Single phase relay, Harmony Solid State Relays, 75A, panel mount, zero voltage switching, thermal pad, input 90 to 280V AC, output 48 to 660V AC

$74,39

This Harmony SSP solid state panel mount single-phase relay is rated 75A, is controlled with a 90V to 280V AC input, has a rated load voltage of 48V to 660V AC with zero voltage switching, ideal for resistive loads. It has a visual indicator showing the status of its input and a alarm output enabling a quick response to unexpected events. It also has a test button for easy debugging, testing and commissioning. It is also silent and reliable thanks to the absence of moving contacts.

9999 in stock

SKU: GRG5956603 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Ssr1p Panel Mnt,75A@660VAC,ZC,90-280VDC”,”rank”:1,”value”:”Ssr1p Panel Mnt,75A@660VAC,ZC,90-280VDC”},{“name”:”Electrical Phase”,”normalizedValue”:”1″,”rank”:2,”value”:”1″},{“name”:”Electrical Connection”,”normalizedValue”:”Screw Terminal”,”rank”:3,”value”:”screw terminals”},{“name”:”Mounting Style”,”normalizedValue”:”Panel”,”rank”:4,”value”:”panel mount”},{“name”:”Switch Component Type”,”normalizedValue”:”SCR”,”rank”:5,”value”:”SCR”},{“name”:”Standards”,”normalizedValue”:”UL 508 || CSA C22.2 No 14-13 || EN/IEC 60950-1 || EN/IEC 62314″,”value”:”UL 508 || CSA C22.2 No 14-13 || EN/IEC 60950-1 || EN/IEC 62314″},{“name”:”Maximum Horse Power Rating”,”normalizedValue”:”1.5 hp 120 V AC || 3 hp 240 V AC || 7.5 hp 480 V AC”,”value”:”1.5 hp 120 V AC || 3 hp 240 V AC || 7.5 hp 480 V AC”},{“name”:”Maximum Leakage Current”,”normalizedValue”:”1 mA off-state”,”value”:”1 mA off-state”},{“name”:”Surge Current”,”normalizedValue”:”1000 A 16.6 ms”,”value”:”1000 A 16.6 ms”},{“name”:”Solid State Output Type”,”normalizedValue”:”SCR output || zero voltage switching”,”value”:”SCR output || zero voltage switching”},{“name”:”Dielectric Strength”,”normalizedValue”:”4 kV AC for input/output || 4 kV AC for input or output to case”,”value”:”4 kV AC for input/output || 4 kV AC for input or output to case”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw terminals 0.2 to 3.3 mm², AWG 24 to AWG 12) with cable end input || screw terminals 0.5 to 5.26 mm², AWG 20 to AWG 10) with cable end output || screw terminals 0.2 to 3.3 mm², AWG 24 to AWG 12) without cable end input || screw terminals 0.5 to 8.26 mm², AWG 20 to AWG 8) without cable end output || forked type tag connectors 9.2 x 4 mm input || ring lugs 9.2 x 4 mm input || forked type tag connectors 11.7 x 4.5 mm output || ring lugs 11.7 x 4.5 mm output”,”value”:”screw terminals 0.2 to 3.3 mm², AWG 24 to AWG 12) with cable end input || screw terminals 0.5 to 5.26 mm², AWG 20 to AWG 10) with cable end output || screw terminals 0.2 to 3.3 mm², AWG 24 to AWG 12) without cable end input || screw terminals 0.5 to 8.26 mm², AWG 20 to AWG 8) without cable end output || forked type tag connectors 9.2 x 4 mm input || ring lugs 9.2 x 4 mm input || forked type tag connectors 11.7 x 4.5 mm output || ring lugs 11.7 x 4.5 mm output”},{“name”:”Input Current Limits”,”normalizedValue”:”5 to 10 mA”,”value”:”5-10 mA”},{“name”:”Product Certifications”,”normalizedValue”:”EAC || CE || UL || CSA”,”value”:”EAC || CE || UL || CSA”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Tightening Torque”,”normalizedValue”:”1.5 to 1.7 N.m for input || 2 to 2.2 N.m for output”,”value”:”1.5 to 1.7 N.m for input || 2 to 2.2 N.m for output”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”90 V AC turn-on”,”value”:”90 V AC turn-on”},{“name”:”Absolute Maximum Voltage”,”normalizedValue”:”1,200 V”,”value”:”1200 V”},{“name”:”Thermal Impedance”,”normalizedValue”:”0.48°C-in²/W @ 25 psi”,”value”:”0.48°C-in²/W at 25 psi”},{“name”:”Load Current”,”normalizedValue”:”0.15 to 75 A”,”value”:”0.15-75 A”},{“name”:”Marking”,”normalizedValue”:”UL || EAC || CSA || CE”,”value”:”UL || EAC || CSA || CE”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV output to case || 6 kV input to output”,”value”:”6 kV output to case || 6 kV input to output”},{“name”:”Device Short Name”,”normalizedValue”:”SSP1″,”value”:”SSP1″},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-125°C”,”value”:”-40-125°C”},{“name”:”Cos Phi”,”normalizedValue”:”0.5-0.5 (with maximum load)”,”value”:”0.5-0.5 (with maximum load)”},{“name”:”Response Time”,”normalizedValue”:”30 ms (turn-off) || 25 ms (turn-on)”,”value”:”30 ms (turn-off) || 25 ms (turn-on)”},{“name”:”Dv/Dt”,”normalizedValue”:”500 V/µs”,”value”:”500 V/µs off-state at maximum voltage”},{“name”:”Protection Device Type”,”normalizedValue”:”type 1 – 50 A miniature circuit breaker B || type 2 – 40 A miniature circuit breaker B”,”value”:”type 1 – 50 A miniature circuit breaker (MCB) B || type 2 – 40 A miniature circuit breaker (MCB) B”},{“name”:”Maximum Voltage Drop”,”normalizedValue”:”<1.15 V on-state","value":"<1.15 V on-state"},{"name":"Pollution Degree","normalizedValue":"2","value":"2"},{"name":"Thermal Resitance","normalizedValue":"junction to case","value":"0.3°C/W junction to case"},{"name":"Local Signalling","normalizedValue":"LED, green input","value":"LED, green input"},{"name":"Capacitance Unbalance","normalizedValue":"8 pF (for input/output)","value":"8 pF for input/output"},{"name":"[Uc] Control Circuit Voltage","normalizedValue":"90 to 280 V AC","value":"90 to 280 V AC"},{"name":"Provided Equipment","normalizedValue":"thermal pad","value":"thermal pad"},{"name":"Overvoltage Category","normalizedValue":"III","value":"III"},{"name":"Maximum I²T For Fusing","normalizedValue":"4150 A².s for 8.33 ms at 60 Hz || 4555 A².s for 10 ms at 50 Hz","value":"4150 A².s for 8.33 ms at 60 Hz || 4555 A².s for 10 ms at 50 Hz"},{"name":"Insulation Resistance","normalizedValue":"1000 MOhm at 500 V DC","value":"1000 MOhm at 500 V DC"},{"name":"Maximum Switching Voltage","normalizedValue":"10 V AC turn-off","value":"10 V AC turn-off"},{"name":"Output switching mode","normalizedValue":"zero voltage switching","value":"zero voltage switching"},{"name":"Ambient Air Temperature For Operation","normalizedValue":"-40-80°C","value":"-40-80°C"},{"name":"Range of Product","normalizedValue":"Harmony Solid State Relays","value":"Harmony Solid State Relays"},{"name":"Device Presentation","normalizedValue":"complete product","value":"complete product"},{"name":"Output Voltage Range","normalizedValue":"48 to 660 V","value":"48 to 660 V"},{"name":"Maximum Output Current with Heat Sink","normalizedValue":"75 A","value":"75 A"},{"name":"Country of Origin (subject to change)","normalizedValue":"Mexico","value":"Mexico"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews

There are no reviews yet.

Be the first to review “Single phase relay, Harmony Solid State Relays, 75A, panel mount, zero voltage switching, thermal pad, input 90 to 280V AC, output 48 to 660V AC”