Description
[{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”1 kVA”,”rank”:2,”value”:”1.0 kVA”},{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”1 kVA”,”rank”:4,”value”:”1kVA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”800 W”,”rank”:6,”value”:”800 W”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”110/115/120V”,”rank”:8,”value”:”110/115/120V”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”14 min/4 min”,”rank”:9,”value”:”14 min/4 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”6″,”rank”:12,”value”:”6″},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, SNMP/Web Slot, USB”,”value”:”DB9 Serial, EPO, SNMP/Web Slot, USB”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Width”,”normalizedValue”:”17 in”,”value”:”17 in”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Input Current”,”normalizedValue”:”9.2 A”,”value”:”9.2 A”},{“name”:”Height”,”normalizedValue”:”2 in”,”value”:”2 in”},{“name”:”Includes”,”normalizedValue”:”DB9 Cable, EPO Cables, Mounting Hardware, SMART1000RM1U SmartPro120V 1kVA 800W Line-Interactive Sine Wave UPS, USB Cables”,”value”:”DB9 Cable, EPO Cables, Mounting Hardware, SMART1000RM1U SmartPro120V 1kVA 800W Line-Interactive Sine Wave UPS, USB Cables”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(6) 5-15R”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Special Features”,”normalizedValue”:”Advanced AVR Corrects Brownouts and Overvoltages, Pure Sine Wave Output”,”value”:”Advanced AVR Corrects Brownouts and Overvoltages, Pure Sine Wave Output”},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), FCC Part 15 Class a (USA), NOM (Mexico), RoHS, UL1778″,”value”:”CSA (Canada), FCC Part 15 Class a (USA), NOM (Mexico), RoHS, UL1778″},{“name”:”Footnotes”,”normalizedValue”:”3,4,10,12″,”value”:”3,4,10,12″},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Display Type”,”normalizedValue”:”LED”,”value”:”LED”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Transfer Time”,”normalizedValue”:”2 to 4 msec”,”value”:”2 to 4 msec”},{“name”:”Depth”,”normalizedValue”:”17 in”,”value”:”17 in”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Overall Height”,”normalizedValue”:”1-3/4 in”,”value”:”1.75 in”},{“name”:”Voltage”,”normalizedValue”:”120″,”value”:”120″},{“name”:”Overall Width”,”normalizedValue”:”17-1/2 in”,”value”:”17.5 in”},{“name”:”Capacity – Batteries”,”normalizedValue”:”1000 VA/800 W”,”value”:”1000 VA/800 W”},{“name”:”For Use with”,”normalizedValue”:”VoIP Phone System, Data Center, Computer”,”value”:”VoIP Phone System, Data Center, Computer”},{“name”:”Input Connection”,”normalizedValue”:”10 ft Cord with NEMA 5-15P Plug”,”value”:”10 ft Cord with NEMA 5-15P Plug”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”44″,”value”:”44″},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”1,000″,”value”:”1000″},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”83″,”value”:”83″},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”147″,”value”:”147″},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”19.75″,”value”:”19.75″},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.99″,”value”:”0.99″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communications ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communications ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 83 and 107 are boosted by 14%”,”value”:”Input voltages between 83 and 107 are boosted by 14%”},{“name”:”Expandable Runtime”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Communications Interface”,”normalizedValue”:”USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”LED Indicators”,”normalizedValue”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”,”value”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Battery Access”,”normalizedValue”:”Front panel battery access door”,”value”:”Front panel battery access door”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”UPS Certification Details”,”normalizedValue”:”UL 1778: 2014 R8.15 (5TH Edition); CAN/CSA-C22.2 NO. 107.3-14″,”value”:”UL 1778: 2014 R8.15 (5TH Edition); CAN/CSA-C22.2 NO. 107.3-14″},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”Included mounting brackets provide front-rail installation in 2 or 4 post racks; For additional stability in 4 post racks, consider optional 4 post mounting accessories 4POSTRAILKIT1U \u0026 4POSTRAILKITWM”,”value”:”Included mounting brackets provide front-rail installation in 2 or 4 post racks; For additional stability in 4 post racks, consider optional 4 post mounting accessories 4POSTRAILKIT1U \u0026 4POSTRAILKITWM”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure, overload and low-battery conditions”,”value”:”Audible alarm indicates power-failure, overload and low-battery conditions”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”425″,”value”:”425″},{“name”:”Grounding Lug”,”normalizedValue”:”Back panel grounding lug”,”value”:”Back panel grounding lug”},{“name”:”Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”4.5 hours from 10% to 90% (typical, full load discharge)”,”value”:”4.5 hours from 10% to 90% (typical, full load discharge)”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147″},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 128 and 147 are reduced by 12%”,”value”:”Input voltages between 128 and 147 are reduced by 12%”},{“name”:”Audible Noise”,”normalizedValue”:”45 dBA maximum, front side 1m”,”value”:”45 dBA maximum, front side 1m”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”800″,”value”:”800″},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 cabling included”,”value”:”USB and DB9 cabling included”},{“name”:”AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”14 min”,”value”:”14 min. (400w)”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-21%, +8%”,”value”:”-21%, +8%”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”2 post 19 inch rackmount; 4 post 19 inch rackmount”,”value”:”2 post 19 inch rackmount; 4 post 19 inch rackmount”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min”,”value”:”4 min. (800w)”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”1.75 x 17.5 x 16.75″,”value”:”1.75 x 17.5 x 16.75″},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”Load Management Receptacles”,”normalizedValue”:”Two switchable single-outlet 5-15R load banks”,”value”:”Two switchable single-outlet 5-15R load banks”},{“name”:”UPS Certifications”,”normalizedValue”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”,”value”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”450″,”value”:”450″},{“name”:”Input Circuit Breakers”,”normalizedValue”:”15A”,”value”:”15A”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”9 A”,”value”:”9A”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions”,”value”:”Supports detailed monitoring of UPS and site power conditions”},{“name”:”Power Factor”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”39″,”value”:”39″},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”4 post rackmount full-depth ( 4POSTRAILKIT1U ); 4 post rackmount short-depth ( 4POSTRAILKITWM )”,”value”:”4 post rackmount full-depth ( 4POSTRAILKIT1U ); 4 post rackmount short-depth ( 4POSTRAILKITWM )”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC69-1U”,”value”:”RBC69-1U”},{“name”:”Rack Height”,”normalizedValue”:”1 U”,”value”:”1U”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Package Contents”,”normalizedValue”:”SmartPro 1000RM1U UPS, SMART 1000RM1U UPS System, Mounting hardware, Cabling for USB \u0026 DB9 monitoring and EPO switching, PowerAlert unattended shutdown and UPS/Power monitoring software, Warranty information and instruction manual”,”value”:”SmartPro 1000RM1U UPS, SMART 1000RM1U UPS System, Mounting hardware, Cabling for USB \u0026 DB9 monitoring and EPO switching, PowerAlert unattended shutdown and UPS/Power monitoring software, Warranty information and instruction manual”},{“name”:”Waveform Type”,”normalizedValue”:”Pure Sinusoidal”,”value”:”Pure Sinusoidal”},{“name”:”Form Factor”,”normalizedValue”:”Rack-mountable”,”value”:”Rack-mountable”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr 30 min”,”value”:”4.50 Hour”},{“name”:”Application/Usage”,”normalizedValue”:”Data Center, Computer, VoIP Phone System”,”value”:”Data Center, Computer, VoIP Phone System”},{“name”:”Load Capacity”,”normalizedValue”:”1000 VA/800 W”,”value”:”1000 VA/800 W”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); NOM (Mexico); UL 1778″,”value”:”CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class A (USA)”,”value”:”FCC Part 15 Class A (USA)”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”1,000″,”value”:”1000″},{“name”:”Package Includes”,”normalizedValue”:”SMART1000RM1U SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS;USB cable;DB9 cable;EPO cable;Mounting hardware;Owner’s manual”,”value”:”SMART1000RM1U SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS;USB cable;DB9 cable;EPO cable;Mounting hardware;Owner’s manual”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”800″,”value”:”800″},{“name”:”UPS Applications”,”normalizedValue”:”Large Network; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality”,”value”:”Large Network; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality”},{“name”:”Grounding Details”,”normalizedValue”:”Back panel grounding lug”,”value”:”Back panel grounding lug”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage”,”value”:”Low Battery, Overload, Power Outage”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Battery Recharge Time”,”normalizedValue”:”4 hr 30 min”,”value”:”4.5 hr”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”External Battery Compatible”,”normalizedValue”:”Not External Battery Pack Compatible”,”value”:”Not External Battery Pack Compatible”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”450 J”,”value”:”450 J”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Overall Depth”,”normalizedValue”:”16.7 in”,”value”:”16.7 in”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Power Rating – Real”,”normalizedValue”:”800 W”,”value”:”800 W”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, SNMP, USB”,”value”:”DB9 Serial, EPO, SNMP, USB”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Input Current – Maximum”,”normalizedValue”:”9.2 A”,”value”:”9.2 A”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.