Relay, 24 to 240V AC/DC Coil Volts, 2 NO, Schneider Electric, Mfr#: RM35ATW5MW

$274,73

Relay, Contact Form DPDT, Contact Rating (AC) 5 A @ 250V, Contact Rating (DC) 5 A @ 250V, Current Rating 5 A, Flat Pin Width Not Applicable, Input Voltage 24 to 240V AC/DC, Monitored Parameters Overtemperature, Phase Failure, Phase Sequence, Undertemperature, Number of Pins 12, Restart Auto, Restart Time Delay 1.5 sec, IP Rating IP30, Mounting Style DIN Rail, Body Depth 2.83 in, Body Height 3.54 in, Body Width 1.38 in, Electrical Operating Durability 100,000

Out of stock

SKU: GRG2056077 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Relay”,”rank”:1,”value”:”Relay”},{“name”:”Coil Volts”,”normalizedValue”:”24 to 240V AC/DC”,”rank”:2,”value”:”24 to 240V AC/DC”},{“name”:”Contact Form – Relay”,”normalizedValue”:”2 NO”,”rank”:7,”value”:”2 NO”},{“name”:”Mounting – Relay”,”normalizedValue”:”DIN Rail”,”rank”:8,”value”:”DIN Rail”},{“name”:”Power Consumption – Relay”,”normalizedValue”:”3.5 VA”,”rank”:10,”value”:”3.5 VA”},{“name”:”Contact Material”,”normalizedValue”:”Cadmium Free”,”rank”:11,”value”:”Cadmium Free”},{“name”:”Body Height – Relay”,”normalizedValue”:”3.54 in”,”rank”:12,”value”:”3.54 in”},{“name”:”Body Width – Relay”,”normalizedValue”:”1.38 in”,”rank”:13,”value”:”1.38 in”},{“name”:”Body Depth – Relay”,”normalizedValue”:”2.83 in”,”rank”:14,”value”:”2.83 in”},{“name”:”Overall Height – Relay”,”normalizedValue”:”3.54 in”,”rank”:15,”value”:”3.54 in”},{“name”:”Features”,”normalizedValue”:”IP Degree of Protection: IP40; Mercury Free: Yes, Toxic Heavy Metal Free: Yes”,”rank”:16,”value”:”IP Degree of Protection: IP40; Mercury Free: Yes, Toxic Heavy Metal Free: Yes”},{“name”:”Standards”,”normalizedValue”:”C-Tick, CSA Certified, EN/IEC 60255-1, EN/IEC 61000-6-4, EU RoHS, GL, GOST, Reach Regulation, UL Listed”,”rank”:17,”value”:”C-Tick, CSA Certified, EN/IEC 60255-1, EN/IEC 61000-6-4, EU RoHS, GL, GOST, Reach Regulation, UL Listed”},{“name”:”Item – Relay”,”normalizedValue”:”Plug In Relay”,”value”:”Plug In Relay”},{“name”:”Status Indicator”,”normalizedValue”:”LED Indicator”,”value”:”LED”},{“name”:”Restart”,”normalizedValue”:”Auto”,”value”:”Auto”},{“name”:”Maximum Switching Voltage”,”normalizedValue”:”250V AC/DC”,”value”:”250V AC/DC”},{“name”:”Power Consumption”,”normalizedValue”:”1,250 VA”,”value”:”1,250 VA”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Contact Rating (DC)”,”normalizedValue”:”5 A @ 250 V”,”value”:”5 A @ 250V”},{“name”:”Body Depth”,”normalizedValue”:”2.83 in”,”value”:”2.83 in”},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail”,”value”:”DIN Rail”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Electrical Operating Durability”,”normalizedValue”:”100,000″,”value”:”100,000″},{“name”:”Housing Material”,”normalizedValue”:”Plastic”,”value”:”Plastic”},{“name”:”Number of Pins”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Current Rating”,”normalizedValue”:”5 A”,”value”:”5 A”},{“name”:”Maximum Switching Capacity”,”normalizedValue”:”1,250 VA”,”value”:”1,250 VA”},{“name”:”Overall Depth”,”normalizedValue”:”2.83 in”,”value”:”2.83 in”},{“name”:”Monitored Parameters”,”normalizedValue”:”Overtemperature, Phase Failure, Phase Sequence, Undertemperature”,”value”:”Overtemperature, Phase Failure, Phase Sequence, Undertemperature”},{“name”:”Flat Pin Width”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Mechanical Operating Durability”,”normalizedValue”:”30,000,000″,”value”:”30,000,000″},{“name”:”Body Height”,”normalizedValue”:”3.54 in”,”value”:”3.54 in”},{“name”:”Contact Form”,”normalizedValue”:”DPDT”,”value”:”DPDT”},{“name”:”Input Voltage”,”normalizedValue”:”24 to 240V AC/DC”,”value”:”24 to 240V AC/DC”},{“name”:”IP Rating”,”normalizedValue”:”IP30″,”value”:”IP30″},{“name”:”Body Width”,”normalizedValue”:”1.38 in”,”value”:”1.38 in”},{“name”:”Minimum Switching Current”,”normalizedValue”:”10 mA”,”value”:”10 mA”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Contact Rating (AC)”,”normalizedValue”:”5 A @ 250V”,”value”:”5 A @ 250V”},{“name”:”Restart Time Delay”,”normalizedValue”:”1.5 sec”,”value”:”1.5 sec”},{“name”:”Temperature Probe Type”,”normalizedValue”:”Pt 100 – 3-wire”,”value”:”Pt 100 – 3-wire”},{“name”:”Switching Power”,”normalizedValue”:”1250 VA”,”value”:”1250 VA”},{“name”:”Response Time”,”normalizedValue”:”Less than or Equal to 3.5 s + Tt (in case of temperature fault); 500 ms (in case of 3-phase fault); 500 ms (on disappearance of fault)”,”value”:”Less than or Equal to 3.5 s + Tt (in case of temperature fault); 500 ms (in case of 3-phase fault); 500 ms (on disappearance of fault)”},{“name”:”Electromagnetic Compatibility”,”normalizedValue”:”Emission standard for industrial environments IEC 61000-6-4; Emission standard for residential, commercial and light-industrial environments IEC 61000-6-3; Immunity for industrial environments NF EN/IEC 61000-6-2″,”value”:”Emission standard for industrial environments IEC 61000-6-4; Emission standard for residential, commercial and light-industrial environments IEC 61000-6-3; Immunity for industrial environments NF EN/IEC 61000-6-2″},{“name”:”Insulation Resistance”,”normalizedValue”:”Greater than 500 MOhm 500 V DC between supply and relay output IEC 60255-5; Greater than 500 MOhm 500 V DC between measurement and relay output IEC 60664-1; Greater than 1 MOhm 500 V DC between supply and measurement IEC 60255-5; Greater than 500 MOhm 500 V DC between supply and relay output IEC 60664-1; Greater than 500 MOhm 500 V DC between measurement and relay output IEC 60255-5; Greater than 1 MOhm 500 V DC between supply and measurement IEC 60664-1″,”value”:”Greater than 500 MOhm 500 V DC between supply and relay output IEC 60255-5; Greater than 500 MOhm 500 V DC between measurement and relay output IEC 60664-1; Greater than 1 MOhm 500 V DC between supply and measurement IEC 60255-5; Greater than 500 MOhm 500 V DC between supply and relay output IEC 60664-1; Greater than 500 MOhm 500 V DC between measurement and relay output IEC 60255-5; Greater than 1 MOhm 500 V DC between supply and measurement IEC 60664-1″},{“name”:”Nominal Output Current”,”normalizedValue”:”5 A”,”value”:”5 A”},{“name”:”Non-Dissipating Shock Wave”,”normalizedValue”:”4 kV”,”value”:”4 kV”},{“name”:”Vibration Resistance”,”normalizedValue”:”0.35 mm 5 to 57.6 Hz)IEC 60068-2-6/IEC 60255-21-1; 1 gn 57.6 to 150 Hz)IEC 60068-2-6/IEC 60255-21-1″,”value”:”0.35 mm 5 to 57.6 Hz)IEC 60068-2-6/IEC 60255-21-1; 1 gn 57.6 to 150 Hz)IEC 60068-2-6/IEC 60255-21-1″},{“name”:”Reset Time”,”normalizedValue”:”8 sec”,”value”:”8 s”},{“name”:”Operating Rate”,”normalizedValue”:”Less than or Equal to 360 operations/hour full load”,”value”:”Less than or Equal to 360 operations/hour full load”},{“name”:”Shock Resistance”,”normalizedValue”:”15 gn 11 ms IEC 60255-21-1″,”value”:”15 gn 11 ms IEC 60255-21-1″},{“name”:”Product Or Component Type”,”normalizedValue”:”Elevator machine room temperature control relay”,”value”:”Elevator machine room temperature control relay”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40 to 158°F”,”value”:”-40 to 158°F (-40 to 70°C)”},{“name”:”Rated Supply Voltage”,”normalizedValue”:”24 to 240 V AC/DC”,”value”:”24 to 240 V AC/DC”},{“name”:”Relay Monitored Parameters”,”normalizedValue”:”Phase sequence; Phase failure detection; Undertemperature: -1 to 11°C; Overtemperature: 34 to 46°C”,”value”:”Phase sequence; Phase failure detection; Undertemperature: -1 to 11°C; Overtemperature: 34 to 46°C”},{“name”:”Operating Voltage Tolerance”,”normalizedValue”:”- 10% + 10% Un DC; – 15% + 10% Un AC”,”value”:”- 10% + 10% Un DC; – 15% + 10% Un AC”},{“name”:”Electrical Durability”,”normalizedValue”:”100000 cycles”,”value”:”100000 cycles”},{“name”:”Delay At Power Up”,”normalizedValue”:”0.2 s”,”value”:”0.2 s”},{“name”:”Mechanical Durability”,”normalizedValue”:”30,000,000 cycle”,”value”:”30000000 cycles”},{“name”:”Tightening Torque”,”normalizedValue”:”5.31 to 8.85 lbf.in (0.6 to 1 N.m) IEC 60947-1″,”value”:”5.31 to 8.85 lbf.in (0.6 to 1 N.m) IEC 60947-1″},{“name”:”Marking”,”normalizedValue”:”CE : 73/23, CE : EMC 89/336/EEC, EEC”,”value”:”CE : EMC 89/336/EEC; CE : 73/23/EEC”},{“name”:”Supply Voltage Limits”,”normalizedValue”:”20.4 to 264 V AC; 21.6 to 264 V DC”,”value”:”20.4 to 264 V AC; 21.6 to 264 V DC”},{“name”:”IP Degree Of Protection”,”normalizedValue”:”IP20 IEC 60529 terminals; IP30 IEC 60529 casing)”,”value”:”IP20 IEC 60529 terminals; IP30 IEC 60529 casing)”},{“name”:”Overvoltage Category”,”normalizedValue”:”III IEC 60664-1″,”value”:”III IEC 60664-1″},{“name”:”Product Specific Application”,”normalizedValue”:”For elevator machine rooms and 3-phase supplies”,”value”:”For elevator machine rooms and 3-phase supplies”},{“name”:”Maximum Power Consumption in W”,”normalizedValue”:”0.6 W DC”,”value”:”0.6 W DC”},{“name”:”Operating Temp. Range”,”normalizedValue”:”-20-50°C”,”value”:”-20-50°C”},{“name”:”Resistance Across Terminals”,”normalizedValue”:”600 kOhm 3-phase; 1.33 kOhm temperature”,”value”:”600 kOhm 3-phase; 1.33 kOhm temperature”},{“name”:”Local Signalling”,”normalizedValue”:”1 LED Green power ON; 1 LED Yellow correct temperature /; 1 LED Yellow phases of relay”,”value”:”1 LED Green power ON; 1 LED Yellow correct temperature (high R1)/(low R2); 1 LED Yellow phases of relay”},{“name”:”Relay Name”,”normalizedValue”:”RM35AT”,”value”:”RM35AT”},{“name”:”Utilisation Category”,”normalizedValue”:”AC-12 IEC 60947-5-1; AC-13 IEC 60947-5-1; AC-14 IEC 60947-5-1; AC-15 IEC 60947-5-1; DC-12 IEC 60947-5-1; DC-13 IEC 60947-5-1; DC-14 IEC 60947-5-1″,”value”:”AC-12 IEC 60947-5-1; AC-13 IEC 60947-5-1; AC-14 IEC 60947-5-1; AC-15 IEC 60947-5-1; DC-12 IEC 60947-5-1; DC-13 IEC 60947-5-1; DC-14 IEC 60947-5-1″},{“name”:”Relay Type”,”normalizedValue”:”control relays”,”value”:”Temperature control relays”},{“name”:”Mounting Support”,”normalizedValue”:”35 mm symmetrical DIN rail conforming to IEC 60715″,”value”:”35 mm symmetrical DIN rail conforming to IEC 60715″},{“name”:”Supply Frequency”,”normalizedValue”:”50/60 Hz +/- 10%”,”value”:”50/60 Hz +/- 10%”},{“name”:”Installed Device”,”normalizedValue”:”Pt 100 probe cable length Less than or Equal to 10 m”,”value”:”Pt 100 probe cable length Less than or Equal to 10 m”},{“name”:”Maximum Power Consumption in VA”,”normalizedValue”:”3.5 VA AC”,”value”:”3.5 VA AC”},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”10 msec”,”value”:”10 ms”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-4 to 122°F”,”value”:”-4 to 122°F (-20 to 50°C)”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”400 V IEC 60664-1″,”value”:”400 V IEC 60664-1″},{“name”:”Connections – Terminals”,”normalizedValue”:”Screw terminals, 1 x 0.5 to 1 x 4 mm² AWG 20 to AWG 11) solid without cable end; Screw terminals, 2 x 0.5 to 2 x 2.5 mm² AWG 20 to AWG 14) solid without cable end; Screw terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 24 to AWG 12) flexible with cable end; Screw terminals, 2 x 0.2 to 2 x 1.5 mm² AWG 24 to AWG 16) flexible with cable end”,”value”:”Screw terminals, 1 x 0.5 to 1 x 4 mm² AWG 20 to AWG 11) solid without cable end; Screw terminals, 2 x 0.5 to 2 x 2.5 mm² AWG 20 to AWG 14) solid without cable end; Screw terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 24 to AWG 12) flexible with cable end; Screw terminals, 2 x 0.2 to 2 x 1.5 mm² AWG 24 to AWG 16) flexible with cable end”},{“name”:”Operating Position”,”normalizedValue”:”Any position without derating”,”value”:”Any position without derating”},{“name”:”Product Certifications”,”normalizedValue”:”CSA, UL, GOST, C-tick, GL”,”value”:”GL; UL; C-tick; CSA; GOST”},{“name”:”Time Delay Range”,”normalizedValue”:”0.1 to 10 s adjustable 0 to 10% of the full scale value)”,”value”:”0.1 to 10 s adjustable 0 to 10% of the full scale value)”},{“name”:”Measurement Accuracy”,”normalizedValue”:”+/- 2°C”,”value”:”+/- 2°C”},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60664-1″,”value”:”3 IEC 60664-1″},{“name”:”Dielectric Test Voltage”,”normalizedValue”:”2 kV AC 50 Hz, 1 min”,”value”:”2 kV AC 50 Hz, 1 min”},{“name”:”Width”,”normalizedValue”:”1.38 in”,”value”:”1.38 in (35 mm)”},{“name”:”Switching Voltage”,”normalizedValue”:”250 V AC/DC”,”value”:”250 V AC/DC”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Indonesia”,”value”:”Indonesia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Relay, 24 to 240V AC/DC Coil Volts, 2 NO, Schneider Electric, Mfr#: RM35ATW5MW”