[{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”2.2 kVA”,”rank”:2,”value”:”2.2 kVA”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”1.95 kVA”,”rank”:4,”value”:”1.95kVA”},{“name”:”Mounting”,”normalizedValue”:”Tower, Rack”,”rank”:5,”value”:”Rack/Tower”},{“name”:”Wattage”,”normalizedValue”:”1.95 kW”,”rank”:6,”value”:”1.95 kW”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”100/110/120/125V AC”,”rank”:8,”value”:”100/110/120/125V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”12 min/4 min”,”rank”:9,”value”:”12 min/4 min”},{“name”:”Outlet Type”,”normalizedValue”:”(4) Surge; (4) UPS/Surge”,”rank”:10,”value”:”(4) Surge; (4) UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”8″,”rank”:12,”value”:”8″},{“name”:”Includes”,”normalizedValue”:”(4) Post Rack Mount Installation Kits, PowerAlert Software with USB, Serial and EPO Cables”,”value”:”(4) Post Rack Mount Installation Kits, PowerAlert Software with USB, Serial and EPO Cables”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Transfer Time”,”normalizedValue”:”2 to 4 msec”,”value”:”2 to 4 msec”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R; 5-15/20R”,”value”:”(4) 5-15R; (4) 5-15/20R”},{“name”:”Width”,”normalizedValue”:”19 in”,”value”:”19 in”},{“name”:”Height”,”normalizedValue”:”4 in”,”value”:”4 in”},{“name”:”Special Features”,”normalizedValue”:”Advanced AVR Corrects Brownouts and Overvoltages, Pure Sine Wave Output, Extended Runtime w/BP48V24-2U and BP48V60RT-3U”,”value”:”Advanced AVR Corrects Brownouts and Overvoltages, Pure Sine Wave Output, Extended Runtime w/BP48V24-2U and BP48V60RT-3U”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Footnotes”,”normalizedValue”:”1,2,3,4,10,12″,”value”:”1,2,3,4,10,12″},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Depth”,”normalizedValue”:”19 in”,”value”:”19 in”},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, SNMP/Web Slot, USB (HID Enabled)”,”value”:”DB9 Serial, EPO, SNMP/Web Slot, USB (HID Enabled)”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-20P”,”value”:”5-20P”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Input Current”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Standards”,”normalizedValue”:”CE (Europe), CSA (Canada), ENERGY STAR Qualified, FCC Part 15 Class B (USA), UL1778″,”value”:”CE (Europe), CSA (Canada), ENERGY STAR Qualified, FCC Part 15 Class B (USA), UL1778″},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Voltage”,”normalizedValue”:”120″,”value”:”120″},{“name”:”Overall Width”,”normalizedValue”:”17 in”,”value”:”17 in”},{“name”:”Overall Height”,”normalizedValue”:”3.4 in”,”value”:”3.4 in”},{“name”:”Operating Temp. Range”,”normalizedValue”:”104\u0026deg;F (40\u0026deg;C)”,”value”:”104\u0026deg;F (40\u0026deg;C)”},{“name”:”Capacity – Batteries”,”normalizedValue”:”2200 VA/1920 W”,”value”:”2200 VA/1920 W”},{“name”:”Input Connection”,”normalizedValue”:”10 ft Cord with NEMA 5-20P Plug”,”value”:”10 ft Cord with NEMA 5-20P Plug”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 4.5 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 4.5 hours from 10% to 90% (typical, full load discharge)”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Voltage reduction of 12% applies when input is between 127 and 145″,”value”:”Voltage reduction of 12% applies when input is between 127 and 145″},{“name”:”Battery Access”,”normalizedValue”:”Front panel battery access door”,”value”:”Front panel battery access door”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,157″,”value”:”1157″},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC94-2U”,”value”:”RBC94-2U”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”20A 120V”,”value”:”20A 120V”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145″},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions”,”value”:”Supports detailed monitoring of UPS and site power conditions”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”,”value”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Switches”,”normalizedValue”:”3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions”,”value”:”3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions”},{“name”:”Network UPS Tools Compatibility”,”normalizedValue”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”,”value”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”,”value”:”2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”},{“name”:”Minimum Required Rack Depth without External Battery Pack (in.)”,”normalizedValue”:”24.29″,”value”:”24.29″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”Grounding Lug”,”normalizedValue”:”Back panel grounding lug”,”value”:”Back panel grounding lug”},{“name”:”Audible Noise”,”normalizedValue”:”45 dBA maximum, front side 1m”,”value”:”45 dBA maximum, front side 1m”},{“name”:”Output Capacity Details”,”normalizedValue”:”Output is reduced to 1600 watts maximum when used with external battery packs”,”value”:”Output is reduced to 1600 watts maximum when used with external battery packs”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”306″,”value”:”306″},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”88″,”value”:”88″},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”1,920″,”value”:”1920″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Load Management Receptacles”,”normalizedValue”:”Two switched single outlet load banks (1 5-15/20R \u0026 1 5-15R)”,”value”:”Two switched single outlet load banks (1 5-15/20R \u0026 1 5-15R)”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”2,200″,”value”:”2200″},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)”,”value”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)”},{“name”:”Minimum Required Rack Depth with External Battery Pack (in.)”,”normalizedValue”:”26.29″,”value”:”26.29″},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”145″,”value”:”145″},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Voltage boost of 24% applies when input voltage is between 83 and 95″,”value”:”Voltage boost of 24% applies when input voltage is between 83 and 95″},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”12 min”,”value”:”12 min. (960w)”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Voltage boost of 12% applies when input voltage is between 96 and 108″,”value”:”Voltage boost of 12% applies when input voltage is between 96 and 108″},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery packs”,”value”:”Extended runtime supported via optional external battery packs”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+6%, -14%”,”value”:”-14%, +6%”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”16 A”,”value”:”16.0A”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.96″,”value”:”0.96″},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”48″,”value”:”48″},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”,”value”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”UPS Certifications”,”normalizedValue”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”,”value”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)”,”value”:”BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)”},{“name”:”Rack Height”,”normalizedValue”:”2 U”,”value”:”2U”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”490″,”value”:”490″},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”2.2″,”value”:”2.2″},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”83″,”value”:”83″},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 cabling included”,”value”:”USB and DB9 cabling included”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”1.92″,”value”:”1.92″},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”570″,”value”:”570″},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min 30 sec”,”value”:”4.5 min. (1920w)”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”,”value”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”},{“name”:”Expandable Runtime Description”,”normalizedValue”:”Maximum output capacity is 1600 watts when used with external battery packs”,”value”:”Maximum output capacity is 1600 watts when used with external battery packs”},{“name”:”Power Factor”,”normalizedValue”:”0.87″,”value”:”0.87″},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”3.46 x 17.32 x 19.29″,”value”:”3.46 x 17.32 x 19.29″},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Alarm”,”normalizedValue”:”On Battery, Overload, Low Battery”,”value”:”On Battery, Overload, Low Battery”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”104°F”,”value”:”104°F (40°C)”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Package Contents”,”normalizedValue”:”SMART2200RMXL2U UPS System, Poweralert Software CD-ROM, USB, Serial And EPO Cabling, Owner’s Manual”,”value”:”SMART2200RMXL2U UPS System, Poweralert Software CD-ROM, USB, Serial And EPO Cabling, Owner’s Manual”},{“name”:”Protection Type”,”normalizedValue”:”Under Voltage”,”value”:”Under Voltage, Over Voltage”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Load Capacity”,”normalizedValue”:”1950 VA/1950 W”,”value”:”1950 VA/1950 W”},{“name”:”Status Indicators”,”normalizedValue”:”5 Front Panel Leds: Green Power Led, Green Voltage Correction Led, 3 Color Battery Charge Led, 3 Color Output Load Led, Red Battery Warning Led”,”value”:”5 Front Panel Leds: Green Power Led, Green Voltage Correction Led, 3 Color Battery Charge Led, 3 Color Output Load Led, Red Battery Warning Led”},{“name”:”Waveform Type”,”normalizedValue”:”Sine Wave”,”value”:”Sine Wave”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr 30 min”,”value”:”4.50 Hour”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-15R, 5-20R”,”value”:”5-15R, 5-20R”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Overall Depth”,”normalizedValue”:”23.7 in”,”value”:”23.7 in”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”380 J”,”value”:”380 J”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage”,”value”:”Low Battery, Overload, Power Outage”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”7″,”value”:”7″},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Power Rating – Real”,”normalizedValue”:”1.6 kW”,”value”:”1.6 kW”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Input Current – Maximum”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Battery Recharge Time”,”normalizedValue”:”4 hr 30 min”,”value”:”4.5 hr”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr, 3 yr (Registration)”,”value”:”2 yr, 3 yr Registration”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, SNMP, USB”,”value”:”DB9 Serial, EPO, SNMP, USB”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.