallel bypass PDU installed”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”18,000″,”value”:”18000″},{“name”:”Output Capacity (VA)”,”normalizedValue”:”20,000″,”value”:”20000″},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class A (USA)”,”value”:”FCC Part 15 Class A (USA)”},{“name”:”Product Certifications”,”normalizedValue”:”IEC 61000; CSA (Canada); UL 1778″,”value”:”IEC 61000; CSA (Canada); UL 1778″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Smart UPS, 20kVA, Online, Out: 230/208/200/240/220V AC In: 220V AC”