Smart Online 60Kva Modular, Scalable 3-Phase, On-Line

$30729,99

Out of stock

SKU: GRG9551826 Category:

Description

[{“name”:”UPS Type”,”normalizedValue”:”On-Line”,”rank”:3,”value”:”On-Line”},{“name”:”Transfer Time”,”normalizedValue”:”No transfer time (0 ms.) in online, double-conversion mode; Less than 20 ms. transfer time in economy mode”,”value”:”No transfer time (0 ms.) in online, double-conversion mode; Less than 20 ms. transfer time in economy mode”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Maintains continuous output in online mode, without using battery power, during overvoltages to 478V (Ph-Ph), reducing output to within 1% of selected 380/220V, 400/230V, 415/240V nominal output voltage”,”value”:”Maintains continuous output in online mode, without using battery power, during overvoltages to 478V (Ph-Ph), reducing output to within 1% of selected 380/220V, 400/230V, 415/240V nominal output voltage”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”User selectable charging current of 1A to 8A (2A factory setting); Recharge rate is dependent on number of external battery packs connected and the selected charge current setting”,”value”:”User selectable charging current of 1A to 8A (2A factory setting); Recharge rate is dependent on number of external battery packs connected and the selected charge current setting”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Maintains continuous output in online mode, without using battery power, during brownout/undervoltage conditions to 305V (Ph-Ph) at full load and to 208V (Ph-Ph) at 70% output load or less, increasing output to within 1% of selected 380/220V, 400/230V, 415/240V nominal output voltage”,”value”:”Maintains continuous output in online mode, without using battery power, during brownout/undervoltage conditions to 305V (Ph-Ph) at full load and to 208V (Ph-Ph) at 70% output load or less, increasing output to within 1% of selected 380/220V, 400/230V, 415/240V nominal output voltage”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”±240VDC”,”value”:”±240VDC”},{“name”:”Communications Interface”,”normalizedValue”:”DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface”,”value”:”DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface”},{“name”:”Power Factor (Input)”,”normalizedValue”:”Greater than 0.99 (full load)”,”value”:”Greater than 0.99 (full load)”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”60″,”value”:”60″},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”2,010″,”value”:”2010″},{“name”:”Nominal Voltage Details”,”normalizedValue”:”Output THD full resistive load: \u003c1.5%; Output THD non-linear load: \u003c4%; Max DC offset:±50mV; Max Phase angle deviation: 2°; Max Voltage unbalance deviation: 1%; Output short-circuit protection included”,”value”:”Output THD full resistive load: \u003c1.5%; Output THD non-linear load: \u003c4%; Max DC offset:±50mV; Max Phase angle deviation: 2°; Max Voltage unbalance deviation: 1%; Output short-circuit protection included”},{“name”:”Switches”,”normalizedValue”:”Front panel buttons include ESC (menu escape), UP/LEFT (menu up / left), DOWN/RIGHT (menu down / right), ENTER (confirm selection), HOME (return to home screen) and POWER (on/off power control); Also includes Manual Bypass switch”,”value”:”Front panel buttons include ESC (menu escape), UP/LEFT (menu up / left), DOWN/RIGHT (menu down / right), ENTER (confirm selection), HOME (return to home screen) and POWER (on/off power control); Also includes Manual Bypass switch”},{“name”:”SNMP Compatibility”,”normalizedValue”:”Includes pre-installed WEBCARDLX network interface card”,”value”:”Includes pre-installed WEBCARDLX network interface card”},{“name”:”Input Phase”,”normalizedValue”:”3-Phase”,”value”:”3-Phase”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Hot swappable batteries”,”value”:”Automatic inverter bypass; Hot swappable batteries”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Auto-selectable, user adjustable”,”value”:”Auto-selectable, user adjustable”},{“name”:”UPS Input Connection Type”,”normalizedValue”:”Hardwire”,”value”:”Hardwire”},{“name”:”Modular Upgrade Options”,”normalizedValue”:”Includes 2 SVX30PM 30kVA power modules. Up to 6 additional SVX30PM 30kVA power modules can be added for additional capacity or N+1 availability; Add 1 SVX30PM for 90kVA capacity (or 60kVA with N+1 redundancy); Add 2 SVX30PM for 120kVA capacity (or 90kVA with N+1 redundancy); Add 3 SVX30PM for 150kVA capacity (or 120kVA with N+1 redundancy); Add 4 SVX30PM for 180kVA capacity (or 150kVA with N+1 redundancy); Add 5 SVX30PM for 210kVA capacity (or 180kVA with N+1 redundancy); Add 6 SVX30PM for 210kVA total capacity with N+1 redundancy”,”value”:”Includes 2 SVX30PM 30kVA power modules. Up to 6 additional SVX30PM 30kVA power modules can be added for additional capacity or N+1 availability; Add 1 SVX30PM for 90kVA capacity (or 60kVA with N+1 redundancy); Add 2 SVX30PM for 120kVA capacity (or 90kVA with N+1 redundancy); Add 3 SVX30PM for 150kVA capacity (or 120kVA with N+1 redundancy); Add 4 SVX30PM for 180kVA capacity (or 150kVA with N+1 redundancy); Add 5 SVX30PM for 210kVA capacity (or 180kVA with N+1 redundancy); Add 6 SVX30PM for 210kVA total capacity with N+1 redundancy”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, MODBUSCARDSV, RELAYCARDSV”,”value”:”WEBCARDLX ; MODBUSCARDSV ; RELAYCARDSV”},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Output Frequency Regulation”,”normalizedValue”:”ONLINE MODE: Output frequency is±0.05Hz of input frequency when input is within±4Hz* of the configured 50/60Hz output setting; Output frequency is±0.05Hz the configured 50/60Hz output setting when input is outside±4Hz* of the configured 50/60Hz output setting; BATTERY MODE: Output frequency is±0.1Hz of the configured 50/60Hz output setting; FREQUENCY CONVERTER MODE: Output frequency is±0.1Hz of the configured 50/60Hz output setting; ECONOMY MODE: Output frequency equals input frequency up to±4Hz* of the configured 50/60Hz output setting (UPS switches to Online mode if frequency goes outside of this range); BYPASS MODE: Output frequency equals input frequency up to±4Hz* of the configured 50/60Hz output setting (switches to STANDBY mode if frequency goes outside of this range). *The TRACKING RANGE is factory set to±4Hz and is user adjustable to±1Hz,±2Hz or±4Hz; The selected TRACKING RANGE setting controls frequency output tolerances as described above in Online, Economy and Bypass modes”,”value”:”ONLINE MODE: Output frequency is±0.05Hz of input frequency when input is within±4Hz* of the configured 50/60Hz output setting; Output frequency is±0.05Hz the configured 50/60Hz output setting when input is outside±4Hz* of the configured 50/60Hz output setting; BATTERY MODE: Output frequency is±0.1Hz of the configured 50/60Hz output setting; FREQUENCY CONVERTER MODE: Output frequency is±0.1Hz of the configured 50/60Hz output setting; ECONOMY MODE: Output frequency equals input frequency up to±4Hz* of the configured 50/60Hz output setting (UPS switches to Online mode if frequency goes outside of this range); BYPASS MODE: Output frequency equals input frequency up to±4Hz* of the configured 50/60Hz output setting (switches to STANDBY mode if frequency goes outside of this range). *The TRACKING RANGE is factory set to±4Hz and is user adjustable to±1Hz,±2Hz or±4Hz; The selected TRACKING RANGE setting controls frequency output tolerances as described above in Online, Economy and Bypass modes”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”60″,”value”:”60″},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”60,000″,”value”:”60000″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”10,851″,”value”:”10851″},{“name”:”AC Suppression Joule Rating”,”normalizedValue”:”2,496″,”value”:”2496″},{“name”:”Audible Noise”,”normalizedValue”:”Less than 73 DBA front-side, 1m”,”value”:”Less than 73 DBA front-side, 1m”},{“name”:”Storage Temperature Range”,”normalizedValue”:”-15° to +60°C”,”value”:”-15° to +60°C (+5° to +140°F)”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fans”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, replaceable batteries”,”value”:”Hot-swappable, replaceable batteries”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye”,”value”:”220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”79.13 x 23.62 x 43.3″,”value”:”79.13 x 23.62 x 43.3″},{“name”:”Output Circuit Breakers”,”normalizedValue”:”400A 3 pole magnetic breaker”,”value”:”400A 3 pole magnetic breaker”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”Maintains continuous operation without using battery power during brownout/undervoltage conditions to 305V (Ph-Ph) Full load or 208V (Ph-Ph) 70% load or less; Below the low transfer voltage point, output is maintained utilizing reserve battery power”,”value”:”Maintains continuous operation without using battery power during brownout/undervoltage conditions to 305V (Ph-Ph) Full load or 208V (Ph-Ph) 70% load or less; Below the low transfer voltage point, output is maintained utilizing reserve battery power”},{“name”:”Operating Elevation (m)”,”normalizedValue”:”Up to 1000m (At elevations over 1000m, output de-rates by 1% per 100m)”,”value”:”Up to 1000m (At elevations over 1000m, output de-rates by 1% per 100m)”},{“name”:”Output Capacity Details”,”normalizedValue”:”OVERLOAD CAPABILITY: Supports 105-110% load for 1 hour, 111-125% load for 10 minutes, 126-150% for 1 minute and Over 150% for 200ms before switching to Bypass; Online operation resumes when load is reduced to 100% or less”,”value”:”OVERLOAD CAPABILITY: Supports 105-110% load for 1 hour, 111-125% load for 10 minutes, 126-150% for 1 minute and Over 150% for 200ms before switching to Bypass; Online operation resumes when load is reduced to 100% or less”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”SVX60KL 60kVA Configuration: 110A; Maximum 210kVA Large Chassis Configuration: 385A; 40A maximum inrush current”,”value”:”SVX60KL 60kVA Configuration: 110A; Maximum 210kVA Large Chassis Configuration: 385A; 40A maximum inrush current”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Includes pre-installed Tripp Lite WEBCARDLX network interface”,”value”:”Includes pre-installed Tripp Lite WEBCARDLX network interface”},{“name”:”Operating Temperature Range”,”normalizedValue”:”0° to +40°C (+32° to +104°F); De-rates to 90% capacity at 35°C / 95°F and 80% capacity at 40°C / 104°F”,”value”:”0° to +40°C (+32° to +104°F); De-rates to 90% capacity at 35°C / 95°F and 80% capacity at 40°C / 104°F”},{“name”:”Expandable Runtime Description”,”normalizedValue”:”External battery pack wiring is contractor supplied”,”value”:”External battery pack wiring is contractor supplied”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”THDi”,”normalizedValue”:”Less than 3%”,”value”:”Less than 3% (full linear load)”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”Maintains continuous operation without using battery power during overvoltages to 478V (Ph-Ph), reducing output within 1% of nominal; Above this point, output is maintained utilizing reserve battery power”,”value”:”Maintains continuous operation without using battery power during overvoltages to 478V (Ph-Ph), reducing output within 1% of nominal; Above this point, output is maintained utilizing reserve battery power”},{“name”:”Output Voltage Regulation”,”normalizedValue”:”ONLINE, FREQUENCY CONVERSION, BATTERY MODE: 220/230/240V±1% typical (balanced load);±2% typical (unbalanced load); ECONOMY MODE: 220/230/240V±15V; BYPASS MODE: +15% (default, adjustable to +10%, +15% or +20%), -20% (default, adjustable to -10%, -20%, -30%)”,”value”:”ONLINE, FREQUENCY CONVERSION, BATTERY MODE: 220/230/240V±1% typical (balanced load);±2% typical (unbalanced load); ECONOMY MODE: 220/230/240V±15V; BYPASS MODE: +15% (default, adjustable to +10%, +15% or +20%), -20% (default, adjustable to -10%, -20%, -30%)”},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.99″,”value”:”0.99″},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.95″,”value”:”0.95″},{“name”:”AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Output Amp Capacity”,”normalizedValue”:”91A (220/380V); 87A (230/400V); 83A (240/415V)”,”value”:”91A (220/380V); 87A (230/400V); 83A (240/415V)”},{“name”:”UPS Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”LED Indicators”,”normalizedValue”:”Front panel LED indicators represent INPUT (green), BYPASS (amber), INVERTER (green), BATTERY (red) and ALARM (red)”,”value”:”Front panel LED indicators represent INPUT (green), BYPASS (amber), INVERTER (green), BATTERY (red) and ALARM (red)”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”60,000″,”value”:”60000″},{“name”:”UPS Certification Details”,”normalizedValue”:”Agency standards IEC 62040-1:2008+A1:2013; EMI Approvals EN62040-2, 2006 (Category C3); Vibration and Shock: SS-EN 60068-2-64″,”value”:”Agency standards IEC 62040-1:2008+A1:2013; EMI Approvals EN62040-2, 2006 (Category C3); Vibration and Shock: SS-EN 60068-2-64″},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Audible alarms can be muted using on-screen prompts”,”value”:”Audible alarms can be muted using on-screen prompts”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”145mm front panel LCD display with directional scroll and select buttons offers complete operating status display, plus setting and selection options for all UPS functions”,”value”:”145mm front panel LCD display with directional scroll and select buttons offers complete operating status display, plus setting and selection options for all UPS functions”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”MAIN and ALTERNATE AC inputs are each protected by 400A 3 pole magnetic breakers”,”value”:”MAIN and ALTERNATE AC inputs are each protected by 400A 3 pole magnetic breakers”},{“name”:”UPS Certifications”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,402″,”value”:”1402″},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”Batteries sold separate; Runtime is dependent on battery pack quantity and load level”,”value”:”Batteries sold separate; Runtime is dependent on battery pack quantity and load level”},{“name”:”Nominal Input Voltage Description”,”normalizedValue”:”Set of two hardwire input connections enables 3-Phase Wye, 4 wire (3P, N, G) inputs from two separate power sources”,”value”:”Set of two hardwire input connections enables 3-Phase Wye, 4 wire (3P, N, G) inputs from two separate power sources”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Supports extended runtime with optional external battery packs; 100A 3 pole 250VDC breaker recommended for external battery”,”value”:”Supports extended runtime with optional external battery packs; 100A 3 pole 250VDC breaker recommended for external battery”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye”,”value”:”220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye”},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”600″,”value”:”600″},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”1,100″,”value”:”1100″},{“name”:”AC Suppression Joule Rating Details”,”normalizedValue”:”2496 joules (Ph-Ph), 2496 joules (Ph-N), 1872 joules (N-E)”,”value”:”2496 joules (Ph-Ph), 2496 joules (Ph-N), 1872 joules (N-E)”},{“name”:”Communications Cable”,”normalizedValue”:”DB9 cabling included”,”value”:”DB9 cabling included”},{“name”:”Power Factor”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Output Receptacles”,”normalizedValue”:”Hardwire”,”value”:”Hardwire”},{“name”:”Audible Alarm”,”normalizedValue”:”Unique audible alarms for POWER ON / POWER OFF (alarm sounds for 2 seconds), BATTERY MODE (alarm sounds every 2 seconds), LOW BATTERY (alarm sounds every 0.5 seconds), UPS ALARM (alarm sounds every 1 second), UPS FAULT (continuous alarm)”,”value”:”Unique audible alarms for POWER ON / POWER OFF (alarm sounds for 2 seconds), BATTERY MODE (alarm sounds every 2 seconds), LOW BATTERY (alarm sounds every 0.5 seconds), UPS ALARM (alarm sounds every 1 second), UPS FAULT (continuous alarm)”},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Input Frequency”,”normalizedValue”:”40 to 70Hz (online mode); 50/60Hz Auto-selectable”,”value”:”40 to 70Hz (online mode); 50/60Hz Auto-selectable”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Online, double-conversion power conditioning”,”value”:”Online, double-conversion power conditioning”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Frequency Compatibility”,”normalizedValue”:”50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion”,”value”:”50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Unknown”,”value”:”Unknown”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Smart Online 60Kva Modular, Scalable 3-Phase, On-Line”