Single phase relay, Harmony Solid State Relays, 25A, panel mount, zero voltage switching, thermal pad, input 90 to 280V AC, output 24 to 300V AC

$32,29

This Harmony SSP solid state panel mount single-phase relay is rated 25A, is controlled with a 90V to 280V AC input, has a rated load voltage of 24V to 300V AC with zero voltage switching, ideal for resistive loads. It has a visual indicator showing the status of its input and a alarm output enabling a quick response to unexpected events. It also has a test button for easy debugging, testing and commissioning. It is also silent and reliable thanks to the absence of moving contacts.

9999 in stock

SKU: GRG5956612 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Ssr1p Panel Mnt,25A@300VAC,ZC,90-280VDC”,”rank”:1,”value”:”Ssr1p Panel Mnt,25A@300VAC,ZC,90-280VDC”},{“name”:”Electrical Phase”,”normalizedValue”:”1″,”rank”:2,”value”:”1″},{“name”:”Electrical Connection”,”normalizedValue”:”Screw”,”rank”:3,”value”:”screw”},{“name”:”Mounting Style”,”normalizedValue”:”Panel”,”rank”:4,”value”:”Panel”},{“name”:”Switch Component Type”,”normalizedValue”:”SCR”,”rank”:5,”value”:”SCR”},{“name”:”Standards”,”normalizedValue”:”CSA C22.2 No 14-13 || EN/IEC 62314 || EN/IEC 60950-1 || UL 508″,”value”:”CSA C22.2 No 14-13 || EN/IEC 62314 || EN/IEC 60950-1 || UL 508″},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV output to case || 6 kV input to output”,”value”:”6 kV output to case || 6 kV input to output”},{“name”:”Thermal Impedance”,”normalizedValue”:”0.48°C-in²/W @ 25 psi”,”value”:”0.48°C-in²/W at 25 psi”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”90 V AC turn-on”,”value”:”90 V AC turn-on”},{“name”:”Provided Equipment”,”normalizedValue”:”thermal pad”,”value”:”thermal pad”},{“name”:”Product Certifications”,”normalizedValue”:”CSA || UL || CE || EAC”,”value”:”CSA || UL || CE || EAC”},{“name”:”Dv/Dt”,”normalizedValue”:”500 V/µs”,”value”:”500 V/µs off-state at maximum voltage”},{“name”:”Response Time”,”normalizedValue”:”30 ms (turn-off) || 25 ms (turn-on)”,”value”:”30 ms (turn-off) || 25 ms (turn-on)”},{“name”:”Solid State Output Type”,”normalizedValue”:”SCR output || zero voltage switching”,”value”:”SCR output || zero voltage switching”},{“name”:”Marking”,”normalizedValue”:”UL || CSA || EAC || CE”,”value”:”UL || CSA || EAC || CE”},{“name”:”Insulation Resistance”,”normalizedValue”:”1000 MOhm at 500 V DC”,”value”:”1000 MOhm at 500 V DC”},{“name”:”Maximum Leakage Current”,”normalizedValue”:”1 mA off-state”,”value”:”1 mA off-state”},{“name”:”Local Signalling”,”normalizedValue”:”LED, green input”,”value”:”LED, green input”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Maximum Switching Voltage”,”normalizedValue”:”10 V AC turn-off”,”value”:”10 V AC turn-off”},{“name”:”Input Current Limits”,”normalizedValue”:”5 to 10 mA”,”value”:”5-10 mA”},{“name”:”Surge Current”,”normalizedValue”:”250 A 16.6 ms”,”value”:”250 A 16.6 ms”},{“name”:”Tightening Torque”,”normalizedValue”:”1.5 to 1.7 N.m for input || 2 to 2.2 N.m for output”,”value”:”1.5 to 1.7 N.m for input || 2 to 2.2 N.m for output”},{“name”:”Overvoltage Category”,”normalizedValue”:”III”,”value”:”III”},{“name”:”Load Current”,”normalizedValue”:”0.15 to 25 A”,”value”:”0.15-25 A”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-125°C”,”value”:”-40-125°C”},{“name”:”Thermal Resitance”,”normalizedValue”:”junction to case”,”value”:”0.8°C/W junction to case”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-40-80°C”,”value”:”-40-80°C”},{“name”:”Capacitance Unbalance”,”normalizedValue”:”8 pF (for input/output)”,”value”:”8 pF for input/output”},{“name”:”Cos Phi”,”normalizedValue”:”0.5-0.5 (with maximum load)”,”value”:”0.5-0.5 (with maximum load)”},{“name”:”Absolute Maximum Voltage”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Dielectric Strength”,”normalizedValue”:”4 kV AC for input/output || 4 kV AC for input or output to case”,”value”:”4 kV AC for input/output || 4 kV AC for input or output to case”},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”90 to 280 V AC”,”value”:”90 to 280 V AC”},{“name”:”Maximum I²T For Fusing”,”normalizedValue”:”259 A².s for 8.33 ms at 60 Hz || 285 A².s for 10 ms at 50 Hz”,”value”:”259 A².s for 8.33 ms at 60 Hz || 285 A².s for 10 ms at 50 Hz”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw terminals 0.2 to 3.3 mm², AWG 24 to AWG 12) with cable end input || screw terminals 0.5 to 5.26 mm², AWG 20 to AWG 10) with cable end output || screw terminals 0.2 to 3.3 mm², AWG 24 to AWG 12) without cable end input || screw terminals 0.5 to 8.26 mm², AWG 20 to AWG 8) without cable end output || forked type tag connectors 9.2 x 4 mm input || ring lugs 9.2 x 4 mm input || forked type tag connectors 11.7 x 4.5 mm output || ring lugs 11.7 x 4.5 mm output”,”value”:”screw terminals 0.2 to 3.3 mm², AWG 24 to AWG 12) with cable end input || screw terminals 0.5 to 5.26 mm², AWG 20 to AWG 10) with cable end output || screw terminals 0.2 to 3.3 mm², AWG 24 to AWG 12) without cable end input || screw terminals 0.5 to 8.26 mm², AWG 20 to AWG 8) without cable end output || forked type tag connectors 9.2 x 4 mm input || ring lugs 9.2 x 4 mm input || forked type tag connectors 11.7 x 4.5 mm output || ring lugs 11.7 x 4.5 mm output”},{“name”:”Pollution Degree”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Output switching mode”,”normalizedValue”:”zero voltage switching”,”value”:”zero voltage switching”},{“name”:”Device Short Name”,”normalizedValue”:”SSP1″,”value”:”SSP1″},{“name”:”Maximum Horse Power Rating”,”normalizedValue”:”0.5 hp 120 V AC || 1 hp 240 V AC”,”value”:”0.5 hp 120 V AC || 1 hp 240 V AC”},{“name”:”Maximum Voltage Drop”,”normalizedValue”:”<1.15 V on-state","value":"<1.15 V on-state"},{"name":"Protection Device Type","normalizedValue":"type 1 - 25 A miniature circuit breaker B || type 2 - 20 A miniature circuit breaker B","value":"type 1 - 25 A miniature circuit breaker (MCB) B || type 2 - 20 A miniature circuit breaker (MCB) B"},{"name":"Device Presentation","normalizedValue":"complete product","value":"complete product"},{"name":"Range of Product","normalizedValue":"Harmony Solid State Relays","value":"Harmony Solid State Relays"},{"name":"Output Voltage Range","normalizedValue":"24 to 300 V AC","value":"24 to 300 V AC"},{"name":"Maximum Output Current with Heat Sink","normalizedValue":"25 A","value":"25 A"},{"name":"Country of Origin (subject to change)","normalizedValue":"Mexico","value":"Mexico"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews

There are no reviews yet.

Be the first to review “Single phase relay, Harmony Solid State Relays, 25A, panel mount, zero voltage switching, thermal pad, input 90 to 280V AC, output 24 to 300V AC”