S-110Pp-M2St2 Media Converter

$778,99

S-110PP-M2ST2 – 10/100Base-TX Media and Rate Converter with PoE+ (PoEP) Power Sourcing: 10/100Base-TX (RJ-45) [100 m/328 ft.] to 100BASE-FX 1310nm multimode (ST) [2 km/1.2 miles] includes AC Power Adapter – USA Power Cord

9999 in stock

SKU: GRG4399704 Category:

Description

[{“name”:”Height”,”normalizedValue”:”1 in”,”value”:”1 in”},{“name”:”Width”,”normalizedValue”:”3.1 in”,”value”:”3.1 in”},{“name”:”Depth”,”normalizedValue”:”5 in”,”value”:”5 in”},{“name”:”Size”,”normalizedValue”:”Maximum frame size of 2048 bytes”,”value”:”Maximum frame size of 2048 bytes”},{“name”:”Network Technology”,”normalizedValue”:”100Base-FX, 10/100Base-TX”,”value”:”100Base-FX, 10/100Base-TX”},{“name”:”Package Contents”,”normalizedValue”:”S-110PP-M2ST2 Media Converter, Power Strain Relief Strap, AC Adatper”,”value”:”S-110PP-M2ST2 Media Converter, Power Strain Relief Strap, AC Adatper”},{“name”:”Maximum Distance Supported”,”normalizedValue”:”1.24 mi”,”value”:”1.24 Mile”},{“name”:”Form Factor”,”normalizedValue”:”Rack-mountable, Rail-mountable, Wall Mountable”,”value”:”Rack-mountable, Rail-mountable, Wall Mountable”},{“name”:”ST Port Type”,”normalizedValue”:”Duplex”,”value”:”Duplex”},{“name”:”Weight (Approximate)”,”normalizedValue”:”11.20 oz”,”value”:”11.20 oz”},{“name”:”Product Type”,”normalizedValue”:”Transceiver/Media Converter”,”value”:”Transceiver/Media Converter”},{“name”:”Network (RJ-45)”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Environmentally Friendly”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Number of Network (RJ-45) Ports”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Total Number of Ports”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Product Name”,”normalizedValue”:”S-110PP-M2ST2 Media Converter”,”value”:”S-110PP-M2ST2 Media Converter”},{“name”:”Number of ST Ports”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Heat Output ( BTU/HR )”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Remote Loopback”,”normalizedValue”:”The media converter can perform a loopback on the 100Base-X fiber interface; Disabled (Default – Up); Enabled- The 100Base-X receiver is looped to the 100Base-X transmitter. The 100Base-TX transmitter is taken off the interface.”,”value”:”The media converter can perform a loopback on the 100Base-X fiber interface; Disabled (Default – Up); Enabled- The 100Base-X receiver is looped to the 100Base-X transmitter. The 100Base-TX transmitter is taken off the interface.”},{“name”:”Universal AC/DC adapter”,”normalizedValue”:”100-240v AC, regulated 48vDC adapter included for PoE; 100-240v AC, regulated 56vDC adapter included for PoE+”,”value”:”100-240v AC, regulated 48vDC adapter included for PoE; 100-240v AC, regulated 56vDC adapter included for PoE+”},{“name”:”10/100 Speed”,”normalizedValue”:”This green LED is operational only when power is applied. The LED is green when the speed of the copper ethernet port is running at 100 Mbps. The LED is off when in 10 Mbps.”,”value”:”This green LED is operational only when power is applied. The LED is green when the speed of the copper ethernet port is running at 100 Mbps. The LED is off when in 10 Mbps.”},{“name”:”Duplex Copper (internal strap)”,”normalizedValue”:”Full (Default); Half”,”value”:”Full (Default); Half”},{“name”:”10/100Base-TX”,”normalizedValue”:”RJ45 connector; 2 pair CAT5, EIA/TIA 568A/B or better cable for 10/100.”,”value”:”RJ45 connector; 2 pair CAT5, EIA/TIA 568A/B or better cable for 10/100.”},{“name”:”Storage temperature”,”normalizedValue”:”minimum range of -25 C to 70 C (-13 F to 158 F)”,”value”:”minimum range of -25 C to 70 C (-13 F to 158 F)”},{“name”:”PSE Power”,”normalizedValue”:”When enabled (UP), the media converter will perform a Power Sourcing Equipment (PSE) function as per IEEE802.3af or 802.3at standards (relevant model); Default is \”enabled\””,”value”:”When enabled (UP), the media converter will perform a Power Sourcing Equipment (PSE) function as per IEEE802.3af or 802.3at standards (relevant model); Default is \”enabled\””},{“name”:”PSE Status”,”normalizedValue”:”This LED will signify the status of the PSE function. Using multi-color and blinking the unit will show the following status for the PSE; GREEN – Solid: The PSE has successfully detected a compliant PD and is applying power over the UTP (for legacy pin out simply show active power when applied); YELLOW – Solid: The PSE is not active. This means the PSE has been configured to provide power, but the PD is : Not connected; Has not detected a compliant PD and is not applying power; PSE has turned off power for Reset function; OFF – PSE function switch disabled; RED – Blinking: Error Conditions; Capacitance too High – 1 blink; Resistance too Low or short circuit – 2 blinks; Resistance too high or open circuit – 3 blinks”,”value”:”This LED will signify the status of the PSE function. Using multi-color and blinking the unit will show the following status for the PSE; GREEN – Solid: The PSE has successfully detected a compliant PD and is applying power over the UTP (for legacy pin out simply show active power when applied); YELLOW – Solid: The PSE is not active. This means the PSE has been configured to provide power, but the PD is : Not connected; Has not detected a compliant PD and is not applying power; PSE has turned off power for Reset function; OFF – PSE function switch disabled; RED – Blinking: Error Conditions; Capacitance too High – 1 blink; Resistance too Low or short circuit – 2 blinks; Resistance too high or open circuit – 3 blinks”},{“name”:”Small Form Factor Pluggable ( SFP ) slot”,”normalizedValue”:”SFP slot models: Empty slot for 100Base-XSFP modules supplied by Perle,Ciscoor other manufacturers of MSA compliant SFPs; Hot insertion and removable ( hot swappable ).”,”value”:”SFP slot models: Empty slot for 100Base-XSFP modules supplied by Perle,Ciscoor other manufacturers of MSA compliant SFPs; Hot insertion and removable ( hot swappable ).”},{“name”:”Immunity”,”normalizedValue”:”EN55024″,”value”:”EN55024″},{“name”:”Operating Humidity”,”normalizedValue”:”5% to 90% non-condensing”,”value”:”5% to 90% non-condensing”},{“name”:”Electrical Safety”,”normalizedValue”:”UL 60950-1″,”value”:”UL 60950-1″},{“name”:”Power Over Ethernet (PSE)”,”normalizedValue”:”PoE models: maximum to 15.4 watts supplied to port; PoE+ models: up to 30 watts supplied to port”,”value”:”PoE models: maximum to 15.4 watts supplied to port; PoE+ models: up to 30 watts supplied to port”},{“name”:”Emissions”,”normalizedValue”:”FCC Part 15 Class A, EN55022 Class A”,”value”:”FCC Part 15 Class A, EN55022 Class A”},{“name”:”Operating temperature”,”normalizedValue”:”0 C to 50 C (32 F to 122 F)”,”value”:”0 C to 50 C (32 F to 122 F)”},{“name”:”Copper link on / Receive activity ( LKC 1/2 )”,”normalizedValue”:”This green LED is operational only when power is applied. The LED will blink along with transmit/receive data on the 10/100/1000 UTP port; If a loss of link on the copper port results in a Link Passthrough condition to the fiber port, this LED will blink at a rate of once every 2 seconds until the condition is cleared.”,”value”:”This green LED is operational only when power is applied. The LED will blink along with transmit/receive data on the 10/100/1000 UTP port; If a loss of link on the copper port results in a Link Passthrough condition to the fiber port, this LED will blink at a rate of once every 2 seconds until the condition is cleared.”},{“name”:”PoE Options”,”normalizedValue”:”Alternative A ( power on pins 1,2 and 3,6 ); Alternative B ( power on pins 4,5 and 7,8 ); Legacy PoE ( IE VoIP phones and wireless access points ) – ( reverse polarity on pins 4,5 and 7,8 ); Legacy large capacitor detect ( pins 4,5 and 7,8 )”,”value”:”Alternative A ( power on pins 1,2 and 3,6 ); Alternative B ( power on pins 4,5 and 7,8 ); Legacy PoE ( IE VoIP phones and wireless access points ) – ( reverse polarity on pins 4,5 and 7,8 ); Legacy large capacitor detect ( pins 4,5 and 7,8 )”},{“name”:”Link Pass Through”,”normalizedValue”:”Disabled (Default)- The 100Base-TX and the 100Base-FX fiber interface operate independently. Far-End Fault indication on the 100Base-FX fiber interface has no effect on the 100Base-TX interface; Enabled- When the state of the receiver is changed on the 100Base-TX interface it is reflected on the 100Base-FX fiber transmitter. When the state of the receiver on the 100Base-FX interface is changed it is reflected on the 100Base-TX transmitter; When a Far-End Fault Indication is received on the fiber interface the 100Base-TX transmitter is turned off. When the Far-End Fault Indication is cleared the transmitter is turned back on.”,”value”:”Disabled (Default)- The 100Base-TX and the 100Base-FX fiber interface operate independently. Far-End Fault indication on the 100Base-FX fiber interface has no effect on the 100Base-TX interface; Enabled- When the state of the receiver is changed on the 100Base-TX interface it is reflected on the 100Base-FX fiber transmitter. When the state of the receiver on the 100Base-FX interface is changed it is reflected on the 100Base-TX transmitter; When a Far-End Fault Indication is received on the fiber interface the 100Base-TX transmitter is turned off. When the Far-End Fault Indication is cleared the transmitter is turned back on.”},{“name”:”Operating Altitude”,”normalizedValue”:”Up to 3,048 meters (10,000 feet)”,”value”:”Up to 3,048 meters (10,000 feet)”},{“name”:”Dimensions”,”normalizedValue”:”120 x 80 x 26 mm, 4.7 x 3.1 x 1.0 inches”,”value”:”120 x 80 x 26 mm, 4.7 x 3.1 x 1.0 inches”},{“name”:”Storage Humidity”,”normalizedValue”:”5% to 95% non-condensing”,”value”:”5% to 95% non-condensing”},{“name”:”PD Power Reset”,”normalizedValue”:”This is a technique to perform a power reset on a PD device attached; When enabled ( down ), the media converter will upon loss of link on any fiber port, turn off PSE output power to the PD device for 2 seconds then turn the power back on. The power remains on until any fiber link transitions from up to down again; With Passthrough enabled, a loss of link on the fiber resulting from a loss of link on the copper, a PD Power Reset will occur and the copper link will continue to reflect the state of the fiber link; When PD Power Reset disabled, loss of fiber link has no effect on PSE power to the PD device.”,”value”:”This is a technique to perform a power reset on a PD device attached; When enabled ( down ), the media converter will upon loss of link on any fiber port, turn off PSE output power to the PD device for 2 seconds then turn the power back on. The power remains on until any fiber link transitions from up to down again; With Passthrough enabled, a loss of link on the fiber resulting from a loss of link on the copper, a PD Power Reset will occur and the copper link will continue to reflect the state of the fiber link; When PD Power Reset disabled, loss of fiber link has no effect on PSE power to the PD device.”},{“name”:”DC Power Requirements”,”normalizedValue”:”PoE models: 46 – 57 vDC; PoE+ models: 52 – 57 vDC”,”value”:”PoE models: 46 – 57 vDC; PoE+ models: 52 – 57 vDC”},{“name”:”Magnetic Isolation”,”normalizedValue”:”1.5kv”,”value”:”1.5kv”},{“name”:”Power Connector”,”normalizedValue”:”5.5mm x 9.5mm x 2.1mm barrel socket”,”value”:”5.5mm x 9.5mm x 2.1mm barrel socket”},{“name”:”Speed Copper (internal strap)”,”normalizedValue”:”100 (Default); 10″,”value”:”100 (Default); 10″},{“name”:”PoE Power Options ( Internal Straps )”,”normalizedValue”:”Set to Alternative A ( default ): Pins 3,6 Neg, Pins 1,2 Pos; Set to Alternative B: Pins 7,8 Neg, Pins 4,5 Pos; Set to Legacy Pre-Standard: Pins 7,8 Pos, Pins 4,5 Neg”,”value”:”Set to Alternative A ( default ): Pins 3,6 Neg, Pins 1,2 Pos; Set to Alternative B: Pins 7,8 Neg, Pins 4,5 Pos; Set to Legacy Pre-Standard: Pins 7,8 Pos, Pins 4,5 Neg”},{“name”:”Filtering”,”normalizedValue”:”1024 MAC Addresses”,”value”:”1024 MAC Addresses”},{“name”:”Buffer”,”normalizedValue”:”1,000 Kbits (frame buffer memory)”,”value”:”1000 Kbits frame buffer memory”},{“name”:”Fiber link on / Receive activity ( LKF 1/2 )”,”normalizedValue”:”This green LED is operational only when power is applied. The LED will blink along with transmit/receive data on the fiber port; If a loss of link on the copper port results in a Link Passthrough condition to the fiber port, this LED will blink at a rate of once every 2 seconds until the condition is cleared.”,”value”:”This green LED is operational only when power is applied. The LED will blink along with transmit/receive data on the fiber port; If a loss of link on the copper port results in a Link Passthrough condition to the fiber port, this LED will blink at a rate of once every 2 seconds until the condition is cleared.”},{“name”:”Power ( PWR )”,”normalizedValue”:”This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink slowly when either fiber port is in Loopback test mode. The LED will blink quickly if there is a hardware failure where the reason code can be identified through a various blinking cycles.”,”value”:”This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink slowly when either fiber port is in Loopback test mode. The LED will blink quickly if there is a hardware failure where the reason code can be identified through a various blinking cycles.”},{“name”:”Auto-Negotiation (802.3u)”,”normalizedValue”:”Enabled (Default)- The media converter uses 802.3u Auto-negotiation on the 100Base-TX interface. It is set to advertise full duplex; Disabled- The media converter sets the port according to the position of the speed and duplex switches.”,”value”:”Enabled (Default)- The media converter uses 802.3u Auto-negotiation on the 100Base-TX interface. It is set to advertise full duplex; Disabled- The media converter sets the port according to the position of the speed and duplex switches.”},{“name”:”Fixed Fiber”,”normalizedValue”:”Multimode dual ST Media Converters; Single strand fiber ( Simplex ) – SC; LC – obtained by inserting an SFP ( LC ) in an SFP slot model”,”value”:”Multimode dual ST Media Converters; Single strand fiber ( Simplex ) – SC; LC – obtained by inserting an SFP ( LC ) in an SFP slot model”},{“name”:”Auto-MDIX (Internal Strap)”,”normalizedValue”:”If Auto-Negotiation (802.3u) is enabled, the media converter determines the current cable pinout to use on the copper interface. If Auto-Negotiation (802.3u) is disabled the Media converter will use the RX Energy method on the copper interface to set the port MDI or MDIX whichever is appropriate; Enabled (Default) – Either a straight-through or crossover type cable can be used to connect the media converter to the device on the other end of the cable; Disabled – If the partner device on the other end of the cable does not have the Auto-MDIX feature a specific cable, either a straight-through or crossover will be required to ensure that the media converter’s transmitter and the partner devices transmitter are connected to the others receiver. The Media converter’s 100Base-TX port is configured as MDI-X with this switch setting.”,”value”:”If Auto-Negotiation (802.3u) is enabled, the media converter determines the current cable pinout to use on the copper interface. If Auto-Negotiation (802.3u) is disabled the Media converter will use the RX Energy method on the copper interface to set the port MDI or MDIX whichever is appropriate; Enabled (Default) – Either a straight-through or crossover type cable can be used to connect the media converter to the device on the other end of the cable; Disabled – If the partner device on the other end of the cable does not have the Auto-MDIX feature a specific cable, either a straight-through or crossover will be required to ensure that the media converter’s transmitter and the partner devices transmitter are connected to the others receiver. The Media converter’s 100Base-TX port is configured as MDI-X with this switch setting.”},{“name”:”Power Consumption”,”normalizedValue”:”3.5 Watts”,”value”:”3.5 Watts”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Canada”,”value”:”Canada”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “S-110Pp-M2St2 Media Converter”