Description
[{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”1,000 VA”,”rank”:4,”value”:”1000VA”},{“name”:”Mounting”,”normalizedValue”:”Tower”,”rank”:5,”value”:”Tower”},{“name”:”Wattage”,”normalizedValue”:”700 W”,”rank”:6,”value”:”700 W”},{“name”:”Input Voltage”,”normalizedValue”:”110V AC”,”rank”:7,”value”:”110V AC”},{“name”:”Output Voltage”,”normalizedValue”:”120V AC”,”rank”:8,”value”:”120V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”24 min/8 min”,”rank”:9,”value”:”24 min/8 min”},{“name”:”Outlet Type”,”normalizedValue”:”(6) 5-15R”,”rank”:10,”value”:”(6) 5-15R”},{“name”:”Number of Outlets”,”normalizedValue”:”6″,”rank”:12,”value”:”6″},{“name”:”Width”,”normalizedValue”:”7-1/2 in”,”value”:”7.5 in”},{“name”:”Transfer Time”,”normalizedValue”:”2-4 milliseconds”,”value”:”2-4 milliseconds”},{“name”:”Depth”,”normalizedValue”:”9.3 in”,”value”:”9.3 in”},{“name”:”Height”,”normalizedValue”:”12.8 in”,”value”:”12.8 in”},{“name”:”Battery Type”,”normalizedValue”:”Lead Acid”,”value”:”Valve Regulated Lead Acid (VRLA)”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 128 and 143V are reduced by 9%”,”value”:”Input voltages between 128 and 143V are reduced by 9%”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.91″,”value”:”0.91″},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”12.8 x 7.5 x 9.2″,”value”:”12.8 x 7.5 x 9.2″},{“name”:”Output Receptacles”,”normalizedValue”:”5-15R”,”value”:”(6) 5-15R”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”510″,”value”:”510″},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 96 and 107V are boosted by 10%”,”value”:”Input voltages between 96 and 107V are boosted by 10%”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Output Isolation Transformer”,”normalizedValue”:”Professional grade load isolation transformer”,”value”:”Professional grade load isolation transformer”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Input voltages between 85 and 95V are boosted by 20%”,”value”:”Input voltages between 85 and 95V are boosted by 20%”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 4.5 hours from 10% to 90%”,”value”:”Less than 4.5 hours from 10% to 90%”},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Insertion Loss”,”normalizedValue”:”65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500 Khz”,”value”:”65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500 Khz”},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”UPS Input Connection Type”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”325″,”value”:”325″},{“name”:”Expandable Runtime”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”24 min”,”value”:”24 min. (350w)”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-18%, +8%”,”value”:”-18%, +8%”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Surge Voltage Attenuation”,”normalizedValue”:”N-G 2000:1, L-G 240:1, L-N 100:1″,”value”:”N-G 2000:1, L-G 240:1, L-N 100:1″},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”1,000″,”value”:”1000″},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Surge Voltage Withstand Capability”,”normalizedValue”:”ANSI/IEEE C62.41 Categories A \u0026 B 6KV/200/500 amp 100Khz Ringwave and category B BiWave”,”value”:”ANSI/IEEE C62.41 Categories A \u0026 B 6KV/200/500 amp 100Khz Ringwave and category B BiWave”},{“name”:”Communications Cable”,”normalizedValue”:”USB cable included”,”value”:”USB cable included”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”7.6 A”,”value”:”7.6A”},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Sine wave”,”value”:”Sine wave”},{“name”:”Communications Interface”,”normalizedValue”:”USB”,”value”:”USB”},{“name”:”Power Factor”,”normalizedValue”:”0.7″,”value”:”0.7″},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”81″,”value”:”81″},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”191″,”value”:”191″},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”Hot-Swap PDU options”,”normalizedValue”:”PDUB15 (2U / 8 5-15R outlets)”,”value”:”PDUB15 (2U / 8 5-15R outlets)”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPS™s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPS™s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC53″,”value”:”RBC53″},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”234″,”value”:”234″},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 85 to 143″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 85 to 143″},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”143″,”value”:”143″},{“name”:”UPS Housing Material”,”normalizedValue”:”PVC”,”value”:”PVC”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”Wallmount (UPSWM – tower mounting kit)”,”value”:”Wallmount (UPSWM – tower mounting kit)”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”8 min”,”value”:”8 min. (700w)”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Frequency Compatibility”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Nominal Voltage Details”,”normalizedValue”:”115v nominal output in battery mode”,”value”:”115v nominal output in battery mode”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”700″,”value”:”700″},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”LED Indicators”,”normalizedValue”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”,”value”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure and low-battery conditions”,”value”:”Audible alarm indicates power-failure and low-battery conditions”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”36″,”value”:”36″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr”,”value”:”4 Hour”},{“name”:”Package Contents”,”normalizedValue”:”OmniSmart OMNI1000ISO 1000VA Tower UPS, OMNI1000ISO UPS System, USB cable, Owner’s manual with warranty information”,”value”:”OmniSmart OMNI1000ISO 1000VA Tower UPS, OMNI1000ISO UPS System, USB cable, Owner’s manual with warranty information”},{“name”:”Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Certifications \u0026 Standards”,”normalizedValue”:”UL1778 (USA), CSA C22.2 No. 107.3 (Canada), Class A (Emissions), NOM (Mexico)”,”value”:”UL1778 (USA), CSA C22.2 No. 107.3 (Canada), Class A (Emissions), NOM (Mexico)”},{“name”:”Backup/Run Time (Half Load)”,”normalizedValue”:”24 min”,”value”:”24 Minute”},{“name”:”Backup/Run Time (Full Load)”,”normalizedValue”:”8 Minute”,”value”:”8 Minute”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”Additional Information”,”normalizedValue”:”Ideal for providing a continuous clean grounding reference, voltage regulation and backup power for sensitive POS, networking and home-theater applications.”,”value”:”Ideal for providing a continuous clean grounding reference, voltage regulation and backup power for sensitive POS, networking and home-theater applications.”},{“name”:”Product Line”,”normalizedValue”:”OmniSmart”,”value”:”OmniSmart”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Name”,”normalizedValue”:”OmniSmart OMNI1000ISO 1000VA Tower UPS”,”value”:”OmniSmart OMNI1000ISO 1000VA Tower UPS”},{“name”:”Load Capacity”,”normalizedValue”:”1000 VA/700 W”,”value”:”1000 VA/700 W”},{“name”:”Plug/Connector Type”,”normalizedValue”:”NEMA 5-15P”,”value”:”NEMA 5-15P”},{“name”:”Product Type”,”normalizedValue”:”Line-interactive UPS”,”value”:”Line-interactive UPS”},{“name”:”Receptacle Detail”,”normalizedValue”:”6 x NEMA 5-15R”,”value”:”6 x NEMA 5-15R”},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”6561 ft. (2000 m) above sea level”,”value”:”6561 ft. (2000 m) above sea level”},{“name”:”UPS Applications”,”normalizedValue”:”High-End Desktop/Small Network; Retail/Point of Sale; Hospitality”,”value”:”High-End Desktop/Small Network; Retail/Point of Sale; Hospitality”},{“name”:”Runtime Half Load (min.)”,”normalizedValue”:”24 min”,”value”:”24 min. (350W)”},{“name”:”Output Capacity Details”,”normalizedValue”:”5.8A @ 120V. 125% @ 10 minutes 110% +/- 10% @ 5 seconds”,”value”:”5.8A @ 120V. 125% @ 10 minutes 110% +/- 10% @ 5 seconds”},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); NOM (Mexico); UL 1778″,”value”:”CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.91″,”value”:”0.91″},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class A (USA)”,”value”:”FCC Part 15 Class A (USA)”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”1,000″,”value”:”1000″},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”700″,”value”:”700″},{“name”:”Package Includes”,”normalizedValue”:”OMNI1000ISO UPS System;USB cable;Instruction manual”,”value”:”OMNI1000ISO UPS System;USB cable;Instruction manual”},{“name”:”Runtime Full Load (min.)”,”normalizedValue”:”8 min”,”value”:”8 min. (700W)”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.”,”value”:”Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.”},{“name”:”Unit Dimensions (hwd / in.)”,”normalizedValue”:”12.75 x 7.5 x 9.25″,”value”:”12.750 x 7.500 x 9.250″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.