Description
[{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”UPS Type”,”normalizedValue”:”Online”,”rank”:3,”value”:”Online”},{“name”:”Power Rating”,”normalizedValue”:”1,000 VA”,”rank”:4,”value”:”1000VA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”800 W”,”rank”:6,”value”:”800 W”},{“name”:”Input Voltage”,”normalizedValue”:”100/120/110V AC”,”rank”:7,”value”:”100/120/110V AC”},{“name”:”Output Voltage”,”normalizedValue”:”100/120/110V AC”,”rank”:8,”value”:”100/120/110V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”14 min/4.5 min”,”rank”:9,”value”:”14 min/4.5 min”},{“name”:”Number of Outlets”,”normalizedValue”:”6″,”rank”:12,”value”:”6″},{“name”:”Height”,”normalizedValue”:”3-1/2 in”,”value”:”3.5 in”},{“name”:”Width”,”normalizedValue”:”13-1/2 in”,”value”:”13.5 in”},{“name”:”Transfer Time”,”normalizedValue”:”No transfer time (0 ms.) in online, double-conversion mode”,”value”:”No transfer time (0 ms.) in online, double-conversion mode”},{“name”:”Depth”,”normalizedValue”:”13-1/2 in”,”value”:”13.5 in”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(6) 5-15R”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”2% output voltage regulation during undervoltages to 65 (under 70% load only)”,”value”:”2% output voltage regulation during undervoltages to 65 (under 70% load only)”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”444″,”value”:”444″},{“name”:”Power Factor”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Includes pre-installed WEBCARDLX Network Management Card; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR installed Network Management Card”,”value”:”Includes pre-installed WEBCARDLX Network Management Card; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR installed Network Management Card”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”80V (100% load), 65V ( \u003c70% load)”,”value”:”80V (100% load), 65V ( \u003c70% load)”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”150″,”value”:”150″},{“name”:”Battery Access”,”normalizedValue”:”Front panel battery access door”,”value”:”Front panel battery access door”},{“name”:”Overvoltage Correction”,”normalizedValue”:”2% output voltage regulation during overvoltages to 150″,”value”:”2% output voltage regulation during overvoltages to 150″},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Rack Height”,”normalizedValue”:”2 U”,”value”:”2U”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”114″,”value”:”114″},{“name”:”Output Capacity Details”,”normalizedValue”:”OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and \u003e150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”,”value”:”OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and \u003e150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”,”value”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible); BP24V36-2US (multi-pack compatible)”,”value”:”BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible); BP24V36-2US (multi-pack compatible)”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min 30 sec”,”value”:”4.5 min. (800w)”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”,”value”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”89″,”value”:”89″},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Online, double-conversion power conditioning”,”value”:”Online, double-conversion power conditioning”},{“name”:”Minimum Required Rack Depth with External Battery Pack (in.)”,”normalizedValue”:”16.5″,”value”:”16.5″},{“name”:”Communications Cable”,”normalizedValue”:”Micro-USB, USB and DB9 cabling included”,”value”:”Micro-USB, USB and DB9 cabling included”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery packs”,”value”:”Extended runtime supported via optional external battery packs”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start”,”value”:”Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”8.6 A”,”value”:”8.6A”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”EPO Port”,”normalizedValue”:”RJ11 interface jack with 4-meter cable included. Supports normally open and normally closed EPO systems”,”value”:”RJ11 interface jack with 4-meter cable included. Supports normally open and normally closed EPO systems”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”1,000″,”value”:”1000″},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”100 V AC, 110 V AC, 120 V AC”,”value”:”100V AC; 110V AC; 120V AC”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 6 hours from 10% to 80% (typical, full load discharge)”,”value”:”Less than 6 hours from 10% to 80% (typical, full load discharge)”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”100 V, 110 V, 120 V”,”value”:”100V; 110V; 120V”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Hot swappable batteries”,”value”:”Automatic inverter bypass; Hot swappable batteries”},{“name”:”LED Indicators”,”normalizedValue”:”14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats. Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing), 100 Mbps (On steady). LX Platform Interface Status: Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec).”,”value”:”14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats. Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing), 100 Mbps (On steady). LX Platform Interface Status: Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec).”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”15A”,”value”:”15A”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”3.5 x 17.5 x 13.5″,”value”:”3.5 x 17.5 x 13.5″},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”,”value”:”2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”},{“name”:”Undervoltage Correction”,”normalizedValue”:”2% output voltage regulation during undervoltages to 80″,”value”:”2% output voltage regulation during undervoltages to 80″},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”343″,”value”:”343″},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”510″,”value”:”510″},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”,”value”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”800″,”value”:”800″},{“name”:”Switches”,”normalizedValue”:”2 switches control off/on power status and alarm-cancel/self-test operation. LX Platform Interface: Recessed reset switch for interface reboot and factory reset”,”value”:”2 switches control off/on power status and alarm-cancel/self-test operation. LX Platform Interface: Recessed reset switch for interface reboot and factory reset”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”SNMP Compatibility”,”normalizedValue”:”V3, SNMP V1, V2c”,”value”:”SNMP V1, V2c, V3″},{“name”:”Communications Interface”,”normalizedValue”:”Contact closure; DB9 Serial; EPO (emergency power off); Micro-USB; Pre-installed network card; RJ45 Network; Slot for SNMP/Web interface; USB (HID enabled); USB-A; USB-B”,”value”:”Contact closure; DB9 Serial; EPO (emergency power off); Micro-USB; Pre-installed network card; RJ45 Network; Slot for SNMP/Web interface; USB (HID enabled); USB-A; USB-B”},{“name”:”Load Management Receptacles”,”normalizedValue”:”Two switchable single-outlet 5-15R load banks”,”value”:”Two switchable single-outlet 5-15R load banks”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.87″,”value”:”0.87″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”408″,”value”:”408″},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.96″,”value”:”0.96″},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC92-2U”,”value”:”RBC92-2U”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”1″,”value”:”1″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”14 min”,”value”:”14 min. (400w)”},{“name”:”Minimum Required Rack Depth without External Battery Pack (in.)”,”normalizedValue”:”16.5″,”value”:”16.5″},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI)”},{“name”:”Package Contents”,”normalizedValue”:”SmartOnline SU1000RTXL2UN 1kVA Tower/Rack Mountable, PowerAlert Software and Cabling, Mounting Hardware for 4-post Rack Enclosures, Instruction Manual”,”value”:”SmartOnline SU1000RTXL2UN 1kVA Tower/Rack Mountable, PowerAlert Software and Cabling, Mounting Hardware for 4-post Rack Enclosures, Instruction Manual”},{“name”:”Load Capacity”,”normalizedValue”:”1000 VA/800 W”,”value”:”1000 VA/800 W”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); UL 1778″,”value”:”CSA (Canada); UL 1778″},{“name”:”Online Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”408″,”value”:”408″},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLXE”,”value”:”WEBCARDLXE”},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class B (USA)”,”value”:”FCC Part 15 Class B (USA)”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”1,000″,”value”:”1000″},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”17″,”value”:”17″},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”800″,”value”:”800″},{“name”:”Package Includes”,”normalizedValue”:”SU1000RTXL2Ua with pre-installed WEBCARDLX interface;USB, DB9 and EPO cabling;Mounting hardware for 4 post rack enclosures;Instruction manual”,”value”:”SU1000RTXL2Ua with pre-installed WEBCARDLX interface;USB, DB9 and EPO cabling;Mounting hardware for 4 post rack enclosures;Instruction manual”},{“name”:”UPS Applications”,”normalizedValue”:”Mission Critical Applications”,”value”:”Mission Critical Applications”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.