Description
[{“name”:”Item”,”normalizedValue”:”Ssr1p Panel Mnt,50A@660VAC,ZC,90-280VDC”,”rank”:14,”value”:”Ssr1p Panel Mnt,50A@660VAC,ZC,90-280VDC”},{“name”:”Standards”,”normalizedValue”:”IEC 60950-1, CSA C22.2 No 14-13, UL 508, IEC 62314″,”value”:”IEC 60950-1, CSA C22.2 No 14-13, UL 508, IEC 62314″},{“name”:”Phase”,”normalizedValue”:”1 phase”,”value”:”1 phase”},{“name”:”Insulation Resistance”,”normalizedValue”:”1000 MOhm at 500 V DC”,”value”:”1000 MOhm at 500 V DC”},{“name”:”Thermal Resitance”,”normalizedValue”:”junction to case”,”value”:”0.45°C/W junction to case”},{“name”:”Maximum Leakage Current”,”normalizedValue”:”1 mA off-state”,”value”:”1 mA off-state”},{“name”:”Ip Degree of Protection”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Maximum I²T For Fusing”,”normalizedValue”:”1770 A².s for 10 ms at 50 Hz, 1629 A².s for 8.33 ms at 60 Hz”,”value”:”1770 A².s for 10 ms at 50 Hz, 1629 A².s for 8.33 ms at 60 Hz”},{“name”:”Product or Component Type”,”normalizedValue”:”solid state relay up to 50 A”,”value”:”solid state relay up to 50 A”},{“name”:”Absolute Maximum Voltage”,”normalizedValue”:”1,200 V”,”value”:”1200 V”},{“name”:”Maximum Switching Voltage”,”normalizedValue”:”10 V AC turn-off”,”value”:”10 V AC turn-off”},{“name”:”Load Current”,”normalizedValue”:”0.15 to 50 A”,”value”:”0.15-50 A”},{“name”:”Pollution Degree”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”90 V AC turn-on”,”value”:”90 V AC turn-on”},{“name”:”Input Current Limits”,”normalizedValue”:”5 to 10 mA”,”value”:”5-10 mA”},{“name”:”Marking”,”normalizedValue”:”EAC, UL, CSA, CE”,”value”:”EAC, UL, CSA, CE”},{“name”:”Dielectric Strength”,”normalizedValue”:”4 kV AC for input/output, 4 kV AC for input or output to case”,”value”:”4 kV AC for input/output, 4 kV AC for input or output to case”},{“name”:”Output Switching Mode”,”normalizedValue”:”switching”,”value”:”zero voltage switching”},{“name”:”Device Short Name”,”normalizedValue”:”SSP1″,”value”:”SSP1″},{“name”:”Capacitance Unbalance”,”normalizedValue”:”8 pF (for input/output)”,”value”:”8 pF for input/output”},{“name”:”Maximum Voltage Drop”,”normalizedValue”:”\u003c1.15 V on-state”,”value”:”\u003c1.15 V on-state”},{“name”:”Device Presentation”,”normalizedValue”:”complete product”,”value”:”complete product”},{“name”:”Local Signalling”,”normalizedValue”:”LED, green input”,”value”:”LED, green input”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw terminals 0.2…3.3 mm², AWG 24…AWG 12) with cable end input, screw terminals 0.5…5.26 mm², AWG 20…AWG 10) with cable end output, screw terminals 0.2…3.3 mm², AWG 24…AWG 12) without cable end input, screw terminals 0.5…8.26 mm², AWG 20…AWG 8) without cable end output, forked type tag connectors 9.2 x 4 mm input, ring lugs 9.2 x 4 mm input, forked type tag connectors 11.7 x 4.5 mm output, ring lugs 11.7 x 4.5 mm output”,”value”:”screw terminals 0.2…3.3 mm², AWG 24…AWG 12) with cable end input, screw terminals 0.5…5.26 mm², AWG 20…AWG 10) with cable end output, screw terminals 0.2…3.3 mm², AWG 24…AWG 12) without cable end input, screw terminals 0.5…8.26 mm², AWG 20…AWG 8) without cable end output, forked type tag connectors 9.2 x 4 mm input, ring lugs 9.2 x 4 mm input, forked type tag connectors 11.7 x 4.5 mm output, ring lugs 11.7 x 4.5 mm output”},{“name”:”Dv/Dt”,”normalizedValue”:”500 V/µs”,”value”:”500 V/µs off-state at maximum voltage”},{“name”:”Maximum Horse Power Rating”,”normalizedValue”:”0.75 hp 120 V AC, 2 hp 240 V AC, 5 hp 480 V AC”,”value”:”0.75 hp 120 V AC, 2 hp 240 V AC, 5 hp 480 V AC”},{“name”:”Response Time”,”normalizedValue”:”30 msec, 25 msec”,”value”:”30 ms (turn-off), 25 ms (turn-on)”},{“name”:”Provided Equipment”,”normalizedValue”:”thermal pad”,”value”:”thermal pad”},{“name”:”Line Rated Current”,”normalizedValue”:”50 A”,”value”:”50 A”},{“name”:”Overvoltage Category”,”normalizedValue”:”III”,”value”:”III”},{“name”:”Surge Current”,”normalizedValue”:”625 A 16.6 ms”,”value”:”625 A 16.6 ms”},{“name”:”Tightening Torque”,”normalizedValue”:”1.5…1.7 N.m for input, 2…2.2 N.m for output”,”value”:”1.5…1.7 N.m for input, 2…2.2 N.m for output”},{“name”:”Solid State Output Type”,”normalizedValue”:”SCR output, zero voltage switching”,”value”:”SCR output, zero voltage switching”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV output to case, 6 kV input to output”,”value”:”6 kV output to case, 6 kV input to output”},{“name”:”Protection Device Type”,”normalizedValue”:”type 1 – 40 A miniature circuit breaker B, type 2 – 32 A miniature circuit breaker B”,”value”:”type 1 – 40 A miniature circuit breaker (MCB) B, type 2 – 32 A miniature circuit breaker (MCB) B”},{“name”:”Cos Phi”,”normalizedValue”:”0.5-0.5 (with maximum load)”,”value”:”0.5-0.5 (with maximum load)”},{“name”:”Range of Product”,”normalizedValue”:”Harmony Solid State Relays”,”value”:”Harmony Solid State Relays”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-125°C”,”value”:”-40-125°C”},{“name”:”Thermal Impedance”,”normalizedValue”:”0.48°C-in²/W @ 25 psi”,”value”:”0.48°C-in²/W at 25 psi”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-40-80°C”,”value”:”-40-80°C”},{“name”:”Product Certifications”,”normalizedValue”:”CE || UL || CSA || EAC”,”value”:”CE || UL || CSA || EAC”},{“name”:”Output Voltage”,”normalizedValue”:”48 to 660 V AC”,”value”:”48 to 660 V AC”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”90 to 280 V AC”,”value”:”90 to 280 V AC”},{“name”:”Product Or Component Type”,”normalizedValue”:”solid state relay up to 50 A”,”value”:”solid state relay up to 50 A”},{“name”:”Output switching mode”,”normalizedValue”:”zero voltage switching”,”value”:”zero voltage switching”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.