Description
[{“name”:”Item”,”normalizedValue”:”Power Distribution Block”,”rank”:1,”value”:”Power Distribution Block”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”rank”:2,”value”:”2″},{“name”:”Max. Amps”,”normalizedValue”:”760″,”rank”:3,”value”:”760 A”},{“name”:”Primary Connections/Pole”,”normalizedValue”:”2″,”rank”:4,”value”:”2″},{“name”:”Primary Wire Range (AWG)”,”normalizedValue”:”4 AWG to 500 MCM”,”rank”:5,”value”:”4 AWG to 500 MCM”},{“name”:”Secondary Connection/Pole”,”normalizedValue”:”2″,”rank”:6,”value”:”2″},{“name”:”Secondary Wire Range (AWG)”,”normalizedValue”:”4 AWG to 500 MCM”,”rank”:7,”value”:”4 AWG to 500 MCM”},{“name”:”Power Distribution Block Design”,”normalizedValue”:”Open”,”rank”:9,”value”:”Open”},{“name”:”Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:10,”value”:”600V AC”},{“name”:”Width”,”normalizedValue”:”5.85 in”,”value”:”5.85 in”},{“name”:”Depth”,”normalizedValue”:”3.12 in”,”value”:”3.12 in”},{“name”:”Standards”,”normalizedValue”:”CE Marked, CSA File 70361 Class 6228-1, UL File E60616 Guide XCFR2″,”value”:”CE Marked, CSA File 70361 Class 6228-1, UL File E60616 Guide XCFR2″},{“name”:”Length”,”normalizedValue”:”5-1/2 in”,”value”:”5.5 in”},{“name”:”Length (Straight Wireway)”,”normalizedValue”:”5-1/2 in”,”value”:”5.5 in”},{“name”:”Maximum Current – Copper Conductor”,”normalizedValue”:”760 A”,”value”:”760 A”},{“name”:”For Load Aluminum Wire Size – Maximum”,”normalizedValue”:”500 kcmil”,”value”:”500 kcmil”},{“name”:”Line Connections/Pole”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Special Features”,”normalizedValue”:”18 Months Warranty, Surface Mount”,”value”:”18 Months Warranty, Surface Mount”},{“name”:”For Line Aluminum Wire Size – Minimum”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”For Conductor Material”,”normalizedValue”:”Aluminum, Copper”,”value”:”Aluminum, Copper”},{“name”:”Primary Wire Range”,”normalizedValue”:”4 AWG to 500 kcmil”,”value”:”4 AWG to 500 kcmil”},{“name”:”For Load Copper Wire Size – Maximum”,”normalizedValue”:”500 kcmil”,”value”:”500 kcmil”},{“name”:”Terminal Material”,”normalizedValue”:”Aluminum”,”value”:”Aluminum”},{“name”:”Line Side Connection Type”,”normalizedValue”:”Lug”,”value”:”Lug”},{“name”:”Housing Material”,”normalizedValue”:”Phenolic”,”value”:”Phenolic”},{“name”:”Housing Color”,”normalizedValue”:”Black”,”value”:”Black”},{“name”:”For Load Copper Wire Size – Minimum”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”Load Connections/Pole”,”normalizedValue”:”2″,”value”:”2″},{“name”:”For Line Copper Wire Size – Maximum”,”normalizedValue”:”500 kcmil”,”value”:”500 kcmil”},{“name”:”Overall Width”,”normalizedValue”:”5.88 in”,”value”:”5.88 in”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Load Side Connection Type”,”normalizedValue”:”Lug”,”value”:”Lug”},{“name”:”Overall Depth”,”normalizedValue”:”3.13 in”,”value”:”3.13 in”},{“name”:”For Line Copper Wire Size – Minimum”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”For Load Aluminum Wire Size – Minimum”,”normalizedValue”:”4 AWG”,”value”:”4 AWG”},{“name”:”RoHS Compliant”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Current – Aluminum Conductor”,”normalizedValue”:”620 A”,”value”:”620 A”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”302 deg F”,”value”:”302 Degrees F”},{“name”:”Overall Length”,”normalizedValue”:”5-1/2 in”,”value”:”5.5 in”},{“name”:”Maximum Voltage”,”normalizedValue”:”600 V AC/DC”,”value”:”600 V AC/DC”},{“name”:”Number of Circuits”,”normalizedValue”:”2″,”value”:”2″},{“name”:”For Line Aluminum Wire Size – Maximum”,”normalizedValue”:”500 kcmil”,”value”:”500 kcmil”},{“name”:”Secondary Wire Range”,”normalizedValue”:”4 AWG to 500 MCM”,”value”:”4 AWG to 500 MCM”},{“name”:”Mounting”,”normalizedValue”:”Surface Mount”,”value”:”Surface Mount”},{“name”:”Amps”,”normalizedValue”:”620 (Al conductor), 760 (Cu Conductor)”,”value”:”Al conductor: 620 A; Cu Conductor: 760 A”},{“name”:”Electrical Connection”,”normalizedValue”:”Tin plated Aluminium Lugs”,”value”:”Tin plated Aluminium Lugs”},{“name”:”Features”,”normalizedValue”:”Mercury Free”,”value”:”Mercury Free”},{“name”:”Min. Operating Temp.”,”normalizedValue”:”-40°F”,”value”:”-40°F”},{“name”:”Material”,”normalizedValue”:”Phenolic”,”value”:”Phenolic”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”302°F”,”value”:”302°F”},{“name”:”Wire Strip Length”,”normalizedValue”:”1.38 in (Line), 1.38 in (Load)”,”value”:”Line 1.38 in; Load 1.38 in”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.