Single function relay, Harmony Timer Relays, 5A, 4CO, 0.1s.100h, on delay, 24V DC

$67,99

Timer,250VAC 3A,Rexl +options

9999 in stock

SKU: GRG7123844 Category:

Description

[{“name”:”Standards”,”normalizedValue”:”EN/IEC 60601-2 || EN 61000-6-2 || 73/23/EEC || EN/IEC 61812-1 || 93/68/EEC || EN/IEC 60601-1 || 89/336/EEC || EN 50081-2″,”value”:”EN/IEC 60601-2 || EN 61000-6-2 || 73/23/EEC || EN/IEC 61812-1 || 93/68/EEC || EN/IEC 60601-1 || 89/336/EEC || EN 50081-2″},{“name”:”Item”,”normalizedValue”:”Timer,250VAC 3A,Rexl +options”,”value”:”Timer,250VAC 3A,Rexl +options”},{“name”:”Width”,”normalizedValue”:”21 mm”,”value”:”21 mm”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP50 conforming to IEC 60529″,”value”:”IP50 conforming to IEC 60529″},{“name”:”Maximum Switching Capacity”,”normalizedValue”:”4 x 5 A”,”value”:”4 x 5 A”},{“name”:”Power Consumption In W”,”normalizedValue”:”1.2 W”,”value”:”1.2 W”},{“name”:”Relative Humidity”,”normalizedValue”:”95-95 %, without condensation IEC 60068-2-6″,”value”:”95-95 % without condensation IEC 60068-2-6″},{“name”:”Time Delay Type”,”normalizedValue”:”power on-delay”,”value”:”power on-delay”},{“name”:”Repeat Accuracy”,”normalizedValue”:”+/- 0.5 %”,”value”:”+/- 0.5 %”},{“name”:”Time Delay Range”,”normalizedValue”:”10…100 h || 6…60 s || 6…60 min || 1…10 s || 1…10 h || 1…10 min || 0.1…1 s”,”value”:”10…100 h || 6…60 s || 6…60 min || 1…10 s || 1…10 h || 1…10 min || 0.1…1 s”},{“name”:”Immunity To Radioelectric Fields”,”normalizedValue”:”10 V 0.15…80 MHz)EN/IEC 61000-4-6 level 3″,”value”:”10 V 0.15…80 MHz)EN/IEC 61000-4-6 level 3″},{“name”:”Contacts Material”,”normalizedValue”:”cadmium free”,”value”:”cadmium free”},{“name”:”Dielectric Strength”,”normalizedValue”:”2 kV 1 mA/1 minute 50 Hz EN/IEC 60601-1 || 2 kV 1 mA/1 minute 50 Hz EN/IEC 61812-1″,”value”:”2 kV 1 mA/1 minute 50 Hz EN/IEC 60601-1 || 2 kV 1 mA/1 minute 50 Hz EN/IEC 61812-1″},{“name”:”Line Rated Current”,”normalizedValue”:”5 A”,”value”:”5 A AC”},{“name”:”Resistance To Electromagnetic Fields”,”normalizedValue”:”10 V/m EN/IEC 61000-4-3 level 3″,”value”:”10 V/m EN/IEC 61000-4-3 level 3″},{“name”:”Product Or Component Type”,”normalizedValue”:”single function relay”,”value”:”single function relay”},{“name”:”[Us] Rated Supply Voltage”,”normalizedValue”:”24 V DC”,”value”:”24 V DC”},{“name”:”Discrete Output Type”,”normalizedValue”:”relay”,”value”:”relay”},{“name”:”Disturbance Radiated/Conducted”,”normalizedValue”:”class B EN 55022 (EN 55011 group 1)”,”value”:”class B EN 55022 (EN 55011 group 1)”},{“name”:”Temperature Drift”,”normalizedValue”:”°, 0.05 % C”,”value”:”0.05 %/°C”},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”5 msec”,”value”:”5 ms”},{“name”:”Setting Accuracy Of Time Delay”,”normalizedValue”:”10 % at full scale 25°C EN/IEC 61812-1″,”value”:”10 % at full scale 25°C EN/IEC 61812-1″},{“name”:”Contacts Type And Composition”,”normalizedValue”:”O, 4 C”,”value”:”4 C/O”},{“name”:”Reset Time”,”normalizedValue”:”250 ms after time delay, on de-energisation || 50 ms during time delay, on de-energisation”,”value”:”250 ms after time delay, on de-energisation || 50 ms during time delay, on de-energisation”},{“name”:”Fixing Mode”,”normalizedValue”:”plug-in socket)”,”value”:”plug-in socket)”},{“name”:”Temporary Permissible Current”,”normalizedValue”:”10 A < 10 s","value":"10 A < 10 s"},{"name":"Creepage Distance","normalizedValue":"4 kV/3 IEC 60664-1","value":"4 kV/3 IEC 60664-1"},{"name":"Voltage Drift","normalizedValue":"+/- 0.2 %/V","value":"+/- 0.2 %/V"},{"name":"Immunity To Voltage Dips","normalizedValue":">= 95 % / 1 s EN/IEC 61000-4-11 || 30 % / 10 ms EN/IEC 61000-4-11 || 60 % / 100 ms EN/IEC 61000-4-11″,”value”:”>= 95 % / 1 s EN/IEC 61000-4-11 || 30 % / 10 ms EN/IEC 61000-4-11 || 60 % / 100 ms EN/IEC 61000-4-11″},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”250 V IEC 255 Group C || 250 V VDE 0010″,”value”:”250 V IEC 255 Group C || 250 V VDE 0010″},{“name”:”Output Overvoltage Protection”,”normalizedValue”:”2 J”,”value”:”2 J”},{“name”:”Electrical Durability”,”normalizedValue”:”100000 cycles 250 V AC resistive”,”value”:”100000 cycles 250 V AC resistive”},{“name”:”Resistance To Fast Transients”,”normalizedValue”:”2 kV EN/IEC 61000-4-4 level 3″,”value”:”2 kV EN/IEC 61000-4-4 level 3″},{“name”:”Surge Withstand”,”normalizedValue”:”2 kV EN/IEC 61000-4-5 level 3″,”value”:”2 kV EN/IEC 61000-4-5 level 3″},{“name”:”Component Name”,”normalizedValue”:”REXL”,”value”:”REXL”},{“name”:”Local Signalling”,”normalizedValue”:”for output in operation 1 LED (red) || for power ON 1 LED (yellow)”,”value”:”for output in operation 1 LED (red) || for power ON 1 LED (yellow)”},{“name”:”Minimum Switching Current”,”normalizedValue”:”100 mA”,”value”:”100 mA”},{“name”:”Vibration Resistance”,”normalizedValue”:”0.35 mm 10-55 Hz)IEC 60068-2-6″,”value”:”0.35 mm 10-55 Hz)IEC 60068-2-6″},{“name”:”Resistance To Electrostatic Discharge”,”normalizedValue”:”6 kV in contact EN/IEC 61000-4-2 level 3 || 8 kV in air EN/IEC 61000-4-2 level 3″,”value”:”6 kV in contact EN/IEC 61000-4-2 level 3 || 8 kV in air EN/IEC 61000-4-2 level 3″},{“name”:”Voltage Range”,”normalizedValue”:”0.9…1.1 Us”,”value”:”0.9…1.1 Us”},{“name”:”Mechanical Durability”,”normalizedValue”:”10000000 cycles”,”value”:”10000000 cycles”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-60°C”,”value”:”-20-60°C”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Product Certifications”,”normalizedValue”:”UL || cUL”,”value”:”UL || cUL”},{“name”:”Number of Functions”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Range of Product”,”normalizedValue”:”Harmony Timer Relays”,”value”:”Harmony Timer Relays”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Indonesia”,”value”:”Indonesia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Single function relay, Harmony Timer Relays, 5A, 4CO, 0.1s.100h, on delay, 24V DC”