Description
[{“name”:”Width”,”normalizedValue”:”4.7 in”,”value”:”4.7 in”},{“name”:”Depth”,”normalizedValue”:”3.1 in”,”value”:”3.1 in”},{“name”:”Height”,”normalizedValue”:”1 in”,”value”:”1 in”},{“name”:”Number of Total Expansion Slots”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Number of SFP Slots”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Weight (Approximate)”,”normalizedValue”:”10.58 oz”,”value”:”10.58 oz”},{“name”:”Expansion Slot Type”,”normalizedValue”:”SFP”,”value”:”SFP”},{“name”:”Network Technology”,”normalizedValue”:”1000Base-X”,”value”:”1000Base-X”},{“name”:”Product Type”,”normalizedValue”:”Transceiver/Media Converter”,”value”:”Transceiver/Media Converter”},{“name”:”Input voltage”,”normalizedValue”:”12 V DC”,”value”:”12 V DC”},{“name”:”Ethernet Technology”,”normalizedValue”:”Gigabit Ethernet”,”value”:”Gigabit Ethernet”},{“name”:”Certifications & Standards”,”normalizedValue”:”Immunity: EN55024 Laser Safety: Dependent on SFPs used. SFPs that meet Class 1 Laser safety requirements per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11 are recommended for use with this product. Emissions: FCC Part 15 Class A,EN55022 Class A,CISPR 22 Class A,EN61000-3-2 Electrical Safety: UL 60950-1,EN60950,CE”,”value”:”Immunity: EN55024 Laser Safety: Dependent on SFPs used. SFPs that meet Class 1 Laser safety requirements per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11 are recommended for use with this product. Emissions: FCC Part 15 Class A,EN55022 Class A,CISPR 22 Class A,EN61000-3-2 Electrical Safety: UL 60950-1,EN60950,CE”},{“name”:”Form Factor”,”normalizedValue”:”Desktop, Rack-mountable, Wall Mountable, Rail-mountable”,”value”:”Desktop, Rack-mountable, Wall Mountable, Rail-mountable”},{“name”:”Product Name”,”normalizedValue”:”S-4GPT-DSFP-XT Fiber Mode Converter”,”value”:”S-4GPT-DSFP-XT Fiber Mode Converter”},{“name”:”Environmentally Friendly”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Immunity”,”normalizedValue”:”EN55024″,”value”:”EN55024″},{“name”:”Heat Output ( BTU/HR )”,”normalizedValue”:”13.65″,”value”:”13.65″},{“name”:”Current”,”normalizedValue”:”325mA @ 12VDC”,”value”:”325mA @ 12VDC”},{“name”:”LK1″,”normalizedValue”:”LED is ON when a signal is detected on LK1. LED is OFF when there is no signal.”,”value”:”LED is ON when a signal is detected on LK1. LED is OFF when there is no signal.”},{“name”:”Rate Select”,”normalizedValue”:”This enables rate selection when using dual-rate capable SFPs. If the \”Multi-Speed SFP\” select switch is in the \”Disabled\” position, this switch is ignored; High Speed – UP ( default ); Low Speed – DOWN”,”value”:”This enables rate selection when using dual-rate capable SFPs. If the \”Multi-Speed SFP\” select switch is in the \”Disabled\” position, this switch is ignored; High Speed – UP ( default ); Low Speed – DOWN”},{“name”:”Operating temperature”,”normalizedValue”:”-40° C to 75° C (-40° F to 167° F)”,”value”:”-40° C to 75° C (-40° F to 167° F)”},{“name”:”Power”,”normalizedValue”:”This green LED is turned on when power is applied to the media converter. This LED is off when there is no power supplied; A Blinking LED will indicate that a hardware error has been detected.”,”value”:”This green LED is turned on when power is applied to the media converter. This LED is off when there is no power supplied; A Blinking LED will indicate that a hardware error has been detected.”},{“name”:”Fiber Fault Alert”,”normalizedValue”:”If the media converter module detects a loss of fiber, it will immediately notify the fiber link partner that an error condition exists; Disabled ( Default ).The Media Converter will not monitor for fiber fault.”,”value”:”If the media converter module detects a loss of fiber, it will immediately notify the fiber link partner that an error condition exists; Disabled ( Default ).The Media Converter will not monitor for fiber fault.”},{“name”:”Operating Humidity”,”normalizedValue”:”5% to 90% non-condensing”,”value”:”5% to 90% non-condensing”},{“name”:”LK2″,”normalizedValue”:”LED is ON when a signal is detected on LK2. LED is OFF when there is no signal.”,”value”:”LED is ON when a signal is detected on LK2. LED is OFF when there is no signal.”},{“name”:”Operating Altitude”,”normalizedValue”:”Up to 3,048 meters (10,000 feet)”,”value”:”Up to 3,048 meters (10,000 feet)”},{“name”:”Power Consumption”,”normalizedValue”:”4 watts”,”value”:”4 watts”},{“name”:”Power Connector”,”normalizedValue”:”2 pin terminal block”,”value”:”2-pin terminal block”},{“name”:”Storage Humidity”,”normalizedValue”:”5% to 95% non-condensing”,”value”:”5% to 95% non-condensing”},{“name”:”Input Supply Voltage”,”normalizedValue”:”6 – 30 vDC, unregulated ( 12 vDC Nominal ). Regulated power adapter is not included”,”value”:”6 – 30 vDC, unregulated ( 12 vDC Nominal ). Regulated power adapter is not included”},{“name”:”SFPs”,”normalizedValue”:”SFP line rates up to 4.25Gbps are supported. The SFPs occupying each slot in the media converter however must be operating at the same speed; SFP power level 1 and 2 are supported.”,”value”:”SFP line rates up to 4.25Gbps are supported. The SFPs occupying each slot in the media converter however must be operating at the same speed; SFP power level 1 and 2 are supported.”},{“name”:”Multi-speed SFP”,”normalizedValue”:”When enabled, identifies that the SFPs inserted are MSA complaint SFPs that have a multi-rate capability; When disable ( Default ), no action is performed in this context.”,”value”:”When enabled, identifies that the SFPs inserted are MSA complaint SFPs that have a multi-rate capability; When disable ( Default ), no action is performed in this context.”},{“name”:”Electrical Safety”,”normalizedValue”:”UL 60950-1″,”value”:”UL 60950-1″},{“name”:”MTBF”,”normalizedValue”:”902294″,”value”:”902294″},{“name”:”Laser Safety”,”normalizedValue”:”Dependent on SFPs used. SFPs that meet Class 1 Laser safety requirements per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11 are recommended for use with this product.”,”value”:”Dependent on SFPs used. SFPs that meet Class 1 Laser safety requirements per IEC-60825 FDA/CDRH standards and comply with 21CFR1040.10 and 21CFR1040.11 are recommended for use with this product.”},{“name”:”Dimensions”,”normalizedValue”:”120 x 80 x 26 mm, 4.7 x 3.1 x 1.0 inches”,”value”:”120 x 80 x 26 mm, 4.7 x 3.1 x 1.0 inches”},{“name”:”Storage temperature”,”normalizedValue”:”minimum range of -40° C to 85° C (-40° F to 185° F)”,”value”:”minimum range of -40° C to 85° C (-40° F to 185° F)”},{“name”:”Emissions”,”normalizedValue”:”FCC Part 15 Class A, EN55022 Class A”,”value”:”FCC Part 15 Class A, EN55022 Class A”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Canada”,”value”:”Canada”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.