Smart UPS, 10kVA, Online/Double Conversion, Out: 120/208V AC In: 208V AC

$8601,99

Smart UPS, Online Double Conversion, Power Rating 10 kVA, Wattage 8 kW, Input Voltage 208V AC, Output Voltage 120V AC, 208V AC, Backup Time (Half/Full Load) 12.5 min/4.3 min, Mounting Rack/Tower, Outlet Type UPS/Surge, Number of Outlets 30, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration 5-20R, L6-20R, L6-30R, NEMA Plug Configuration Hardwire, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 0 msec, Width 18 in, Depth 26 in, Height 5 in

Out of stock

SKU: GRG2228436 Category:

Description

[{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”10 kVA”,”rank”:2,”value”:”10.0 kVA”},{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”Watts – UPS Systems”,”normalizedValue”:”8 kW”,”rank”:3,”value”:”8.0 kW”},{“name”:”UPS Type”,”normalizedValue”:”Online, Double Conversion”,”rank”:3,”value”:”Online/Double Conversion”},{“name”:”Power Rating”,”normalizedValue”:”10 kVA”,”rank”:4,”value”:”10kVA”},{“name”:”Input Voltage – UPS Systems”,”normalizedValue”:”208V AC”,”rank”:4,”value”:”208V AC”},{“name”:”Mounting”,”normalizedValue”:”Tower, Rack”,”rank”:5,”value”:”Rack/Tower”},{“name”:”Output Voltage – UPS Systems”,”normalizedValue”:”120V AC, 208V AC”,”rank”:5,”value”:”120V AC, 208V AC”},{“name”:”Wattage”,”normalizedValue”:”9 kW”,”rank”:6,”value”:”9 kW”},{“name”:”Input Voltage”,”normalizedValue”:”208V AC”,”rank”:7,”value”:”208V AC”},{“name”:”Output Voltage”,”normalizedValue”:”120/208V AC”,”rank”:8,”value”:”120/208V AC”},{“name”:”Outlet Type – UPS Systems”,”normalizedValue”:”UPS/Surge”,”rank”:8,”value”:”UPS/Surge”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”12.5 min/4.3 min”,”rank”:9,”value”:”12.5 min/4.3 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”30″,”rank”:12,”value”:”30″},{“name”:”Special Features”,”normalizedValue”:”True Online Protection with Pure Sine Wave Output, Use in Economy Mode to Save Operating Costs, Extended Runtime Option with BP240V10RT3U, Hot-Swappable Feature Lets Users Replace/Repair UPS without Powering Down Connected Equipment,”,”value”:”True Online Protection with Pure Sine Wave Output, Use in Economy Mode to Save Operating Costs, Extended Runtime Option with BP240V10RT3U, Hot-Swappable Feature Lets Users Replace/Repair UPS without Powering Down Connected Equipment,”},{“name”:”Transfer Time”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Width”,”normalizedValue”:”18 in”,”value”:”18 in”},{“name”:”Ports”,”normalizedValue”:”Contact Closure, DB9 Serial, EPO, SNMP/Web Slot, USB (HID Enabled)”,”value”:”Contact Closure, DB9 Serial, EPO, SNMP/Web Slot, USB (HID Enabled)”},{“name”:”Depth”,”normalizedValue”:”26 in”,”value”:”26 in”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L6-30R, 5-20R, L6-20R”,”value”:”5-20R, L6-20R, L6-30R”},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), FCC Part 15 Class a (USA), IEC 61000, NOM (Mexico), RoHS, UL1778″,”value”:”CSA (Canada), FCC Part 15 Class a (USA), IEC 61000, NOM (Mexico), RoHS, UL1778″},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Mounting – UPS Systems”,”normalizedValue”:”Rack, Tower”,”value”:”Rack/Tower”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Includes”,”normalizedValue”:”(2) SU5000XFMRT2U Step Down Transformers, (4) Post Compatible Rack Rail Kit (4 Sets), BP240V10RT3U External Battery Pack, SUPDMB710 Detachable PDU with Manual Bypass Switch, Tower Stands, USB, DB9 and EPO Cabling”,”value”:”(2) SU5000XFMRT2U Step Down Transformers, (4) Post Compatible Rack Rail Kit (4 Sets), BP240V10RT3U External Battery Pack, SUPDMB710 Detachable PDU with Manual Bypass Switch, Tower Stands, USB, DB9 and EPO Cabling”},{“name”:”Footnotes”,”normalizedValue”:”1,2,3,12″,”value”:”1,2,3,12″},{“name”:”Input Current”,”normalizedValue”:”54 A”,”value”:”54 A”},{“name”:”Height”,”normalizedValue”:”5 in”,”value”:”5 in”},{“name”:”Cord Length”,”normalizedValue”:”No Cord”,”value”:”No Cord”},{“name”:”Watts”,”normalizedValue”:”8,000″,”value”:”8kW”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”Hardwire”,”value”:”Hardwire”},{“name”:”Green Certification or Other Recognition”,”normalizedValue”:”UL1778CSACENOMClass A (Emissions)”,”value”:”UL1778CSACENOMClass A (Emissions)”},{“name”:”Overall Height”,”normalizedValue”:”5.16 in”,”value”:”5.16 in”},{“name”:”Overall Width”,”normalizedValue”:”17.52 in”,”value”:”17.52 in”},{“name”:”Voltage”,”normalizedValue”:”120/208″,”value”:”120/208″},{“name”:”Capacity – Batteries”,”normalizedValue”:”10000 VA/8000 W”,”value”:”10000 VA/8000 W”},{“name”:”Backup/Run Time (Full Load)”,”normalizedValue”:”6 Minute/12 Minute”,”value”:”6 Minute/12 Minute”},{“name”:”Input Connection”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Battery Type”,”normalizedValue”:”Lead Acid”,”value”:”Valve Regulated Lead Acid (VRLA)”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”60A”,”value”:”60A”},{“name”:”Communications Cable”,”normalizedValue”:”USB, DB9 serial and EPO cables included”,”value”:”USB, DB9 serial and EPO cables included”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”5.14 x 17.5 x 25.82″,”value”:”5.14 x 17.5 x 25.82″},{“name”:”Maximum Device Depth (in.)”,”normalizedValue”:”32.5″,”value”:”32.5″},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 6 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 6 hours from 10% to 90% (typical, full load discharge)”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Audible Alarm”,”normalizedValue”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”,”value”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”2,565″,”value”:”2565″},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”10,000″,”value”:”10000″},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Transfer Time (Economy Mode)”,”normalizedValue”:”8 ms. typical power failure response in optional economy mode”,”value”:”8 ms. typical power failure response in optional economy mode”},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”445″,”value”:”445″},{“name”:”UPS Certification Details”,”normalizedValue”:”IEC 61000-4-5 1995 B Surge Immunity”,”value”:”IEC 61000-4-5 1995 B Surge Immunity”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)”,”value”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)”},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”0-3000m (0 to 10,000 ft.)”,”value”:”0-3000m (0 to 10,000 ft.)”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”4,593″,”value”:”4593″},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”9″,”value”:”9″},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min 18 sec”,”value”:”4.3 min. (9000w)”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITHD )”,”value”:”2 post rackmount ( 2POSTRMKITHD )”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable external battery packs”,”value”:”Hot-swappable, user replaceable external battery packs”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”131″,”value”:”131″},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”54A (208V)”,”value”:”54A (208V)”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”3,415″,”value”:”3415″},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,280″,”value”:”1280″},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Alarm cancel switch”,”value”:”Alarm cancel switch”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Output Receptacles”,”normalizedValue”:”5-15/20R, L6-30R, L6-20R”,”value”:”(24) 5-15/20R; (4) L6-20R; (2) L6-30R”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports”,”value”:”Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”4 sets of adjustable 4 post rack rails included; Tower stands are included to support the entire 10U UPS bundle in upright tower configuration”,”value”:”4 sets of adjustable 4 post rack rails included; Tower stands are included to support the entire 10U UPS bundle in upright tower configuration”},{“name”:”Operating Elevation (m)”,”normalizedValue”:”0-3000 m”,”value”:”0-3000 m”},{“name”:”UPS Dimensions Details”,”normalizedValue”:”Includes 3U UPS/power module, 3U battery pack, Two 2U SU5000XFMRT2U step down transformers plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”,”value”:”Includes 3U UPS/power module, 3U battery pack, Two 2U SU5000XFMRT2U step down transformers plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”208 V AC”,”value”:”208V AC”},{“name”:”UPS Input Connection Type”,”normalizedValue”:”Hardwire”,”value”:”Hardwire”},{“name”:”Output Capacity Details”,”normalizedValue”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less”,”value”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less”},{“name”:”Output Circuit Breakers”,”normalizedValue”:”20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlets each, 20A single-pole (x8) protect 3 5-15/20R outlets each”,”value”:”20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlets each, 20A single-pole (x8) protect 3 5-15/20R outlets each”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Supports extended runtime with optional external battery packs”,”value”:”Supports extended runtime with optional external battery packs”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”120 V, 208 V”,”value”:”120V; 208V”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”12 min 30 sec”,”value”:”12.5 min. (4500w)”},{“name”:”Nominal Voltage Details”,”normalizedValue”:”Voltage selection via front panel LCD interface; This configuration requires the Power Module be set to 208V output voltage; Included step-down transformers support 120V output”,”value”:”Voltage selection via front panel LCD interface; This configuration requires the Power Module be set to 208V output voltage; Included step-down transformers support 120V output”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”,”value”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”},{“name”:”LED Indicators”,”normalizedValue”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”,”value”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”},{“name”:”Economy Mode Operation”,”normalizedValue”:”Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.”,”value”:”Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”240″,”value”:”240″},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”UPS Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Power Factor”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD”},{“name”:”Rack Height”,”normalizedValue”:”10 U”,”value”:”10U”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”300V”,”value”:”300V”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.91″,”value”:”0.91″},{“name”:”Stepdown Transformer Dimensions (hwd / in.)”,”normalizedValue”:”3.5 x 17.5 x 20.8″,”value”:”3.5 x 17.5 x 20.8″},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”37.5″,”value”:”37.5″},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”100V”,”value”:”100V”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP240V10RT3U ; BP240V787C-1PH”,”value”:”BP240V10RT3U ; BP240V787C-1PH”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”656″,”value”:”656″},{“name”:”Output Isolation Transformer”,”normalizedValue”:”120V output is isolation transformer protected”,”value”:”120V output is isolation transformer protected”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”2% output voltage regulation in standard online, double-conversion mode”,”value”:”2% output voltage regulation in standard online, double-conversion mode”},{“name”:”UPS Input Connection Description”,”normalizedValue”:”3 wire single phase input (L1, L2, G)”,”value”:”3 wire single phase input (L1, L2, G)”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output frequency regulation +/- 0.05Hz (free running)”,”value”:”Output frequency regulation +/- 0.05Hz (free running)”},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.96″,”value”:”0.96″},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement”},{“name”:”Frequency Compatibility”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Corrects undervoltages as low as 100V”,”value”:”Corrects undervoltages as low as 100V”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”9,000″,”value”:”9000″},{“name”:”Audible Noise”,”normalizedValue”:”60 dBA at front side 1 meter”,”value”:”60 dBA at front side 1 meter”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Corrects overvoltages up to 300V”,”value”:”Corrects overvoltages up to 300V”},{“name”:”Package Contents”,”normalizedValue”:”SmartOnline 10000VA Rack-mountable/Tower UPS with Two Step-down Transformers, 3U power module with detachable hot-swap PDU input/output panel and manaul bypass switch, 3U external battery pack, 2 x 2U step-down transformers, Two sets of 4-post rackmount rails (one for each 3U component); one set of towe”,”value”:”SmartOnline 10000VA Rack-mountable/Tower UPS with Two Step-down Transformers, 3U power module with detachable hot-swap PDU input/output panel and manaul bypass switch, 3U external battery pack, 2 x 2U step-down transformers, Two sets of 4-post rackmount rails (one for each 3U component); one set of towe”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Load Capacity”,”normalizedValue”:”10000 VA/8000 W”,”value”:”10000 VA/8000 W”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Receptacle Detail”,”normalizedValue”:”24 x NEMA L6-30R, 4 x NEMA 5-15/20R, 2 x NEMA L6-20R”,”value”:”24 x NEMA L6-30R, 4 x NEMA 5-15/20R, 2 x NEMA L6-20R”},{“name”:”Plug/Connector Type”,”normalizedValue”:”Hard Wire 3-wire”,”value”:”Hard Wire 3-wire”},{“name”:”Certifications \u0026 Standards”,”normalizedValue”:”UL1778, CSA, CE, NOM, Class A (Emissions)”,”value”:”UL1778, CSA, CE, NOM, Class A (Emissions)”},{“name”:”Bypass Switch”,”normalizedValue”:”Manual”,”value”:”Manual”},{“name”:”Product Type”,”normalizedValue”:”Double Conversion Online UPS”,”value”:”Double Conversion Online UPS”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”8 hr”,”value”:”8 Hour”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert UPS monitoring software”,”value”:”PowerAlert UPS monitoring software”},{“name”:”Backup/Run Time (Half Load)”,”normalizedValue”:”12 min”,”value”:”12 Minute”},{“name”:”Additional Information”,”normalizedValue”:”Cold Start Capable, AC suppression response time: Instantaneous, Appearance: Attractive black steel rackmount housing”,”value”:”Cold Start Capable, AC suppression response time: Instantaneous, Appearance: Attractive black steel rackmount housing”},{“name”:”Product Line”,”normalizedValue”:”SmartOnline”,”value”:”SmartOnline”},{“name”:”Product Name”,”normalizedValue”:”SmartOnline 10000VA Rack-mountable/Tower UPS with Two Step-down Transformers”,”value”:”SmartOnline 10000VA Rack-mountable/Tower UPS with Two Step-down Transformers”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Runtime Full Load (min.)”,”normalizedValue”:”4 min 18 sec”,”value”:”4.3 min. (9000W)”},{“name”:”Unit Dimension Details”,”normalizedValue”:”Includes 3U UPS/power module, 3U battery pack, Two 2U SU5000XFMRT2U step down transformers plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”,”value”:”Includes 3U UPS/power module, 3U battery pack, Two 2U SU5000XFMRT2U step down transformers plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”10,000″,”value”:”10000″},{“name”:”UPS Applications”,”normalizedValue”:”Mission Critical Applications”,”value”:”Mission Critical Applications”},{“name”:”Online Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”3,415″,”value”:”3415″},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class A (USA)”,”value”:”FCC Part 15 Class A (USA)”},{“name”:”Product Certifications”,”normalizedValue”:”IEC 61000; CSA (Canada); NOM (Mexico); UL 1778″,”value”:”IEC 61000; CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”Battery Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”4,593″,”value”:”4593″},{“name”:”Runtime Half Load (min.)”,”normalizedValue”:”12 min 30 sec”,”value”:”12.5 min. (4500W)”},{“name”:”Package Includes”,”normalizedValue”:”SU10000RT3UPM 3U UPS power module;BP240V10RT3U external battery pack;Two SU5000XFMRT2U step down transformers;SUPDMB710 Detachable PDU with manual bypass switch;Four post compatible rack rail kit (4 sets);Tower stands;USB, DB9 and EPO Cabling;User manual”,”value”:”SU10000RT3UPM 3U UPS power module;BP240V10RT3U external battery pack;Two SU5000XFMRT2U step down transformers;SUPDMB710 Detachable PDU with manual bypass switch;Four post compatible rack rail kit (4 sets);Tower stands;USB, DB9 and EPO Cabling;User manual”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”9,000″,”value”:”9000″},{“name”:”Run Time – Full Load”,”normalizedValue”:”4 min 18 sec”,”value”:”4.3 min”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Overall Depth”,”normalizedValue”:”25.83 in”,”value”:”25.83 in”},{“name”:”Input Current – Maximum”,”normalizedValue”:”54 A”,”value”:”54 A”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Power Rating – Real”,”normalizedValue”:”9 kW”,”value”:”9 kW”},{“name”:”Transfer Time – Maximum”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”30″,”value”:”30″},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-20R, L6-30R, L6-20R”,”value”:”5-20R, L6-20R, L6-30R”},{“name”:”Plug Configuration”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP240V10RT3U, BP240V787C-1PH”,”value”:”BP240V10RT3U, BP240V787C-1PH”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Run Time – Half Load”,”normalizedValue”:”12 min 30 sec”,”value”:”12.5 min”},{“name”:”Power Cord Length”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Number of Outlets – UPS”,”normalizedValue”:”30″,”value”:”30″},{“name”:”Surge Suppression Rating”,”normalizedValue”:”2,565 J”,”value”:”2,565 J”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Battery Recharge Time”,”normalizedValue”:”6 hr”,”value”:”6 hr”},{“name”:”Power Rating – Apparent”,”normalizedValue”:”10 kVA”,”value”:”10 kVA”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Smart UPS, 10kVA, Online/Double Conversion, Out: 120/208V AC In: 208V AC”